Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

X20CP1301 B&R Electronic Components

B&R X20CP1301 X20 PLC, with integrated I/O, x86-200, 128 MB DDR3 RAM, 16 kB FRAM, 1 GB onboard flash drive, 1 insert slot for X20 interface modules, 1 USB interface, 1 RS232 interface, 1 Ethernet interface 10/100BASE-T, 14 digital inputs, 24 VDC, sink, 4 digital inputs
B&R

Part#:X20CP1301

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

X20 PLC, with integrated I/O, x86-200, 128 MB DDR3 RAM, 16 kB FRAM, 1 GB onboard flash drive, 1 insert slot for X20 interface modules, 1 USB interface, 1 RS232 interface, 1 Ethernet interface 10/100BASE-T, 14 digital inputs, 24 VDC, sink, 4 digital inputs

Check out the X20CP1301 B&R price in the box on the right side or send a quick quote.

Product Details

  • Weight300 g
  • Temperature Operation Vertical mounting orientation
    -25 to 50°C
  • Temperature Operation Horizontal mounting orientation
    -25 to 60°C
  • Max. error Current Offset
    0 to 20 mA = 0.1% (Rev.
  • Max. error Voltage Gain
    0.18% (Rev.
  • Max. error Current Gain
    0 to 20 mA = 0.15% (Rev.
  • Max. error Voltage Offset
    0.04% (Rev.
  • Interface IF2 Transfer Auto-MDI/MDIX
    Yes
  • Interface IF2 Transfer Autonegotiation
    Yes
  • Interface IF2 Transfer Full-duplex
    Yes
  • Interface IF2 Transfer Physical layer
    10BASE-T/100BASE-TX
  • Interface IF2 Transfer Half-duplex
    Yes
  • Application memory Writable data amount Results for 5 years
    21.9 GB/day
  • Processor L1 cache Program code
    16 kB
  • Application memory Writable data amount Guaranteed
    40 TB
  • Processor L1 cache Data code
    16 kB
  • Dimensions Height
    99 mm
  • Dimensions Depth
    75 mm
  • Dimensions Width
    164 mm
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Temperature Transport
    -40 to 85°C
  • Temperature Derating
    See section "Switching frequency derating for high-speed digital outputs".
  • Temperature Storage
    -40 to 85°C
  • Installation elevation above sea level >2000 m
    Reduction of ambient temperature by 0.5°C per 100 m
  • Mounting orientation Horizontal
    Yes
  • Installation elevation above sea level 0 to 2000 m
    No limitation
  • Mounting orientation Vertical
    Yes
  • Switching frequency Inductive load
    See section "Switching inductive loads".
  • Switching frequency Resistive load
    Standard outputs and mixed channels: Max. 500 Hz; High-speed outputs: 50 kHz, max. 200 kHz (see section "Switching frequency derating for high-speed digital outputs")
  • Switching delay 1 → 0
    Standard outputs and mixed channels: <300 µs; High-speed outputs: <3 µs
  • Switching delay 0 → 1
    Standard outputs and mixed channels: <300 µs; High-speed outputs: <3 µs
  • Pulse width modulation Resolution for pulse duration
    0.1% of the configured frequency
  • Temperature sensor normalization Pt1000
    -200 to 850°C
  • Pulse width modulation Pulse duration
    0 to 100%, minimum 2.5 µs
  • Pulse width modulation Period duration
    5 to 65535 µs corresponds to 200 kHz to 15 Hz
  • Max. error at 25°C Offset
    0.15% (Rev.
  • Max. error at 25°C Gain
    0.3% (Rev.
  • Sensor Pt1000
    -200 to 850°C
  • Nonlinearity Voltage
    <0.025%
  • Nonlinearity Current
    <0.05%
  • Common-mode rejection 50 Hz
    70 dB
  • Common-mode rejection DC
    70 dB
  • Max. offset drift Current
    0 to 20 mA = 0.008 %/°C / 4 to 20 mA = 0.012 %/°C
  • Max. offset drift Voltage
    0.008 %/°C
  • Max. gain drift Current
    0 to 20 mA = 0.015 %/°C / 4 to 20 mA = 0.023 %/°C
  • Permissible input signal Current
    Max. ±50 mA
  • Max. gain drift Voltage
    0.017 %/°C
  • Permissible input signal Voltage
    Max. ±30 V
  • Load Voltage
    -
  • Input impedance in signal range Current
    -
  • Load Current
    <300 Ω
  • Input impedance in signal range Voltage
    20 MΩ
  • Output format Current
    INT 0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.883 μA
  • Output format Voltage
    INT 0x8001 - 0x7FFF / 1 LSB = 0x0008 = 2.441 mV
  • Digital converter resolution Current
    12-bit
  • Output format Data type
    INT
  • Digital converter resolution Voltage
    ±12-bit
  • Switching threshold High
    >15 VDC
  • Switching threshold Low
    <5 VDC
  • Input filter Software
    Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments
  • Interface IF4 Max. output current
    0.5 A
  • Input filter Hardware
    Standard inputs and mixed channels: ≤200 μs; High-speed inputs: ≤2 μs, when used as standard inputs: ≤200 μs
  • Interface IF6 Fieldbus
    X2X Link master
  • Interface IF4 Variant
    Type A
  • Interface IF2 Line length
    Max. 100 m between 2 stations (segment length)
  • Interface IF4 Type
    USB 1.1/2.0
  • Interface IF2 Transfer rate
    10/100 Mbit/s
  • Interface IF2 Variant
    1x RJ45 shielded
  • Interface IF2 Signal
    Ethernet
  • Interface IF1 Transfer rate
    Max. 115.2 kbit/s
  • Interface IF1 Max. distance
    900 m
  • Interface IF1 Signal
    RS232
  • Interface IF1 Variant
    Connection via 16-pin terminal block X20TB1F
  • Application memory Error-correcting code (ECC)
    Yes
  • Application memory Guaranteed erase/write cycles
    20,000
  • Application memory Type
    1 GB eMMC flash memory
  • Application memory Data retention
    10 years
  • Standard memory RAM
    128 MB DDR3 SDRAM
  • Processor L2 cache
    128 kB
  • Processor Clock frequency
    200 MHz
  • Certifications ABS
    Yes
  • Certifications EAC
    Yes
  • Processor Type
    Vx86EX
  • Certifications LR
    ENV1
  • Certifications KR
    Yes
  • Certifications DNV
    Temperature: B (0 - 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications UKCA
    Yes
  • Support Visual Components support
    Yes
  • Certifications CE
    Yes
  • Power consumption Internal I/O
    2.3 W
  • Support Controller redundancy
    No
  • Support ACOPOS support
    Yes
  • Support reACTION-capable I/O channels
    No
  • Diagnostics RS232 data transfer
    Yes, using LED status indicator
  • Diagnostics I/O power supply
    Yes, using LED status indicator
  • Diagnostics Temperature
    Yes, using software register
  • Diagnostics Supply voltage monitoring
    Yes, using LED status indicator
  • Diagnostics Ethernet
    Yes, using LED status indicator
  • Diagnostics CPU function
    Yes, using LED status indicator
  • Diagnostics Inputs
    Analog inputs: Yes, using LED status indicator and software
  • Diagnostics Outputs
    Digital outputs: Yes, using LED status indicator and software (output error status)
  • Note
    X20 end cover plate (right) included in delivery; 3 X20 terminal blocks (16-pin) included in delivery; Interface module slot cover included in delivery
  • Electrical isolation
    Ethernet (IF2) and X2X (IF6) isolated from each other, from other interfaces and from PLC; Channel isolated from bus; Channel not isolated from channel or PLC
  • Braking voltage when switching off inductive loads
    Standard outputs and mixed channels: Typ. 45 VDC
  • Switch-on in the event of overload shutdown or short-circuit shutdown
    Standard outputs and mixed channels: Approx. 10 ms (depends on module temperature); High-speed outputs: No switch-on
  • Degree of protection per EN 60529
    IP20
  • Residual voltage
    Standard outputs and mixed channels: <0.1 V at nominal current 0.5 A; High-speed outputs: <0.9 V at nominal current 0.1 A
  • Peak short-circuit current
    Standard outputs and mixed channels: <3 A; High-speed outputs: <20 A
  • Leakage current when the output is switched off
    Standard outputs and mixed channels: 5 µA; High-speed outputs: 25 µA
  • RDS(on)
    140 mΩ
  • Output protection
    Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current"); Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")
  • Diagnostic status
    Standard outputs and mixed channels: Output monitoring with 10 ms delay; High-speed outputs: Output monitoring with 10 µs delay
  • Output circuit
    Standard outputs and mixed channels: Source; High-speed outputs: Sink or source
  • Nominal output current
    Standard outputs and mixed channels: 0.5 A; High-speed outputs: 0.2 A
  • Standardized range of values for resistance measurement
    0.1 to 4000.0 Ω
  • Total nominal current
    Standard outputs and mixed channels: 4 A; High-speed outputs: 0.8 A
  • Switching voltage
    24 VDC -15% / +20%
  • Variant
    Standard outputs and mixed channels: Current-sourcing FET; High-speed outputs: Push-Pull
  • Nonlinearity
    <0.05%
  • Max. offset drift
    0.012%/°C
  • Max. gain drift
    0.023 %/°C
  • Permissible input signal
    Short-term max. ±30 V
  • Measurement current
    1 mA
  • Linearization method
    Internal
  • Resistance measurement resolution
    1 LSB = 0x0005 = 0.49 Ω
  • Sensor standard
    EN 60751
  • Temperature sensor resolution
    1 LSB = 0x0005 = 0.16°C
  • Resistance measurement range
    0.1 to 4000 Ω
  • Output format
    INT or UINT for resistance measurement
  • Digital converter resolution
    13-bit
  • Common-mode range
    ±12 V
  • Crosstalk between channels
    <-70 dB
  • Input filter
    Third-order low-pass filter / Cutoff frequency 1 kHz
  • Conversion procedure
    SAR
  • Output of digital value during overload
    Configurable
  • Input protection
    Protection against wiring with supply voltage
  • Input
    ±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections
  • Input type
    Differential input
  • Conversion time
    1 channel enabled: 100 µs; 2 channels enabled: 200 µs
  • Timestamp
    1 µs resolution
  • Measurements per module
    Each function up to 2x
  • Signal form
    Square wave pulse
  • Possible measurements
    Period measurement, gate measurement, differential time measurement, edge counter, edge times
  • Overload characteristics of encoder power supply
    Short-circuit proof, overload-proof
  • Counter frequency
    250 kHz
  • Encoder power supply
    Module-internal, max. 300 mA
  • Input frequency
    Max. 100 kHz
  • Counter size
    32-bit
  • Evaluation
    4x
  • Encoder inputs
    24 V, asymmetrical
  • Additional functions
    X2 - High-speed digital inputs:; 2x 250 kHz event counting, 2x AB counter, ABR incremental encoder, direction/frequency, period measurement, gate measurement, differential time measurement, edge counters, edge times
  • Connection type
    1-wire connections
  • Input resistance
    X1 - Standard inputs: 6.8 kΩ; X2 - Standard inputs: 8.9 kΩ; X2 - High-speed inputs: 6.8 kΩ; X3 - Mixed channels: 8.9 kΩ
  • Nominal voltage
    24 VDC
  • Input current at 24 VDC
    X1 - Standard inputs: Typ. 3.5 mA; X2 - Standard inputs: Typ. 2.68 mA; X2 - High-speed inputs: Typ. 3.5 mA; X3 - Mixed channels: Typ. 2.68 mA
  • Input circuit
    Sink
  • Remanent variables
    16 kB FRAM, retention >10 years
  • Quantity
    14 standard inputs, 4 high-speed inputs and 4 mixed channels, configuration as input or output using software
  • Shortest task class cycle time
    2 ms
  • Typical instruction cycle time
    0.0419 µs
  • Integrated I/O processor
    Processes I/O data points in the background
  • Modular interface slots
    1
  • Permissible contact load
    10 A
  • Nominal output voltage
    24 VDC
  • Fuse
    Integrated, cannot be replaced
  • Parallel connection
    Yes
  • Input current
    Max. 1 A
  • Real-time clock
    Retention for at least 300 hours, typ. 1000 hours at 25°C, 1 s resolution, -18 to 28 ppm accuracy at 25°C
  • Reverse polarity protection
    Yes
  • Redundant operation
    Yes
  • FPU
    Yes
  • Nominal output power
    2 W
  • Cooling
    Fanless
  • Status indicators
    CPU function, Ethernet, RS232, PLC power supply, I/O power supply, I/O function per channel
  • B&R ID code
    0xE35B
  • Input voltage
    24 VDC -15% / +20%
  • Interfaces
    1x RS232, 1x Ethernet, 1x USB, 1x X2X Link
  • System module
    Controller
  • Type of signal lines
    Shielded lines must be used for all high-speed digital inputs/outputs, line length: Max. 20 m
  • Power consumption without interface module and USB
    4.3 W
  • Power consumption for X2X Link power supply
    0.8 W

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo