Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2909577 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2909577 Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 3.8 A
Phoenix Contact

Part#:2909577

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 127

Apr 24, 2024

About the product: Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 3.8 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2909577 Phoenix Contact price in the box on the right side or send a quick quote.

2909577 Product Details

  • Installation distance top/bottom
    30 mm / 30 mm
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Inrush current
    typ. 13 A (at 25 °C)
  • Input fuse
    3.15 A (slow-blow, internal)
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (constant capacity)
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Residual ripple
    < 45 mVPP (with nominal values)
  • Net weight
    0.296 kg
  • Width
    45 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Mains buffering time
    typ. 35 ms (120 V AC)
  • Type of protection
    Transient surge protection
  • Derating
    > 60 °C (2.5%/K)
  • Control deviation
    < 0.5 % (Static load change 10 % ... 90 %)
  • Output power
    90 W
  • Environmental protection directive
    RoHS Directive 2011/65/EU
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    14
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Discharge in air
    8 kV (Test Level 3)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Power frequency magnetic field
    EN 61000-4-8
  • Additional text
    Test Level 2
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • Attenuated oscillating wave
    EN 61000-4-18
  • ECLASS 11.0
    27040701
  • ETIM 7.0
    EC002540
  • UNSPSC 21.0
    39121004
  • Depth
    90 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Degree of pollution
    2
  • Current consumption
    1 A (100 V AC)
  • Nominal power consumption
    104 VA
  • Nominal output voltage
    24 V DC
  • Dynamic Boost (IDyn.Boost)
    7 A (≤ 60 °C (5 s))
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Feedback voltage resistance
    ≤ 35 V DC
  • Maximum power dissipation in no-load condition
    < 1 W (120 V AC)
  • Efficiency
    typ. 92.8 % (120 V AC)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section flexible max.
    2.5 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - Safety of transformers
    EN 61558-2-16
  • UL approvals
    UL Listed UL 61010-1
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Noise emission
    EN 55016
  • Fast transients (burst)
    EN 61000-4-4
  • Input
    2 kV (symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 3)
  • ECLASS 10.0.1
    27040701
  • ECLASS 9.0
    27040701
  • UNSPSC 20.0
    39121004
  • Height
    106 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Dielectric strength maximum
    300 V AC 30 s
  • Protective circuit/component
    Varistor
  • Nominal output current (IN)
    3.8 A
  • Power loss nominal load max.
    < 7 W (120 V AC)
  • Protection class
    II
  • Conductor cross section AWG min.
    24
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Conducted noise emission
    EN 55016
  • Electrostatic discharge
    EN 61000-4-2
  • Comments
    Criterion B
  • I/O/S
    asymmetrical
  • Voltage dip
    0 %
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 6.0
    EC002540
  • UNSPSC 13.2
    39121004
  • Degree of protection
    IP20
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C, D, K or comparable)
  • Connection in series
    yes
  • Typical response time
    500 ms
  • MTBF (IEC 61709, SN 29500)
    > 1272000 h (25 °C)
  • Conductor cross section solid max.
    2.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Safe isolation
    IEC 61558-2-16
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    50 Hz ... 60 Hz
  • Signal
    0.5 kV (Test Level 2 - symmetrical)
  • Frequency
    60 Hz
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Criterion A
    Normal operating behavior within the specified limits.
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.1
    27242213
  • ECLASS 7.0
    27049002
  • UNSPSC 19.0
    39121004
  • Assembly instructions
    DIN rail mounting
  • Conductor cross section solid min.
    0.2 mm²
  • Stripping length
    10 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - power supply devices for low voltage with DC output
    EN 61204-3
  • Contact discharge
    8 kV (Test Level 4)
  • Test field strength
    1000 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Voltage
    300 V (1 s)
  • Voltage dips
    EN 61000-4-11
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 6.0
    27049000
  • UNSPSC 18.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$156.45

2909577

Stock:

127

Select Qty:

$156.45

$156.45 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo