3210266 Phoenix Contact Terminal Blocks

Phoenix Contact 3210266 Component terminal block, with integrated 1N4007 diode, The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A., nom. voltage: 800 V, nominal current: 0.5 A, connection method: Pus
Phoenix Contact

Part#:3210266

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 85

Nov 23, 2024

Component terminal block, with integrated 1N4007 diode, The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A., nom. voltage: 800 V, nominal current: 0.5 A, connection method: Pus

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3210266 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Color
    gray
  • Overvoltage category
    III
  • Maximum load current
    0.5 A (with 4 mm² conductor cross section, rigid)
  • Finger protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Result of tight fit on support
    Test passed
  • Short-time current
    0.48 kA
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Number of shocks per direction
    3
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section solid max.
    4 mm²
  • Nominal cross section
    2.5 mm²
  • Rated surge voltage
    8 kV
  • Maximum power dissipation for nominal condition
    0.77 W
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Tensile test result
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short circuit stability result
    Test passed
  • Result of aging test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • ASD level
    1.857 (m/s2)2/Hz
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/7,5
    36.5 mm
  • Connection
    1 level
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section AWG max.
    12
  • Min. AWG conductor cross section, flexible
    26
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • ETIM 2.0
    EC000897
  • ETIM 7.0
    EC000903
  • UNSPSC 13.2
    39121410
  • UNSPSC 19.0
    39121410
  • UNSPSC 20.0
    39121410
  • Number of connections
    4
  • Insulating material group
    I
  • Open side panel
    Yes
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tight fit on carrier
    NS 35
  • Result of thermal test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Shock test result
    Test passed
  • Shock duration
    30 ms
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Height NS 35/15
    44 mm
  • Connection method
    Push-in connection
  • Conductor cross section flexible min.
    0.14 mm²
  • Max. AWG conductor cross section, flexible
    14
  • Connection cross sections directly pluggable
    0.34 mm² 4 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27141100
  • ETIM 3.0
    EC000897
  • ETIM 6.0
    EC000903
  • UNSPSC 11
    39121410
  • UNSPSC 18.0
    39121410
  • Number of levels
    1
  • Insulating material
    PA
  • Degree of pollution
    3
  • Nominal voltage UN
    800 V
  • Result of surge voltage test
    Test passed
  • Power frequency withstand voltage setpoint
    2 kV
  • Bending test rotation speed
    10 rpm
  • Setpoint
    1 N
  • Result of voltage-drop test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Acceleration
    5g
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Width
    5.2 mm
  • Length
    72 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    0.5 mm²
  • Internal cylindrical gage
    A3
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 10.0.1
    27141127
  • ECLASS 6.0
    27141100
  • ECLASS 7.0
    27141127
  • UNSPSC 6.01
    30211811
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410
  • Note
    Measured with diode.
  • Potentials
    1
  • Flammability rating according to UL 94
    V0
  • Nominal current IN
    0.5 A
  • Back of the hand protection
    guaranteed
  • Bending test turns
    135
  • Conductor cross section short circuit testing
    4 mm²
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test duration per axis
    5 h
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Connection in acc. with standard
    CSA
  • ECLASS 11.0
    27141127
  • ECLASS 4.0
    27141100
  • ECLASS 5.1
    27141100
  • ECLASS 9.0
    27141127
  • ETIM 4.0
    EC000897
  • UNSPSC 12.01
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$9.16

Stock:

85

Select Qty:

$9.16

$9.16 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo