Filters
Manufacturer
More in this category
part#
description
manufacturer
2908661
The output-loop-powered temperature transmitter transmits up to two sensor signals from RTD and TC sensors as well as from resistance-type sensors and voltage sensors via HART communication or 4 ... 20 mA, configurable. SIL 2/3, intrinsic safety, Push-in
Phoenix Contact
Quick Quote
2700128
LED blinking light element, 24 V AC/DC, clear
Phoenix Contact
Quick Quote
2700127
LED permanent light element, 24 V AC/DC, clear
Phoenix Contact
Quick Quote
2700147
Labeling board for pillars with tube mounting, complete with mounting material
Phoenix Contact
Quick Quote
2700153
Outlet box with lateral cable entry for floor and base mounting
Phoenix Contact
Quick Quote
2800616
Optical lightning sensor for the live monitoring system for the continuous detection and evaluation of lightning strikes. IP67 protection.
Phoenix Contact
Quick Quote
1018874
Siren element, 8 tones, 24 V AC/DC, max. 95 dB, 8 tones selectable by DIP switch, black
Phoenix Contact
Quick Quote
1018853
Base with integrated M12 male (5 pins)
Phoenix Contact
Quick Quote
1018740
Base for horizontal and third-party tube assembly
Phoenix Contact
Quick Quote
1191993
IO-Link device for modular signal towers
Phoenix Contact
Quick Quote
2865599
HART Multiplexer for online configuration and diagnostics of HART-compatible field devices, as well as for continuous documentation of process variables and states with a PC or management system for mounting on NS 35/7.5 or NS 32
Phoenix Contact
Quick Quote
2882572
Surge protection in the IP67 screw-on module for measuring sensors in intrinsically safe circuits, direct mounting with 1/2" NPT outer thread, cable gland for the signal cable, two-stage protective circuit. HART-compatible.
Phoenix Contact
Quick Quote
2906170
Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can be set via DIP switch and potentiometer, galvanic 3-way electrical isolation, up to SIL2 (SC3), PLc Cat.1, Push-in connection.
Phoenix Contact
Quick Quote
2924139
Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Push-in connection.
Phoenix Contact
Quick Quote
2924074
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Phoenix Contact
Quick Quote
2902961
The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor the supply voltages. The error is reported via an N/O contact. Screw connection, standard configuration.
Phoenix Contact
Quick Quote
2908738
Pipe fastening for FA MCR-HT-FH field housing
Phoenix Contact
Quick Quote
2908735
Display unit for plugging directly into the FA MCR-... head transmitter
Phoenix Contact
Quick Quote
1105515
Output loop-powered head transmitter for transmitting up to two sensor signals from RTD and TC sensors as well as from resistance-type sensors and voltage sensors via HART(R) communication or 4 ... 20 mA, freely configurable, SIL2/3, screw connection.
Phoenix Contact
Quick Quote
Items per page: