Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2910120 Phoenix Contact DC/DC Converters

Phoenix Contact 2910120 Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 24 V DC / 10 A
Phoenix Contact

Part#:2910120

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 24 V DC / 10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2910120 Phoenix Contact price in the box on the right side or send a quick quote.

2910120 Product Details

  • ECLASS 10.0.1
    27210901
  • Electric strength, max.
    35 V DC (60 s)
  • Inrush current limitation typical
    1.5 A (after 1 ms)
  • Type test (IEC/EN 60950-1) D
    0.5 kV DC
  • Production test D
    0.5 kV DC
  • Static Boost (IStat.Boost)
    12.5 A
  • Conductor cross section AWG
    24 ... 16
  • Typical current consumption
    13.8 A (24 V DC)
  • Type test (IEC/EN 60950-1) B
    4 kV DC
  • Stripping length
    8 mm
  • System deviation, input voltage change
    < 0.1 % (change in input voltage ±10 %)
  • Feedback voltage resistance
    ≤ 35 V DC
  • UOut
    > 0.9 x USet (LED lights up green)
  • Default
    Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
  • Switch contact
    floating
  • Main converter stage
    67 kHz ... 135 kHz (Main converter stage)
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Width with alternative assembly
    122 mm
  • Depth with alternative assembly
    53 mm
  • Vibration (operation)
    5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
  • Overvoltage category EN 61010-1
    II
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    50 Hz ... 60 Hz
  • Comments
    Criterion A
  • Input
    1 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • Voltage dips
    EN 61000-4-29
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Attenuated oscillating wave
    EN 61000-4-18
  • Criterion A
    Normal operating behavior within the specified limits.
  • Input voltage range
    18 V DC ... 32 V DC
  • Typical response time
    300 ms (from SLEEP MODE)
  • Insulation voltage input/output
    4 kV DC (type test)
  • Type test (IEC/EN 60950-1) C
    0.5 kV DC
  • Production test B
    2 kV DC
  • Conductor cross section solid
    0.2 mm² ... 1 mm²
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
  • Selective Fuse Breaking (ISFB)
    60 A (15 ms)
  • Residual ripple
    < 50 mVPP
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Connection labeling
    3.4 +
  • Reference potential
    to OUT1, OUT2, REM
  • MTBF (IEC 61709, SN 29500)
    > 1380000 h (25 °C)
  • Hood version
    Stainless steel X6Cr17
  • Depth
    125 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Degree of pollution
    2
  • EMC requirements for noise emission
    EN 61000-6-3
  • Overvoltage category EN 62477-1
    III
  • Identification
    ABS
  • Conducted noise emission
    EN 55016
  • Switch-on time
    < 1 s
  • Type test (IEC/EN 60950-1) A
    2 kV DC
  • Production test A
    2 kV DC
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.2 mm² ... 0.75 mm²
  • Nominal output voltage (UN)
    24 V DC
  • Dynamic Boost (IDyn.Boost)
    20 A (5 s)
  • System deviation, static
    < 1 % (change in load, static 10 % ... 90 %)
  • No-load proof
    yes
  • Rise time
    < 1 s (UOUT (10 % ... 90 %))
  • POut
    > 100 % (LED lights up yellow, output power > 240 W)
  • Signal option
    Output current
  • Maximum contact load
    24 V DC
  • Temperature
    30 °C
  • Side element version
    Aluminum
  • Protection class
    Special with SELV input and output
  • Weight
    0.8 kg
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • EMC requirements, power plant
    IEC 61850-3
  • Designation
    Shipbuilding
  • Noise emission
    EN 55016
  • DNV GL noise radiation
    Class B
  • Discharge in air
    15 kV (Test Level 4)
  • Electromagnetic HF field
    EN 61000-4-3
  • Surge voltage load (surge)
    EN 61000-4-5
  • Frequency
    0 Hz
  • Voltage dip
    0 %
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • Alternating component of DC voltage
    EN 61000-4-17
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 9.0
    27210901
  • Mains buffering
    typ. 11 ms (24 V DC)
  • Inrush current integral (I2t)
    < 0.02 A2s
  • Input fuse
    30 A (slow-blow, internal)
  • Production test C
    0.5 kV DC
  • Connection method
    Push-in connection
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Nominal output current (IN)
    10 A
  • Magnetic circuit breaker tripping
    A1...A6 / B2...B6 / C1...C3 / Z1...Z6
  • Short-circuit-proof
    yes
  • Connection in series
    yes
  • Types of signaling
    LED
  • Analog
    4 mA ... 20 mA ±5 % (Load ≤400 Ω)
  • Output current
    10 A
  • Voltage
    1 kV
  • Auxiliary converter stage
    190 kHz ... 220 kHz (Auxiliary converter stage)
  • Height
    130 mm
  • Efficiency
    typ. 93.3 % (24 V DC)
  • Maximum power dissipation in no-load condition
    < 5 W
  • Power dissipation SLEEP MODE
    < 2 W
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Climatic class
    3K3 (EN 60721)
  • Standard designation
    Mains variation/undervoltage
  • Standards/regulations
    EN 61000-4-29
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • DNV GL conducted interference
    Class B
  • Additional text
    Test Level 2
  • Fast transients (burst)
    EN 61000-4-4
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ETIM 7.0
    EC002046
  • System deviation, dynamic
    < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • UIn
    > 0.8 x UInNom (LED off)
  • Digital
    0 V DC
  • Function
    Signal ground
  • Time
    422400 h
  • Degree of protection
    IP20
  • Width
    50 mm
  • Height with alternative assembly
    130 mm
  • Power loss nominal load max.
    < 16 W
  • Maximum altitude
    ≤ 5000 mm (> 2000 m, observe derating)
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • Test level 6
    0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
  • Input, output (test level 3)
    10 MHz (Test Level 2 - asymmetrical)
  • ECLASS 11.0
    27210901
  • Contact discharge
    8 kV (Test Level 4)
  • Test field strength
    100 A/m
  • Signal
    2 kV (Test Level 3 - asymmetrical)
  • Power frequency magnetic field
    EN 61000-4-8
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Input, output (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • ETIM 6.0
    EC002046

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2910120

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo