3210059 Phoenix Contact Terminal Blocks
Part#:3210059
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 23
Nov 29, 2024
Ground modular terminal block, connection method: Push-in / plug connection, number of connections: 2, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3210059 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Acceleration 5g
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 35/15 44 mm
- Connection 1 level
- Conductor cross section AWG min. 26
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 10.0.1 27141141
- ECLASS 5.0 27141100
- Overvoltage category III
- Oscillation, broadband noise test result Test passed
- Shock duration 30 ms
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 48.5 mm
- Connection method Push-in / plug connection
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- Number of levels 1
- Insulating material PA
- Degree of pollution 3
- Maximum load current with 4 mm² conductor cross section, rigid
- Shock test result Test passed
- Number of shocks per direction 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/7,5 36.5 mm
- Connection in acc. with standard CSA
- Conductor cross section AWG max. 12
- Min. AWG conductor cross section, flexible 26
- Connection cross sections directly pluggable 0.34 mm² 4 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.0 27141100
- ECLASS 6.0 27141100
- ETIM 7.0 EC000901
- UNSPSC 13.2 39121410
- Nominal cross section 2.5 mm²
- Rated surge voltage 6 kV
- Maximum power dissipation for nominal condition 0.77 W
- Test spectrum Service life test category 1, class B, body mounted
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Width 5.2 mm
- End cover width 2.2 mm
- Stripping length 8 mm ... 10 mm
- Conductor cross section solid max. 4 mm²
- Conductor cross section flexible max. 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Internal cylindrical gage A3
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 11.0 27141141
- ETIM 2.0 EC000901
- UNSPSC 6.01 30211811
- UNSPSC 18.0 39121410
- Color green-yellow
- Area of application Railway industry
- Insulating material group I
- ASD level 0.964 (m/s2)2/Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock form Half-sine
- Surface flammability NFPA 130 (ASTM E 162) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Height 35.3 mm
- Note Please observe the current carrying capacity of the DIN rails.
- Conductor cross section solid min. 0.34 mm²
- Max. AWG conductor cross section, flexible 14
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 0.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.1 27141100
- ETIM 4.0 EC000901
- ECLASS 9.0 27141141
- UNSPSC 7.0901 39121410
- UNSPSC 19.0 39121410
- UNSPSC 20.0 39121410
- UNSPSC 21.0 39121410
- Number of connections 2
- ETIM 3.0 EC000901
- ETIM 6.0 EC000901
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Ambient temperature (actuation) -5 °C ... 70 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- ECLASS 5.1 27141100
- UNSPSC 12.01 39121410
- Open side panel Yes
- Flammability rating according to UL 94 V0
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test duration per axis 5 h
- ECLASS 7.0 27141141
- UNSPSC 11 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$5.71
Stock:
23
Select Qty:
$5.71
$5.71 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨