2907916 Phoenix Contact Data & Networking Devices

Phoenix Contact 2907916 Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage: 24 V AC/DC
Phoenix Contact

Part#:2907916

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 599

04/18/2024

About the product: Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage: 24 V AC/DC

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Data & Networking Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2907916 Phoenix Contact price in the box on the right side or send a quick quote.

2907916 Product Details

  • Width
    17.7 mm
  • Permissible humidity (operation)
    5 % ... 95 %
  • Altitude
    ≤ 2000 m (operating voltage remote contact ≤ 250 V)
  • Number of ports
    One
  • Flammability rating according to UL 94
    V-0
  • Housing material
    PA 6.6-FR 20 % GF
  • Nominal voltage UN
    24 V AC (TN-S)
  • Residual current IPE
    ≤ 5 µA
  • Combination wave UOC
    2 kV
  • Height
    93.4 mm
  • Degree of protection
    IP20
  • Ambient temperature (operation)
    -40 °C ... 80 °C
  • Color
    light grey RAL 7035
  • Degree of pollution
    2
  • Maximum continuous voltage UC
    44 V DC
  • Voltage protection level Up (L-PE)
    0.6 kV (at 3 kA)
  • Response time tA (L-PE)
    ≤ 100 ns
  • Connection method
    Screw connection
  • Tightening torque
    4.4 lbf-in.
  • Measured limiting voltage MLV (L-N)
    200 V
  • Vibration (operation)
    5g (5 ... 500 Hz / 2.5 h / X, Y, Z)
  • Mode of protection
    L-N
  • Number of positions
    2
  • Rated load current IL
    20 A
  • Response time tA (L-N)
    ≤ 25 ns
  • Short-circuit current rating ISCCR
    0.25 kA DC (Without additional backup fuse in the DC branch wiring)
  • Switching function
    Changeover contact
  • Conductor cross section AWG
    16 ... 12
  • Maximum continuous operating voltage MCOV
    34 V AC
  • Power distribution system
    Single phase
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 7.0
    27130806
  • Horizontal pitch
    1 Div.
  • EN type
    T3
  • Mounting type
    DIN rail: 35 mm
  • Type
    DIN rail module, two-section, divisible
  • Reference test voltage UREF
    27 V AC
  • Voltage protection level Up (L-N)
    0.25 kV (at 3 kA)
  • TOV behavior at UT (L-PE)
    50 V AC (120 min / withstand mode)
  • Response time tA (N-PE)
    ≤ 100 ns
  • Residual voltage Ures (L-N)
    ≤ 0.16 kV (at 0.5 kA)
  • Operating voltage
    250 V AC (0.5 A)
  • Operating current
    0.5 A AC
  • SPD Type
    4CA
  • Nominal frequency
    50/60 Hz
  • Standards/specifications
    IEC 61643-11 2011
  • ECLASS 11.0
    27130806
  • Depth
    74.5 mm (incl. DIN rail 7.5 mm)
  • Nominal voltage
    34 V DC
  • Shock (operation)
    30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
  • Nominal frequency fN
    50 Hz (60 Hz)
  • TOV behavior at UT (L-N)
    50 V AC (120 min / withstand mode)
  • Max. backup fuse with branch wiring
    32 A (gG / B / C)
  • Residual voltage Ures (N-PE)
    ≤ 0.35 kV (at 0.5 kA)
  • Screw thread
    M3
  • Stripping length
    10 mm
  • Measured limiting voltage MLV (N-G)
    510 V
  • ECLASS 10.0.1
    27130806
  • ETIM 7.0
    EC000942
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • IEC power supply system
    TN-S
  • Surge protection fault message
    Optical, remote indicator contact
  • Nominal discharge current In (8/20) µs
    3 kA
  • Standby power consumption PC
    ≤ 2.7 mVA (at UREF)
  • Voltage protection level Up (N-PE)
    0.6 kV (at 3 kA)
  • Maximum backup fuse for through wiring
    25 A (gG / B / C)
  • Maximum discharge current Imax (8/20) µs
    4 kA
  • Residual voltage Ures (L-PE)
    ≤ 0.35 kV (at 0.5 kA)
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • Nominal discharge current In
    1 kA
  • ETIM 6.0
    EC000942
  • Measured limiting voltage MLV (L-G)
    510 V
  • ECLASS 6.0
    27130800
  • ECLASS 9.0
    27130806

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$184.00

2907916

Stock:

599

Select Qty:

$184.00

$184.00 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo