About the product: 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, standard conf
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902037 Phoenix Contact price in the box on the right side or send a quick quote.
2902037 Product Details
- Height 109.81 mm
- Width 6.2 mm
- Maximum altitude ≤ 2000 m
- Current input signal 0 mA ... 20 mA (via DIP switch)
- Number of outputs 1
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Connection method Screw connection
- Power consumption ≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
- Maximum transmission error ≤ 0.1 % (of final value)
- ETIM 4.0 EC002653
- UNSPSC 6.01 30211502
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Input resistance current input approx. 63 Ω (+0.7 V for test diode)
- Ripple < 20 mVPP (at 600 Ω)
- Nominal supply voltage 24 V DC
- Screw thread M3
- Maximum temperature coefficient 0.01 %/K
- ECLASS 9.0 27210120
- UNSPSC 11 39121004
- UNSPSC 21.0 39121008
- Depth 119.2 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Degree of protection IP20 (not assessed by UL)
- max. input voltage 33 V
- Voltage output signal 0 V ... 5 V (via DIP switch)
- Load/output load voltage output ≥ 10 kΩ
- Short-circuit current < 32 mA
- Stripping length 10 mm
- No. of channels 1
- ETIM 7.0 EC002653
- ETIM 6.0 EC002653
- UNSPSC 19.0 39121008
- Input resistance of voltage input > 1000 kΩ
- Current output signal 0 mA ... 20 mA (via DIP switch)
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Conductor cross section solid 0.2 mm² ... 1.5 mm² (with ferrule)
- ECLASS 6.0 27210100
- Ambient temperature (operation) -40 °C ... 70 °C
- UNSPSC 13.2 39121008
- UNSPSC 20.0 39121008
- Number of inputs 1
- Max. input current 24 mA
- Conductor cross section AWG 24 ... 12 (flexible)
- Torque 0.5 Nm ... 0.6 Nm
- Temperature coefficient, typical 0.01 %/K
- Color gray
- UNSPSC 7.0901 39121004
- UNSPSC 12.01 39121004
- Configurable/programmable Yes
- Voltage input signal 0 V ... 5 V (via DIP switch)
- Max. output current 22 mA
- Typical current consumption 25 mA (Current output, at 24 V DC incl. load)
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Identification UL 508 Listed
- REACh SVHC Lead 7439-92-1
- Noise emission EN 61000-6-4
- ECLASS 11.0 27210120
- ECLASS 4.1 27210100
- Certificate DNV GL TAA00002UA
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 5.0 27210100
- ECLASS 7.0 27210120
- Mounting position any
- Temperature B
- EMC A
- ECLASS 10.0.1 27210120
- Standards/regulations EN 61000-4-6
- Humidity B
- Vibration A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27210100
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Overvoltage category II
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- Housing material PBT
- Designation Shipbuilding approval
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Electromagnetic compatibility Conformance with EMC directive
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Protective circuit Transient protection
- Step response (10-90%) < 8.5 ms (with 30 Hz filter)
- Limit frequency (3 dB) 30 Hz (via DIP switch)
- Degree of pollution 2
- Rated insulation voltage 300 V (effective)
- ECLASS 5.1 27210100
- UNSPSC 18.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
This item can ship within 24h!
1-year warranty
$264.15
2902037
Stock:
348
Select Qty:
$264.15
$264.15 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨