Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

5340819 Festo Servo Amplifiers

Festo 5340819 servo drive CMMT-AS-C2-3A-EC-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1300 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB
Festo

Part#:5340819

Manufacturer:Festo

Alt. Part#:CMMT-AS-C2-3A-EC-S1

Product Lifecycle:Active

Get a quick Quote!

About the product: servo drive CMMT-AS-C2-3A-EC-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1300 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB

About the manufacturer: Festo is one of the manufacturers that offers Servo Amplifiers that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5340819 Festo price in the box on the right side or send a quick quote.

5340819 Product Details

  • Mounting position
    Free convection Vertical
  • Encoder interface, function
    EnDat® 2.1 encoder SIN/COS encoder
  • Protection class
    I
  • Synchronization interface, function
    Encoder emulation A/B/Z Encoder input A/B/Z
  • Fieldbus interface, connection type
    2x socket
  • Pulse energy for braking resistor
    230 Ws
  • System voltage to EN 61800-5-1
    300 V
  • Based on norm
    EN 50581 EN 62061
  • Safety function
    Safe brake control (SBC) Safe stop 1 (SS1)
  • Performance Level (PL)
    Safe brake control (SBC)/category 3, performance level e Safe torque off (STO)/category 4, performance level e
  • Characteristics of digital logic outputs
    Freely configurable in some cases Diagnostic outputs in some cases
  • Hardware fault tolerance
    1
  • Type code
    CMMT-AS
  • Ethernet interface, protocol
    TCP/IP
  • Fieldbus interface, protocol
    EtherCAT
  • Number of floating switching outputs
    1
  • Number of diagnostic outputs
    2
  • Max. voltage drop from logic supply to brake output
    0.8 V
  • Number of safe 2-pin inputs
    2
  • Max. installation height
    2000 m
  • Controller operating mode
    Cascade control Autotuning
  • Line filter
    Integrated
  • Output voltage range AC
    3x (0 – input) V
  • Max. current of digital logic outputs
    20 mA
  • Max. DC link voltage
    395 V
  • Nominal voltage, load supply DC
    320 V
  • Nominal operating voltage phases
    1-phase
  • Max. current consumption for logic supply with clamping brake and I/O
    2.3 A
  • Storage temperature
    -25 °C ... 55 °C
  • Product weight
    1300 g
  • Process interfacing
    I/O mode for 256 positioning blocks Interpolated mode CSV
  • Characteristics of setpoint inputs
    Differential inputs Configurable for current/force
  • Fieldbus coupling
    EtherCAT
  • KC characters
    KC EMC
  • Fieldbus interface, connection technology
    RJ45
  • Encoder interface 2, function
    Incremental encoder SIN/COS encoder
  • Number of high-speed switching outputs
    2
  • Max. current of the floating switching outputs
    50 mA
  • Number of high-speed logic inputs
    2
  • Max. current consumption for logic supply with parking brake
    1.5 A
  • Active PFC
    no
  • Control elements
    Optional: CDSB operating unit
  • Braking resistor, integrated
    100 Ohm
  • Max. peak current duration
    2 s
  • Controller nominal power
    350 VA
  • Mains frequency
    48 Hz ... 62 Hz
  • Max. current consumption for logic supply without clamping brake
    0.5 A
  • Certificate issuing authority
    German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 UL E331130
  • Ambient temperature
    0 °C ... 50 °C
  • Number of digital logic outputs 24 V DC
    6
  • Encoder interface output, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Max. output current of holding brake
    1 A
  • Max. short circuit protection of mains
    100 kA
  • Time resolution of high-speed switching outputs
    1 µs
  • Safety integrity level (SIL)
    Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3
  • Output frequency
    0 Hz ... 599 Hz
  • Braking resistor, external
    100 Ohm ... 160 Ohm
  • Pulse power of braking resistor
    1.6 kVA
  • Input voltage range AC
    100 V ... 230 V
  • Nominal current per phase, effective
    2 A
  • SFF safe failure fraction
    99 %
  • Surge resistance
    6 kV
  • Contamination level
    2
  • Permissible range of logic voltage
    ± 20 %
  • Relative air humidity
    5 - 90 % Non-condensing
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Number of digital logic inputs
    12
  • Work range of logic input
    -3 V ... 30 V
  • Characteristics of logic input
    Freely configurable in some cases Not galvanically isolated
  • Input switching logic
    PNP (positive switching)
  • Fieldbus interface, function
    Bus connection, incoming/forwarding EtherCAT® slave
  • Information on max. installation height
    1% power reduction/100 m above 1000 m.
  • Ethernet interface, function
    Parameterization and commissioning
  • Mains types
    TT IT
  • Overvoltage category
    III
  • Number of inputs for motor temperature sensor
    1
  • Max. continuous output of the external braking resistor (IEC)
    180 W
  • Braking resistor nominal power (IEC)
    23 W
  • Time resolution of high-speed logic inputs
    1 µs
  • Conforms to standard
    EN 61800-3 EN ISO 13849-1
  • Mode of operation
    Field-oriented regulation 1x SYNC interface for encoder emulation or encoder input
  • Display
    LED green/yellow/red
  • Diagnostic coverage
    97 %
  • Impedance of setpoint input
    70 kOhm
  • Max. length of motor cable without ext. mains filter
    25 m
  • Nominal operating voltage AC
    230 V
  • Nominal voltage, logic supply DC
    24 V
  • Peak power
    1000 VA
  • Peak current, load supply
    8.4 A
  • Permissible voltage fluctuations
    -20 % / +15 %
  • Note on ambient temperature
    Above an ambient temperature of 40 °C, the power must be reduced by 3%/°C.
  • UL-ambient temperature
    0 °C ... 40 °C
  • Communication profile
    CiA402 FoE (File over EtherCAT)
  • Work range of setpoint input
    ± 10 V
  • Operating range of analog inputs
    ± 10 V
  • Type of mounting
    Mounting plate, screwed on
  • Nominal current load supply
    2.8 A
  • Peak current per phase, effective
    6 A
  • Load supply permissible range
    -20 %/+15 %
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Degree of protection
    IP20
  • Number of analog setpoint inputs
    1
  • Logic input specification
    Based on IEC 61131-2, type 3
  • Encoder interface input, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Switching logic at outputs
    PNP (positive switching)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 5340819 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

5340819

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo