1SAZ721201R1033 ABB Control Industrial Automation Components

ABB Control 1SAZ721201R1033 ABB 1SAZ721201R1033 is a thermal overload relay designed for thermal overload protection with a manual/automatic reset function, test trip function, stop function, and a rotary knob for adjusting the rated motor current. It features direct connection to contact for ingoing connections and screw-clamp connections for outgoing connections. The rated current is adjustable between 2.3A and 3.1A. This ATEX variant includes bimetallic tripping elements and has 1NO+1NC auxiliary contacts. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 88.3 mm, a net width of 45 mm, and a net depth of 70.5 mm. The relay is designed for 3-poles (3P) and offers protection functions against 3-phase overload, phase loss, and thermal overload Class 10. It has a rated insulation voltage (Ui) of 690 V, a rated impulse voltage (Uimp) of 6 kV, and can be directly mounted on a contactor. The rated active power is 0.75kW / 750W at 400/415Vac, with a rated operating voltage (Ue) of 690 V (IEC) and 600 V (UL/CSA). It is suitable for networks with a frequency of 50/60 Hz and includes a visual position indicator for trip indication on the front. Power dissipation/losses are between 1.1W and 2 W per pole at rated operating conditions, and the protection settings allow for thermal protection adjustment between 2.3A and 3.1A. The operating rate is 15 cycles/hour, with a minimum current of 2.3 A and a maximum current of 3.1 A.
ABB Control

Part#:1SAZ721201R1033

Manufacturer:ABB Control

Product Lifecycle:Active

Get a quick Quote!

ABB 1SAZ721201R1033 is a thermal overload relay designed for thermal overload protection with a manual/automatic reset function, test trip function, stop function, and a rotary knob for adjusting the rated motor current. It features direct connection to contact for ingoing connections and screw-clamp connections for outgoing connections. The rated current is adjustable between 2.3A and 3.1A. This ATEX variant includes bimetallic tripping elements and has 1NO+1NC auxiliary contacts. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 88.3 mm, a net width of 45 mm, and a net depth of 70.5 mm. The relay is designed for 3-poles (3P) and offers protection functions against 3-phase overload, phase loss, and thermal overload Class 10. It has a rated insulation voltage (Ui) of 690 V, a rated impulse voltage (Uimp) of 6 kV, and can be directly mounted on a contactor. The rated active power is 0.75kW / 750W at 400/415Vac, with a rated operating voltage (Ue) of 690 V (IEC) and 600 V (UL/CSA). It is suitable for networks with a frequency of 50/60 Hz and includes a visual position indicator for trip indication on the front. Power dissipation/losses are between 1.1W and 2 W per pole at rated operating conditions, and the protection settings allow for thermal protection adjustment between 2.3A and 3.1A. The operating rate is 15 cycles/hour, with a minimum current of 2.3 A and a maximum current of 3.1 A.

About the manufacturer: ABB Control is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. ABB's Industrial Automation division offers a variety of solutions designed for process and hybrid industries, including industry-specific integrated automation, electrification, and digital solutions, control technologies, software, and advanced services.

Check out the 1SAZ721201R1033 ABB Control price in the box on the right side or send a quick quote.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1SAZ721201R1033 Description

ABB 1SAZ721201R1033 is a thermal overload relay designed for thermal overload protection with a manual/automatic reset function, test trip function, stop function, and a rotary knob for adjusting the rated motor current. It features direct connection to contact for ingoing connections and screw-clamp connections for outgoing connections. The rated current is adjustable between 2.3A and 3.1A. This ATEX variant includes bimetallic tripping elements and has 1NO+1NC auxiliary contacts. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 88.3 mm, a net width of 45 mm, and a net depth of 70.5 mm. The relay is designed for 3-poles (3P) and offers protection functions against 3-phase overload, phase loss, and thermal overload Class 10. It has a rated insulation voltage (Ui) of 690 V, a rated impulse voltage (Uimp) of 6 kV, and can be directly mounted on a contactor. The rated active power is 0.75kW / 750W at 400/415Vac, with a rated operating voltage (Ue) of 690 V (IEC) and 600 V (UL/CSA). It is suitable for networks with a frequency of 50/60 Hz and includes a visual position indicator for trip indication on the front. Power dissipation/losses are between 1.1W and 2 W per pole at rated operating conditions, and the protection settings allow for thermal protection adjustment between 2.3A and 3.1A. The operating rate is 15 cycles/hour, with a minimum current of 2.3 A and a maximum current of 3.1 A.


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of ABB Control

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

ABB Control Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many ABB Control Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from ABB Control, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

1SAZ721201R1028 Part Image. Manufactured by ABB Control.

1SAZ721201R1028

Verified stock: 0

ABB 1SAZ721201R1028 is a Thermal Overload Relay (TOR) designed for thermal overload protection with a manual/automatic reset function, test trip function, stop function, and a rotary knob for adjusting rated motor current. It features direct connection to contact for ingoing connections and screw-clamp connections for outgoing connections. The rated current is adjustable between 1.3A and 1.7A. This ATEX variant includes bimetallic tripping elements and 1NO+1NC auxiliary contacts. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 88.3 mm, a net width of 45 mm, and a net depth of 70.5 mm. The relay is equipped with 3 poles (3P) and offers protection functions against 3-phase overload, phase loss, and thermal overload Class 10. The rated insulation voltage (Ui) is 690 V, with a rated impulse voltage (Uimp) of 6 kV. It supports direct mounting on contactors and has a rated active power of 0.55kW / 550W at 400/415Vac. The rated operating voltage (Ue) is 690 V according to IEC standards and 600 V according to UL/CSA standards, with a network frequency of 50/60 Hz. A visual position indicator for trip indication is located on the front. Power dissipation/losses at rated operating conditions per pole range from 1.1W to 2 W. The protection settings allow for thermal protection with an adjustable overload range of 1.3A to 1.7A, and the operating rate is 15 cycles/hour, with a minimum current of 1.3 A and a maximum current of 1.7 A.

ABB Control