Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

8058475 Festo Flow Sensors

Festo 8058475 flow sensor SFAH-100U-Q8S-PNLK-PNVBA-M8 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL
Festo

Part#:8058475

Manufacturer:Festo

Alt. Part#:SFAH-100U-Q8S-PNLK-PNVBA-M8

Product Lifecycle:Active

Get a quick Quote!

flow sensor SFAH-100U-Q8S-PNLK-PNVBA-M8 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8058475 Festo price in the box on the right side or send a quick quote.

Product Details

  • KC characters
    KC EMC
  • Electrical connection 1, number of pins/wires
    4
  • Measuring principle
    Thermal
  • Accuracy of flow rate
    ± (2% o.m.v. + 1% FS)
  • Temperature co-efficient margin in ± %FS/K
    typ. 0.15% FS/K
  • Min. load resistance of voltage output
    20 kOhm
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, process data content IN
    1 bit BDC (volume monitoring) 2 bit BDC (flow monitoring)
  • IO-Link®, minimum cycle time
    4 ms
  • Product weight
    60 g
  • Housing material
    PA-reinforced
  • Pressure drop
    15 mbar
  • Corrosion resistance class (CRC)
    2 - Moderate corrosion stress
  • Electrical connection for input 1, connection pattern
    00991171
  • Idle current
    ≤ 25 mA
  • Measured variable
    Mass flow rate Volumetric flow rate
  • Flow measuring range end value
    100 l/min
  • Temperature of medium
    0 °C ... 50 °C
  • Nominal temperature
    23 °C
  • Max. output current
    100 mA
  • Flow characteristic curve, start value
    0 l/min
  • Protocol
    IO-Link®
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, port class
    A
  • IO-Link®, service data contents IN
    32 bit volume/mass measurement
  • Pneumatic connection
    For pneumatic tubing outside diameter 8 mm
  • Materials in contact with the media
    Wrought aluminum alloy, anodized High-alloy stainless steel
  • Degree of protection
    IP40
  • Protection class
    III
  • Protection against tampering
    IO-Link® PIN code
  • Symbol
    00995794
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Method of measurement
    Heat transfer
  • Ambient temperature
    0 °C ... 50 °C
  • Repetition accuracy margin in ± %FS
    0.8 %FS
  • Analog output
    0 - 10 V 1 - 5 V
  • Display type
    Illuminated LCD, multi-color
  • Type code
    SFAH
  • Electrical connection 1, connection type
    Plug
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Certificate issuing authority
    UL E322346
  • Flow direction
    Unidirectional
  • Operating pressure
    -0.9 bar ... 10 bar
  • Zero point repetition accuracy in ± %FS
    0.2 %FS
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Switching function
    Window comparator Auto difference monitoring
  • Flow characteristic curve, end value
    100 l/min
  • Short-circuit protection
    yes
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, process data width IN
    3 Byte
  • DC operating voltage range
    22 V ... 26 V
  • Type of mounting
    With accessories
  • Setting options
    IO-Link® Via display and pushbuttons
  • Pneumatic connection, outlet direction
    Straight
  • Electrical connection 1, connection technology
    M8x1 A-coded as per EN 61076-2-104
  • Note on materials
    RoHS-compliant
  • Flow measuring range start value
    2 l/min
  • Operating medium
    Argon Nitrogen
  • Pressure influence of margin in ±%FS/bar
    1 %FS/b.
  • Switching element function
    N/C contact/N/O contact switchable
  • Max. load resistance of current output
    500 Ohm
  • Overload protection
    Available
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, data memory required
    < 500 byte
  • Mounting position
    Any
  • Reverse polarity protection
    for all electrical connections
  • Displayable unit(s)
    g scft/min

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents 8058475 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Festo

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Festo Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Festo Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Festo, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo