Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2908670 Phoenix Contact Data & Networking Devices

Phoenix Contact 2908670 Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
Phoenix Contact

Part#:2908670

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Data & Networking Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2908670 Phoenix Contact price in the box on the right side or send a quick quote.

2908670 Product Details

  • Rated operating current Ie
    9 A (AC-51)
  • Leakage current
    0 mA
  • Mounting type
    DIN rail mounting
  • Status display
    Yellow LED
  • Stripping length
    10 mm
  • ETIM 2.0
    EC001037
  • ECLASS 5.1
    27024000
  • UNSPSC 6.01
    30211915
  • Cooling time
    20 min. (for auto reset)
  • Motor starter type
    Reversing starter
  • Assembly instructions
    alignable, for spacing see derating
  • Height
    127 mm
  • Overvoltage category
    III
  • ECLASS 7.0
    27024002
  • ECLASS 9.0
    27370905
  • ETIM 6.0
    EC001037
  • UNSPSC 13.2
    25173902
  • UNSPSC 21.0
    25173902
  • Degree of protection
    IP20
  • Rated operating voltage Ue
    500 V AC
  • UNSPSC 18.0
    25173902
  • Note
    If this device is to be used in combination with the CrossPowerSystem power distribution board, the device mount for the 16 A fuse (order designation: EM-CPS-DA-22,5F/16A; order number: 1002668) is required in order to attach the hybrid motor starter to t
  • Maximum altitude
    ≤ 2000 m
  • Type of protection
    Surge protection
  • Output name
    AC output
  • Degree of pollution
    2
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • ECLASS 4.1
    27021100
  • ETIM 3.0
    EC001037
  • ETIM 4.0
    EC001037
  • UNSPSC 11
    39121514
  • UNSPSC 20.0
    25173902
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • Response time
    < 0.5 s
  • Maximum power dissipation
    7 W
  • Group installation
    20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
  • Rated control supply current IS
    65 mA
  • Rated actuating current IC
    7 mA
  • ECLASS 5.0
    27024000
  • ECLASS 6.0
    27024000
  • UNSPSC 7.0901
    39121514
  • ETIM 7.0
    EC001037
  • UNSPSC 19.0
    25173902
  • Operating voltage range
    42 V AC ... 550 V AC
  • Mains frequency
    50/60 Hz
  • Operate threshold
    > 60 A
  • FLA
    7.6 A (480 V AC)
  • Horsepower ratings
    2 hp (208 V AC)
  • UNSPSC 12.01
    39121514
  • Type of note
    Notes on operation
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Typical turn-off time
    < 30 ms
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Depth
    114 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Input name
    Enable input
  • Ambient temperature (operation)
    -5 °C ... 55 °C (observe derating)
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Width
    22.5 mm
  • Rated actuating voltage UC
    24 V DC
  • Switching threshold
    9.6 V (“0” signal)
  • Minimum power dissipation
    0.88 W
  • Connection name
    Load circuit
  • Rated surge voltage
    6 kV
  • ECLASS 10.0.1
    27370905
  • Designation
    Category (ISO 13849)
  • Certificate
    NLDX.E228652
  • Additional text
    Safe shutdown
  • REACh SVHC
    Lead 7439-92-1
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Indication
    Red LED
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 14
  • Standards/regulations
    IEC 60947-1
  • Category code
    NLDX / NRNT
  • ECLASS 11.0
    27370905
  • Load current range
    1.5 A ... 9 A (see to derating)
  • Operating mode
    100% operating factor
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Rated insulation voltage
    550 V
  • Identification
    ≤ 3
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Operating voltage display
    Green LED
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • SCCR
    100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • ECLASS 4.0
    27021100

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2908670

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo