Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

5340820 Festo Servo Amplifiers

Festo 5340820 servo drive CMMT-AS-C4-3A-EC-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1400 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB
Festo

Part#:5340820

Manufacturer:Festo

Alt. Part#:CMMT-AS-C4-3A-EC-S1

Product Lifecycle:Active

Get a quick Quote!

About the product: servo drive CMMT-AS-C4-3A-EC-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1400 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB

About the manufacturer: Festo is one of the manufacturers that offers Servo Amplifiers that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5340820 Festo price in the box on the right side or send a quick quote.

5340820 Product Details

  • Peak power
    2000 VA
  • Max. DC link voltage
    395 V
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Protection class
    I
  • Synchronization interface, function
    Encoder emulation A/B/Z Encoder input A/B/Z
  • Max. current of the floating switching outputs
    50 mA
  • Max. output current of holding brake
    1 A
  • Braking resistor nominal power (IEC)
    23 W
  • Based on norm
    EN 50581 EN 62061
  • Controller operating mode
    Cascade control Autotuning
  • Safety function
    Safe brake control (SBC) Safe stop 1 (SS1)
  • Output voltage range AC
    3x (0 – input) V
  • Max. current of digital logic outputs
    20 mA
  • Encoder interface, function
    EnDat® 2.1 encoder SIN/COS encoder
  • Ethernet interface, protocol
    TCP/IP
  • Fieldbus interface, protocol
    EtherCAT
  • Number of high-speed switching outputs
    2
  • Max. continuous output of the external braking resistor (IEC)
    350 W
  • System voltage to EN 61800-5-1
    300 V
  • Time resolution of high-speed switching outputs
    1 µs
  • Mode of operation
    Field-oriented regulation 1x SYNC interface for encoder emulation or encoder input
  • Output frequency
    0 Hz ... 599 Hz
  • Hardware fault tolerance
    1
  • Max. peak current duration
    2 s
  • Nominal voltage, logic supply DC
    24 V
  • Nominal operating voltage phases
    1-phase
  • Surge resistance
    6 kV
  • Permissible voltage fluctuations
    -20 % / +15 %
  • Degree of protection
    IP20
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Number of digital logic inputs
    12
  • Operating range of analog inputs
    ± 10 V
  • Encoder interface input, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Mounting position
    Free convection Vertical
  • Fieldbus interface, connection technology
    RJ45
  • Encoder interface 2, function
    Incremental encoder SIN/COS encoder
  • Number of inputs for motor temperature sensor
    1
  • Number of high-speed logic inputs
    2
  • Number of safe 2-pin inputs
    2
  • Max. installation height
    2000 m
  • Performance Level (PL)
    Safe brake control (SBC)/category 3, performance level e Safe torque off (STO)/category 4, performance level e
  • Braking resistor, integrated
    100 Ohm
  • Impedance of setpoint input
    70 kOhm
  • Nominal operating voltage AC
    230 V
  • Nominal voltage, load supply DC
    320 V
  • Mains frequency
    48 Hz ... 62 Hz
  • Peak current per phase, effective
    12 A
  • Contamination level
    2
  • Certificate issuing authority
    German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 UL E331130
  • UL-ambient temperature
    0 °C ... 40 °C
  • Communication profile
    CiA402 FoE (File over EtherCAT)
  • Process interfacing
    I/O mode for 256 positioning blocks Interpolated mode CSV
  • Characteristics of logic input
    Freely configurable in some cases Not galvanically isolated
  • Type of mounting
    Mounting plate, screwed on
  • Fieldbus interface, function
    Bus connection, incoming/forwarding EtherCAT® slave
  • Information on max. installation height
    1% power reduction/100 m above 1000 m.
  • Ethernet interface, function
    Parameterization and commissioning
  • Fieldbus interface, connection type
    2x socket
  • Number of diagnostic outputs
    2
  • Pulse energy for braking resistor
    230 Ws
  • Max. short circuit protection of mains
    100 kA
  • Max. current consumption for logic supply with parking brake
    1.5 A
  • Conforms to standard
    EN 61800-3 EN ISO 13849-1
  • Safety integrity level (SIL)
    Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3
  • Braking resistor, external
    67 Ohm ... 100 Ohm
  • Diagnostic coverage
    97 %
  • Pulse power of braking resistor
    1.6 kVA
  • Controller nominal power
    700 VA
  • Nominal current per phase, effective
    4 A
  • Peak current, load supply
    16.8 A
  • Max. current consumption for logic supply without clamping brake
    0.5 A
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Relative air humidity
    5 - 90 % Non-condensing
  • Ambient temperature
    0 °C ... 50 °C
  • Work range of logic input
    -3 V ... 30 V
  • Logic input specification
    Based on IEC 61131-2, type 3
  • Switching logic at outputs
    PNP (positive switching)
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • Type code
    CMMT-AS
  • KC characters
    KC EMC
  • Mains types
    TT IT
  • Overvoltage category
    III
  • Number of floating switching outputs
    1
  • Max. voltage drop from logic supply to brake output
    0.8 V
  • Time resolution of high-speed logic inputs
    1 µs
  • Active PFC
    no
  • Line filter
    Integrated
  • Display
    LED green/yellow/red
  • Control elements
    Optional: CDSB operating unit
  • Characteristics of digital logic outputs
    Freely configurable in some cases Diagnostic outputs in some cases
  • Max. length of motor cable without ext. mains filter
    25 m
  • Nominal current load supply
    5.6 A
  • Input voltage range AC
    100 V ... 230 V
  • SFF safe failure fraction
    99 %
  • Max. current consumption for logic supply with clamping brake and I/O
    2.3 A
  • Load supply permissible range
    -20 %/+15 %
  • Storage temperature
    -25 °C ... 55 °C
  • Product weight
    1400 g
  • Number of digital logic outputs 24 V DC
    6
  • Work range of setpoint input
    ± 10 V
  • Characteristics of setpoint inputs
    Differential inputs Configurable for current/force
  • Fieldbus coupling
    EtherCAT
  • Permissible range of logic voltage
    ± 20 %
  • Note on ambient temperature
    Above an ambient temperature of 40 °C, the power must be reduced by 3%/°C.
  • Number of analog setpoint inputs
    1
  • Encoder interface output, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Input switching logic
    PNP (positive switching)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 5340820 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

5340820

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo