Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3211427 Phoenix Contact Terminal Blocks

Phoenix Contact 3211427 Component terminal block, with integrated 1N4007 diode, The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A., nom. voltage: 500 V, nominal current: 0.5 A, connection method: Pus
Phoenix Contact

Part#:3211427

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 10

Nov 30, 2024

Component terminal block, with integrated 1N4007 diode, The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A., nom. voltage: 500 V, nominal current: 0.5 A, connection method: Pus

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3211427 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Result of tight fit on support
    Test passed
  • Height NS 35/15
    55 mm
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • Stripping length
    8 mm ... 10 mm
  • Connection in acc. with standard
    CSA
  • ECLASS 7.0
    27141120
  • ETIM 7.0
    EC000903
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • Note
    The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A.
  • Color
    gray
  • Rated surge voltage
    6 kV
  • Insulating material group
    I
  • Maximum load current
    0.5 A
  • Maximum power dissipation for nominal condition
    0.77 W (the value is multiplied when connecting multiple levels)
  • Back of the hand protection
    guaranteed
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Checking the mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Number of levels
    2
  • Nominal cross section
    2.5 mm²
  • Degree of pollution
    3
  • Nominal current IN
    0.5 A
  • Open side panel
    Yes
  • Result of surge voltage test
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test turns
    135
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Tight fit on carrier
    NS 35
  • Result of temperature-rise test
    Test failed
  • Short-time current
    0.48 kA
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Shock test result
    Test passed
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock form
    Half-sine
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    5.2 mm
  • Number of connections
    4
  • Insulating material
    PA
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Nominal voltage UN
    500 V
  • Finger protection
    guaranteed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Surge voltage test setpoint
    7.3 kV
  • Bending test rotation speed
    10 rpm
  • Conductor cross section tensile test
    4 mm²
  • Tractive force setpoint
    60 N
  • Short circuit stability result
    Test passed
  • Setpoint
    1 N
  • Result of thermal test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Acceleration
    5g
  • Test duration per axis
    5 h
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Number of shocks per direction
    3
  • Relative insulation material temperature index (Elec.; UL 746 B)
    130 °C
  • Conductor cross section AWG max.
    12
  • Height NS 35/7,5
    47.5 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • Internal cylindrical gage
    A3
  • ECLASS 4.0
    27141100
  • ECLASS 5.0
    27141100
  • ECLASS 9.0
    27141127
  • UNSPSC 12.01
    39121410
  • UNSPSC 19.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section AWG min.
    26
  • ECLASS 10.0.1
    27141127
  • ECLASS 4.1
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC000897
  • UNSPSC 18.0
    39121410
  • Result of aging test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • ASD level
    1.857 (m/s2)2/Hz
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Conductor cross section solid min.
    0.14 mm²
  • Result of voltage-drop test
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • ETIM 2.0
    EC000897
  • UNSPSC 21.0
    39121410
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000897
  • Conductor cross section short circuit testing
    4 mm²
  • Shock duration
    30 ms
  • Static insulating material application in cold
    -60 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Length
    68 mm
  • Connection method
    Push-in connection
  • Conductor cross section solid max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ETIM 6.0
    EC000903
  • UNSPSC 11
    39121410
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    0.5 mm²
  • ECLASS 11.0
    27141127
  • UNSPSC 6.01
    30211811
  • UNSPSC 13.2
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$11.59

Stock:

10

Select Qty:

$11.59

$11.59 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo