5340822 Festo Servo Amplifiers

Festo 5340822 servo drive CMMT-AS-C3-11A-P3-EC-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 2100 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB
Festo

Part#:5340822

Manufacturer:Festo

Alt. Part#:CMMT-AS-C3-11A-P3-EC-S1

Product Lifecycle:Active

Get a quick Quote!

servo drive CMMT-AS-C3-11A-P3-EC-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 2100 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB

About the manufacturer: Festo is one of the manufacturers that offers Servo Amplifiers that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5340822 Festo price in the box on the right side or send a quick quote.

Product Details

  • Ethernet interface, protocol
    TCP/IP
  • Encoder interface 2, function
    Incremental encoder SIN/COS encoder
  • Number of high-speed switching outputs
    2
  • Max. output current of holding brake
    1 A
  • Number of safe 2-pin inputs
    2
  • Based on norm
    EN 50581 EN 62061
  • Line filter
    Integrated
  • Performance Level (PL)
    Safe brake control (SBC)/category 3, performance level e Safe torque off (STO)/category 4, performance level e
  • Output voltage range AC
    3x (0 – input) V
  • Input voltage range AC
    200 V ... 480 V
  • Nominal voltage, logic supply DC
    24 V
  • SFF safe failure fraction
    99 %
  • Peak current, load supply
    9 A
  • Contamination level
    2
  • Max. current consumption for logic supply with clamping brake and I/O
    2.3 A
  • Note on ambient temperature
    Above an ambient temperature of 40 °C, the power must be reduced by 3%/°C.
  • Number of digital logic outputs 24 V DC
    6
  • Work range of logic input
    -3 V ... 30 V
  • Characteristics of setpoint inputs
    Differential inputs Configurable for current/force
  • Switching logic at outputs
    PNP (positive switching)
  • Type code
    CMMT-AS
  • Ethernet interface, function
    Parameterization and commissioning
  • Fieldbus interface, protocol
    EtherCAT
  • Max. current of the floating switching outputs
    50 mA
  • Braking resistor nominal power (IEC)
    48 W
  • Conforms to standard
    EN 61800-3 EN ISO 13849-1
  • Safety function
    Safe brake control (SBC) Safe stop 1 (SS1)
  • Braking resistor, integrated
    130 Ohm
  • Characteristics of digital logic outputs
    Freely configurable in some cases Diagnostic outputs in some cases
  • Max. peak current duration
    2 s
  • Nominal current load supply
    3 A
  • Nominal operating voltage phases
    3-phase
  • Peak current per phase, effective
    7.5 A
  • Max. current consumption for logic supply without clamping brake
    0.5 A
  • Permissible range of logic voltage
    ± 20 %
  • Relative air humidity
    5 - 90 % Non-condensing
  • Product weight
    2100 g
  • Number of digital logic inputs
    12
  • Work range of setpoint input
    ± 10 V
  • Encoder interface input, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Characteristics of logic input
    Freely configurable in some cases Not galvanically isolated
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • KC characters
    KC EMC
  • Fieldbus interface, connection technology
    RJ45
  • Fieldbus interface, connection type
    2x socket
  • Number of diagnostic outputs
    2
  • Number of high-speed logic inputs
    2
  • Pulse energy for braking resistor
    850 Ws
  • Time resolution of high-speed logic inputs
    1 µs
  • Time resolution of high-speed switching outputs
    1 µs
  • Mode of operation
    Field-oriented regulation 1x SYNC interface for encoder emulation or encoder input
  • Safety integrity level (SIL)
    Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3
  • Control elements
    Optional: CDSB operating unit
  • Diagnostic coverage
    97 %
  • Pulse power of braking resistor
    5 kVA
  • Max. DC link voltage
    800 V
  • Nominal voltage, load supply DC
    560 V
  • Mains frequency
    48 Hz ... 62 Hz
  • Surge resistance
    6 kV
  • Load supply permissible range
    ± 10 %
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Logic input specification
    Based on IEC 61131-2, type 3
  • Operating range of analog inputs
    ± 10 V
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • Fieldbus interface, function
    Bus connection, incoming/forwarding EtherCAT® slave
  • Information on max. installation height
    1% power reduction/100 m above 1000 m.
  • Protection class
    I
  • Synchronization interface, function
    Encoder emulation A/B/Z Encoder input A/B/Z
  • Number of inputs for motor temperature sensor
    1
  • System voltage to EN 61800-5-1
    300 V
  • Max. voltage drop from logic supply to brake output
    0.8 V
  • Max. current consumption for logic supply with parking brake
    1.5 A
  • Controller operating mode
    Cascade control Autotuning
  • Output frequency
    0 Hz ... 599 Hz
  • Impedance of setpoint input
    70 kOhm
  • Max. current of digital logic outputs
    20 mA
  • Nominal operating voltage AC
    400 V
  • Degree of protection
    IP20
  • UL-ambient temperature
    0 °C ... 40 °C
  • Communication profile
    CiA402 FoE (File over EtherCAT)
  • Process interfacing
    I/O mode for 256 positioning blocks Interpolated mode CSV
  • Input switching logic
    PNP (positive switching)
  • Type of mounting
    Mounting plate, screwed on
  • Mounting position
    Free convection Vertical
  • Encoder interface, function
    EnDat® 2.1 encoder SIN/COS encoder
  • Mains types
    TN IT
  • Overvoltage category
    III
  • Number of floating switching outputs
    1
  • Max. continuous output of the external braking resistor (IEC)
    600 W
  • Max. short circuit protection of mains
    10 kA
  • Max. installation height
    2000 m
  • Active PFC
    no
  • Display
    LED green/yellow/red
  • Braking resistor, external
    130 Ohm ... 250 Ohm
  • Hardware fault tolerance
    1
  • Max. length of motor cable without ext. mains filter
    50 m
  • Controller nominal power
    1200 VA
  • Nominal current per phase, effective
    2.5 A
  • Peak power
    3600 VA
  • Permissible voltage fluctuations
    +/- 10 %
  • Certificate issuing authority
    German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 UL E331130
  • Storage temperature
    -25 °C ... 55 °C
  • Ambient temperature
    0 °C ... 50 °C
  • Number of analog setpoint inputs
    1
  • Encoder interface output, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Fieldbus coupling
    EtherCAT

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents 5340822 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Festo

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Festo Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Festo Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Festo, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo