Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2910326 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2910326 Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300 mm, diameter: 95 mm. Length of signal line: 10 m. The Rogowski coil measures the AC current of busbars and power lines.
Phoenix Contact

Part#:2910326

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300 mm, diameter: 95 mm. Length of signal line: 10 m. The Rogowski coil measures the AC current of busbars and power lines.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2910326 Phoenix Contact price in the box on the right side or send a quick quote.

2910326 Product Details

  • Width
    22.5 mm
  • Measuring transducer degree of protection
    IP20
  • Configurable/programmable
    Via DIP switches
  • Input signal (at 50 Hz)
    100 mV (1000 A)
  • Conductor structure signal line
    2x 0.22 mm (Signal (tinned))
  • Diameter of measuring coil
    8.3 mm ±0.2 mm
  • Rated insulation voltage
    1000 V AC (rms CAT III)
  • Standards/regulations
    IEC 61010-1
  • Connection method
    Screw connection
  • Maximum altitude
    < 2000 m
  • Depth
    70.4 mm
  • Nominal supply voltage range
    19.2 V DC ... 30 V DC
  • Power consumption
    4 W
  • Frequency measuring range
    40 Hz ... 20000 Hz
  • Max. distances for copper cables at PN max
    32 m (0.75 mm² (AWG 20))
  • Output signal (at 50 Hz)
    100 mV (no load, at 1,000 A)
  • Load
    0 Ω ... 1.5 Ω
  • Coil material
    Elastollan
  • Basic accuracy
    <± 0.2 %
  • Typical measuring error
    < 1 %
  • Stripping length
    7 mm
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27210900
  • Height
    85 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Max. current consumption
    190 mA
  • Linearity error
    < 0.5 % (From the range end value)
  • Phase angle
    < 1 °
  • Output voltage (in no-load operation)
    VOUT = M * dI/dt
  • Current output signal
    0 A AC ... 1 A
  • Insulation
    double insulation
  • Current consumption
    < 190 mA (at 19.2 V)
  • Conductor cross section AWG
    24 ... 14
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • ECLASS 5.1
    27210900
  • ETIM 7.0
    EC002048
  • Ambient temperature (operation)
    -30 °C ... 80 °C (Measuring coil)
  • Measuring coil degree of protection
    IP67 (not assessed by UL)
  • Position error
    <± 1 % (typical)
  • Measuring ranges (current)
    100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
  • Length of measuring coil
    300 mm
  • Output voltage (sinusoidal, in no-load operation)
    100 mV (VOUT = 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))
  • Housing material
    Polyamide
  • UL, USA/Canada
    UL 508 Listed
  • Maximum transmission error
    ≤ 0.5 % (From the range end value)
  • Frequency range
    45 Hz ... 65 Hz
  • Temperature coefficients
    0.005 %/K (+10 °C ... +70 °C, both components have the same ambient temperature)
  • Screw thread
    M3
  • Pollution degree
    2
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27210900
  • ECLASS 9.0
    27210902
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C (Measuring coil)
  • Nominal supply voltage
    24 V DC -20 % ... +25 %
  • Rated power
    1.5 VA
  • Input impedance
    27 kΩ (smallest measuring range)
  • Length of signal cable
    10000 mm
  • Test voltage
    1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
  • Max. detectable harmonics
    < 2 kHz
  • Connection name
    Measuring transducer side
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Overvoltage category
    III (1000 V, to neutral conductor)
  • ECLASS 11.0
    27210902
  • ECLASS 7.0
    27210902
  • Torque
    0.5 Nm ... 0.6 Nm
  • ECLASS 10.0.1
    27210902
  • ECLASS 4.0
    27210900
  • ECLASS 5.0
    27210900
  • ETIM 6.0
    EC002048

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2910326

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo