5340815 Festo Servo Amplifiers

Festo 5340815 servo drive CMMT-AS-C4-3A-PN-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1400 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB
Festo

Part#:5340815

Manufacturer:Festo

Alt. Part#:CMMT-AS-C4-3A-PN-S1

Product Lifecycle:Active

Get a quick Quote!

servo drive CMMT-AS-C4-3A-PN-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1400 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB

About the manufacturer: Festo is one of the manufacturers that offers Servo Amplifiers that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5340815 Festo price in the box on the right side or send a quick quote.

Product Details

  • Ethernet interface, protocol
    TCP/IP
  • Encoder interface 2, function
    Incremental encoder SIN/COS encoder
  • Number of high-speed switching outputs
    2
  • Max. continuous output of the external braking resistor (IEC)
    350 W
  • Braking resistor nominal power (IEC)
    23 W
  • Max. current consumption for logic supply with parking brake
    1.5 A
  • KC characters
    KC EMC
  • Fieldbus interface, connection technology
    RJ45
  • Number of floating switching outputs
    1
  • Max. current of the floating switching outputs
    50 mA
  • Pulse energy for braking resistor
    230 Ws
  • Max. voltage drop from logic supply to brake output
    0.8 V
  • Time resolution of high-speed switching outputs
    1 µs
  • Controller operating mode
    Cascade control Autotuning
  • Safety integrity level (SIL)
    Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3
  • Braking resistor, integrated
    100 Ohm
  • Hardware fault tolerance
    1
  • Max. peak current duration
    2 s
  • Input voltage range AC
    100 V ... 230 V
  • Nominal current load supply
    5.6 A
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Information on max. installation height
    1% power reduction/100 m above 1000 m.
  • Mains types
    TT IT
  • Overvoltage category
    III
  • Number of diagnostic outputs
    2
  • System voltage to EN 61800-5-1
    300 V
  • Number of safe 2-pin inputs
    2
  • Based on norm
    EN 50581 EN 62061
  • Mode of operation
    Field-oriented regulation 1x SYNC interface for encoder emulation or encoder input
  • Output frequency
    0 Hz ... 599 Hz
  • Impedance of setpoint input
    70 kOhm
  • Nominal voltage, logic supply DC
    24 V
  • SFF safe failure fraction
    99 %
  • Max. current consumption for logic supply without clamping brake
    0.5 A
  • Permissible voltage fluctuations
    -20 % / +15 %
  • Note on ambient temperature
    Above an ambient temperature of 40 °C, the power must be reduced by 3%/°C.
  • Number of digital logic outputs 24 V DC
    6
  • Logic input specification
    Based on IEC 61131-2, type 3
  • Encoder interface output, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Type code
    CMMT-AS
  • Ethernet interface, function
    Parameterization and commissioning
  • Encoder interface, function
    EnDat® 2.1 encoder SIN/COS encoder
  • Synchronization interface, function
    Encoder emulation A/B/Z Encoder input A/B/Z
  • Number of inputs for motor temperature sensor
    1
  • Max. output current of holding brake
    1 A
  • Number of high-speed logic inputs
    2
  • Time resolution of high-speed logic inputs
    1 µs
  • Conforms to standard
    EN 61800-3 EN ISO 13849-1
  • Line filter
    Integrated
  • Display
    LED green/yellow/red
  • Braking resistor, external
    67 Ohm ... 100 Ohm
  • Characteristics of digital logic outputs
    Freely configurable in some cases Diagnostic outputs in some cases
  • Pulse power of braking resistor
    1.6 kVA
  • Max. DC link voltage
    395 V
  • Nominal voltage, load supply DC
    320 V
  • Nominal operating voltage phases
    1-phase
  • Peak current per phase, effective
    12 A
  • Contamination level
    2
  • Storage temperature
    -25 °C ... 55 °C
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Number of analog setpoint inputs
    1
  • Work range of logic input
    -3 V ... 30 V
  • Encoder interface input, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Switching logic at outputs
    PNP (positive switching)
  • Fieldbus interface, function
    Bus connection, incoming/forwarding PROFINET slave
  • Mounting position
    Free convection Vertical
  • Protection class
    I
  • Fieldbus interface, protocol
    PROFINET IRT PROFINET RT
  • Fieldbus interface, connection type
    2x socket
  • Max. short circuit protection of mains
    100 kA
  • Max. installation height
    2000 m
  • Safety function
    Safe brake control (SBC) Safe stop 1 (SS1)
  • Control elements
    Optional: CDSB operating unit
  • Diagnostic coverage
    97 %
  • Max. current of digital logic outputs
    20 mA
  • Nominal operating voltage AC
    230 V
  • Mains frequency
    48 Hz ... 62 Hz
  • Surge resistance
    6 kV
  • Load supply permissible range
    -20 %/+15 %
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Degree of protection
    IP20
  • Number of digital logic inputs
    12
  • Operating range of analog inputs
    ± 10 V
  • Characteristics of logic input
    Freely configurable in some cases Not galvanically isolated
  • Type of mounting
    Mounting plate, screwed on
  • Active PFC
    no
  • Performance Level (PL)
    Safe brake control (SBC)/category 3, performance level e Safe torque off (STO)/category 4, performance level e
  • Output voltage range AC
    3x (0 – input) V
  • Max. length of motor cable without ext. mains filter
    25 m
  • Controller nominal power
    700 VA
  • Nominal current per phase, effective
    4 A
  • Peak power
    2000 VA
  • Permissible range of logic voltage
    ± 20 %
  • Relative air humidity
    5 - 90 % Non-condensing
  • Ambient temperature
    0 °C ... 50 °C
  • UL-ambient temperature
    0 °C ... 40 °C
  • Process interfacing
    AC1: Adjustable-Speed Drives AC4: Synchronous Servo Application
  • Input switching logic
    PNP (positive switching)
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • Peak current, load supply
    16.8 A
  • Max. current consumption for logic supply with clamping brake and I/O
    2.3 A
  • Certificate issuing authority
    German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 UL E331130
  • Product weight
    1400 g
  • Communication profile
    PROFIdrive PROFIenergy
  • Work range of setpoint input
    ± 10 V
  • Characteristics of setpoint inputs
    Differential inputs Configurable for current/force
  • Fieldbus coupling
    PROFINET

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents 5340815 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Festo

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Festo Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Festo Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Festo, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo