X20CP1301 B&R Electronic Components
Part#:X20CP1301
Manufacturer:B&R
Product Lifecycle:Active
Get a quick Quote!
X20 PLC, with integrated I/O, x86-200, 128 MB DDR3 RAM, 16 kB FRAM, 1 GB onboard flash drive, 1 insert slot for X20 interface modules, 1 USB interface, 1 RS232 interface, 1 Ethernet interface 10/100BASE-T, 14 digital inputs, 24 VDC, sink, 4 digital inputs
Check out the X20CP1301 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight300 g
- Temperature Operation Vertical mounting orientation -25 to 50°C
- Temperature Operation Horizontal mounting orientation -25 to 60°C
- Max. error Current Offset 0 to 20 mA = 0.1% (Rev.
- Max. error Voltage Gain
0.18% (Rev.- Max. error Current Gain
0 to 20 mA = 0.15% (Rev.- Max. error Voltage Offset
0.04% (Rev.- Interface IF2 Transfer Auto-MDI/MDIX
Yes- Interface IF2 Transfer Autonegotiation
Yes- Interface IF2 Transfer Full-duplex
Yes- Interface IF2 Transfer Physical layer
10BASE-T/100BASE-TX- Interface IF2 Transfer Half-duplex
Yes- Application memory Writable data amount Results for 5 years
21.9 GB/day- Processor L1 cache Program code
16 kB- Application memory Writable data amount Guaranteed
40 TB- Processor L1 cache Data code
16 kB- Dimensions Height
99 mm- Dimensions Depth
75 mm- Dimensions Width
164 mm- Relative humidity Storage
5 to 95%, non-condensing- Relative humidity Transport
5 to 95%, non-condensing- Relative humidity Operation
5 to 95%, non-condensing- Temperature Transport
-40 to 85°C- Temperature Derating
See section "Switching frequency derating for high-speed digital outputs".- Temperature Storage
-40 to 85°C- Installation elevation above sea level >2000 m
Reduction of ambient temperature by 0.5°C per 100 m- Mounting orientation Horizontal
Yes- Installation elevation above sea level 0 to 2000 m
No limitation- Mounting orientation Vertical
Yes- Switching frequency Inductive load
See section "Switching inductive loads".- Switching frequency Resistive load
Standard outputs and mixed channels: Max. 500 Hz; High-speed outputs: 50 kHz, max. 200 kHz (see section "Switching frequency derating for high-speed digital outputs")- Switching delay 1 → 0
Standard outputs and mixed channels: <300 µs; High-speed outputs: <3 µs- Switching delay 0 → 1
Standard outputs and mixed channels: <300 µs; High-speed outputs: <3 µs- Pulse width modulation Resolution for pulse duration
0.1% of the configured frequency- Temperature sensor normalization Pt1000
-200 to 850°C- Pulse width modulation Pulse duration
0 to 100%, minimum 2.5 µs- Pulse width modulation Period duration
5 to 65535 µs corresponds to 200 kHz to 15 Hz- Max. error at 25°C Offset
0.15% (Rev.- Max. error at 25°C Gain
0.3% (Rev.- Sensor Pt1000
-200 to 850°C- Nonlinearity Voltage
<0.025%- Nonlinearity Current
<0.05%- Common-mode rejection 50 Hz
70 dB- Common-mode rejection DC
70 dB- Max. offset drift Current
0 to 20 mA = 0.008 %/°C / 4 to 20 mA = 0.012 %/°C- Max. offset drift Voltage
0.008 %/°C- Max. gain drift Current
0 to 20 mA = 0.015 %/°C / 4 to 20 mA = 0.023 %/°C- Permissible input signal Current
Max. ±50 mA- Max. gain drift Voltage
0.017 %/°C- Permissible input signal Voltage
Max. ±30 V- Load Voltage
-- Input impedance in signal range Current
-- Load Current
<300 Ω- Input impedance in signal range Voltage
20 MΩ- Output format Current
INT 0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.883 μA- Output format Voltage
INT 0x8001 - 0x7FFF / 1 LSB = 0x0008 = 2.441 mV- Digital converter resolution Current
12-bit- Output format Data type
INT- Digital converter resolution Voltage
±12-bit- Switching threshold High
>15 VDC- Switching threshold Low
<5 VDC- Input filter Software
Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments- Interface IF4 Max. output current
0.5 A- Input filter Hardware
Standard inputs and mixed channels: ≤200 μs; High-speed inputs: ≤2 μs, when used as standard inputs: ≤200 μs- Interface IF6 Fieldbus
X2X Link master- Interface IF4 Variant
Type A- Interface IF2 Line length
Max. 100 m between 2 stations (segment length)- Interface IF4 Type
USB 1.1/2.0- Interface IF2 Transfer rate
10/100 Mbit/s- Interface IF2 Variant
1x RJ45 shielded- Interface IF2 Signal
Ethernet- Interface IF1 Transfer rate
Max. 115.2 kbit/s- Interface IF1 Max. distance
900 m- Interface IF1 Signal
RS232- Interface IF1 Variant
Connection via 16-pin terminal block X20TB1F- Application memory Error-correcting code (ECC)
Yes- Application memory Guaranteed erase/write cycles
20,000- Application memory Type
1 GB eMMC flash memory- Application memory Data retention
10 years- Standard memory RAM
128 MB DDR3 SDRAM- Processor L2 cache
128 kB- Processor Clock frequency
200 MHz- Certifications ABS
Yes- Certifications EAC
Yes- Processor Type
Vx86EX- Certifications LR
ENV1- Certifications KR
Yes- Certifications DNV
Temperature: B (0 - 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)- Certifications HazLoc
cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5- Certifications UL
cULus E115267; Industrial control equipment- Certifications ATEX
Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X- Certifications UKCA
Yes- Support Visual Components support
Yes- Certifications CE
Yes- Power consumption Internal I/O
2.3 W- Support Controller redundancy
No- Support ACOPOS support
Yes- Support reACTION-capable I/O channels
No- Diagnostics RS232 data transfer
Yes, using LED status indicator- Diagnostics I/O power supply
Yes, using LED status indicator- Diagnostics Temperature
Yes, using software register- Diagnostics Supply voltage monitoring
Yes, using LED status indicator- Diagnostics Ethernet
Yes, using LED status indicator- Diagnostics CPU function
Yes, using LED status indicator- Diagnostics Inputs
Analog inputs: Yes, using LED status indicator and software- Diagnostics Outputs
Digital outputs: Yes, using LED status indicator and software (output error status)- Note
X20 end cover plate (right) included in delivery; 3 X20 terminal blocks (16-pin) included in delivery; Interface module slot cover included in delivery- Electrical isolation
Ethernet (IF2) and X2X (IF6) isolated from each other, from other interfaces and from PLC; Channel isolated from bus; Channel not isolated from channel or PLC- Braking voltage when switching off inductive loads
Standard outputs and mixed channels: Typ. 45 VDC- Switch-on in the event of overload shutdown or short-circuit shutdown
Standard outputs and mixed channels: Approx. 10 ms (depends on module temperature); High-speed outputs: No switch-on- Degree of protection per EN 60529
IP20- Residual voltage
Standard outputs and mixed channels: <0.1 V at nominal current 0.5 A; High-speed outputs: <0.9 V at nominal current 0.1 A- Peak short-circuit current
Standard outputs and mixed channels: <3 A; High-speed outputs: <20 A- Leakage current when the output is switched off
Standard outputs and mixed channels: 5 µA; High-speed outputs: 25 µA- RDS(on)
140 mΩ- Output protection
Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current"); Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")- Diagnostic status
Standard outputs and mixed channels: Output monitoring with 10 ms delay; High-speed outputs: Output monitoring with 10 µs delay- Output circuit
Standard outputs and mixed channels: Source; High-speed outputs: Sink or source- Nominal output current
Standard outputs and mixed channels: 0.5 A; High-speed outputs: 0.2 A- Standardized range of values for resistance measurement
0.1 to 4000.0 Ω- Total nominal current
Standard outputs and mixed channels: 4 A; High-speed outputs: 0.8 A- Switching voltage
24 VDC -15% / +20%- Variant
Standard outputs and mixed channels: Current-sourcing FET; High-speed outputs: Push-Pull- Nonlinearity
<0.05%- Max. offset drift
0.012%/°C- Max. gain drift
0.023 %/°C- Permissible input signal
Short-term max. ±30 V- Measurement current
1 mA- Linearization method
Internal- Resistance measurement resolution
1 LSB = 0x0005 = 0.49 Ω- Sensor standard
EN 60751- Temperature sensor resolution
1 LSB = 0x0005 = 0.16°C- Resistance measurement range
0.1 to 4000 Ω- Output format
INT or UINT for resistance measurement- Digital converter resolution
13-bit- Common-mode range
±12 V- Crosstalk between channels
<-70 dB- Input filter
Third-order low-pass filter / Cutoff frequency 1 kHz- Conversion procedure
SAR- Output of digital value during overload
Configurable- Input protection
Protection against wiring with supply voltage- Input
±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections- Input type
Differential input- Conversion time
1 channel enabled: 100 µs; 2 channels enabled: 200 µs- Timestamp
1 µs resolution- Measurements per module
Each function up to 2x- Signal form
Square wave pulse- Possible measurements
Period measurement, gate measurement, differential time measurement, edge counter, edge times- Overload characteristics of encoder power supply
Short-circuit proof, overload-proof- Counter frequency
250 kHz- Encoder power supply
Module-internal, max. 300 mA- Input frequency
Max. 100 kHz- Counter size
32-bit- Evaluation
4x- Encoder inputs
24 V, asymmetrical- Additional functions
X2 - High-speed digital inputs:; 2x 250 kHz event counting, 2x AB counter, ABR incremental encoder, direction/frequency, period measurement, gate measurement, differential time measurement, edge counters, edge times- Connection type
1-wire connections- Input resistance
X1 - Standard inputs: 6.8 kΩ; X2 - Standard inputs: 8.9 kΩ; X2 - High-speed inputs: 6.8 kΩ; X3 - Mixed channels: 8.9 kΩ- Nominal voltage
24 VDC- Input current at 24 VDC
X1 - Standard inputs: Typ. 3.5 mA; X2 - Standard inputs: Typ. 2.68 mA; X2 - High-speed inputs: Typ. 3.5 mA; X3 - Mixed channels: Typ. 2.68 mA- Input circuit
Sink- Remanent variables
16 kB FRAM, retention >10 years- Quantity
14 standard inputs, 4 high-speed inputs and 4 mixed channels, configuration as input or output using software- Shortest task class cycle time
2 ms- Typical instruction cycle time
0.0419 µs- Integrated I/O processor
Processes I/O data points in the background- Modular interface slots
1- Permissible contact load
10 A- Nominal output voltage
24 VDC- Fuse
Integrated, cannot be replaced- Parallel connection
Yes- Input current
Max. 1 A- Real-time clock
Retention for at least 300 hours, typ. 1000 hours at 25°C, 1 s resolution, -18 to 28 ppm accuracy at 25°C- Reverse polarity protection
Yes- Redundant operation
Yes- FPU
Yes- Nominal output power
2 W- Cooling
Fanless- Status indicators
CPU function, Ethernet, RS232, PLC power supply, I/O power supply, I/O function per channel- B&R ID code
0xE35B- Input voltage
24 VDC -15% / +20%- Interfaces
1x RS232, 1x Ethernet, 1x USB, 1x X2X Link- System module
Controller- Type of signal lines
Shielded lines must be used for all high-speed digital inputs/outputs, line length: Max. 20 m- Power consumption without interface module and USB
4.3 W- Power consumption for X2X Link power supply
0.8 WProduct condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents X20CP1301 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.