Product Details

  • ECLASS 10.0
    27272705
  • ETIM 8.0
    EC002550
  • ETIM 5.0
    EC002550
  • ETIM 7.0
    EC002550
  • ETIM 6.0
    EC002550
  • ETIM 9.0
    EC002550
  • ECLASS 14.0
    27272705
  • ECLASS 5.1.4
    27272705
  • ECLASS 13.0
    27272705
  • ECLASS 8.0
    27272705
  • Customs tariff number
    85365019
  • ECLASS 9.0
    27272705
  • ECLASS 11.0
    27272705
  • US patents
    US 7,656,917 B; US 7,696,468 B; US 8,520,221 B; US 10,304,307B
  • ECLASS 12.0
    27272705
  • Protection class
    III, EN 61140
  • Approvals
    TÜV Süd; c TÜV Süd US; c UL US
  • Test procedure for oscillation in accordance with standard
    EN 60068-2-6
  • Test procedure for continuous shock in accordance with standard
    IEC 60068-2-29
  • Test procedure for EMC in accordance with standard
    DIN 40839-1/3; EN 61496-1
  • Ambient temperature, operation
    0 ... 50 °C
  • Degree of protection
    IP 65
  • Relative humidity (non-condensing)
    15 ... 95 %
  • Type of configuration
    Software Sensor Studio
  • Ambient temperature, storage
    -20 ... 60 °C
  • Type of display
    Alphanumerical display; LED indicator
  • Operational controls
    Software Sensor Studio
  • Dimension (W x H x L)
    140.2 mm x 148.6 mm x 140.3 mm
  • Number of LEDs
    3 Piece(s)
  • Housing color
    Black; Yellow, RAL 1021
  • Housing material
    Metal; Plastic
  • Type of fastening
    Mounting plate; Through-hole mounting; Via optional mounting device
  • Net weight
    3,000 g
  • Metal housing
    Diecast zinc
  • Cable resistance, max.
    15 Ω
  • Supply voltage UB
    24 V, DC, -30 ... 20 %
  • Encoding
    D-coded
  • Lens cover material
    Plastic/PC
  • Type of connection
    Cable with Sub-D
  • No. of pins
    15 -pin
  • Thread size
    M12
  • Cable color
    Black
  • Material
    Metal
  • Cable length
    450 mm
  • Function
    Configuration/parametization; TCP/IP
  • Sheathing material
    PUR
  • Radiated transmitting power
    Max. 4.5 dBm (2.82 mW), class 2
  • Number of connections
    2 Piece(s)
  • Response time
    80 ms, ≥
  • Frequency band
    2,400 ... 2,483.5 MHz
  • Connection
    M12 connector, 4-pin, D-coded
  • Voltage type
    DC
  • Switching voltage low, max.
    2 V
  • Number of signal outputs, configurable
    3 Piece(s)
  • Switching voltage high, min.
    20.8 V
  • Switching current, max.
    300 mA
  • Switching element
    Transistor, PNP
  • Number of safety-related switching outputs (OSSDs)
    2 Piece(s)
  • Power consumption, max.
    17 W, For 24 V, plus output load
  • Scanning angle
    270 °
  • Current consumption (without load), max.
    700 mA, (use power supply unit with 3 A)
  • Light source
    Laser, Infrared
  • Number of field pairs
    1
  • Protective circuit
    Overvoltage protection
  • Object size
    150 mm x 150 mm
  • Operating range
    0 ... 4.5 m
  • Transmitted-signal shape
    Pulsed
  • Laser class
    1, IEC/EN 60825-1:2014
  • Wavelength
    905 nm
  • Angular resolution
    0.1 °
  • Repetition frequency
    90 kHz
  • Diffuse reflection, min.
    1.8 %
  • Resolution (adjustable)
    30/40/50/60/70/150 mm
  • Number of field pairs, switchable
    1
  • Number of quads, switchable
    1
  • Minimum adjustable range
    50 mm
  • Application
    Mobile danger zone guarding; Mobile side guarding; Stationary access guarding; Stationary danger zone guarding
  • SILCL
    2, IEC/EN 62061
  • Number of independent sensor configurations
    1
  • Number of protective functions
    1 Piece(s)
  • Functions
    Four-field mode
  • Mission time
    20 years, EN ISO 13849-1
  • PFHD
    9E-08 per hour
  • Performance Level (PL)
    d, EN ISO 13849-1
  • Category
    3, EN ISO 13849
  • SIL
    2, IEC 61508
  • Special version
    RS4 substitute
  • Type
    3, IEC/EN 61496
  • Series
    RSL 400
  • Restart
    Start/restart interlock (RES), selectable

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


RSL410-M/CU411-RS4 Description

RSL410-M/CU411-RS4 Leuze - Safety laser scanner



Related documents RSL410-M/CU411-RS4 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Leuze

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Leuze Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Leuze Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Leuze, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo