2907216 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2907216 Multifunctional Ex i process indicator inside the control panel housing for monitoring and displaying analog measurement data. Universal inputs permit connection of current, voltage, RTDs, and TCs. Two relay change-over contact outputs and one analog outp
Phoenix Contact

Part#:2907216

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Multifunctional Ex i process indicator inside the control panel housing for monitoring and displaying analog measurement data. Universal inputs permit connection of current, voltage, RTDs, and TCs. Two relay change-over contact outputs and one analog outp

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2907216 Phoenix Contact price in the box on the right side or send a quick quote.

2907216 Product Details

  • Max. input current
    < 150 mA
  • Transmitter supply voltage
    > 14 V (22 mA)
  • Input resistance of voltage input
    > 1 MΩ
  • Sensor types that can be used (TC)
    J, K, T, N, B, S, R, U. L, C, D
  • D/A converter resolution
    13 bit
  • Minimum switching voltage
    12 V
  • Power consumption
    ≤ 6.9 W
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP65 (Front)
  • Stripping length
    10 mm
  • Test voltage
    2500 V (Relay/relay)
  • Housing material
    PC-GF10
  • ATEX
     II (1) G [Ex ia Ga] IIC
  • GL
    EMC1 C
  • Group
    Ex ia IIC
  • Width
    96 mm
  • Maximum altitude
    < 2000 m (Above sea level)
  • Description of the input
    Universal input
  • Transmitter supply current
    < 30 mA (Short-circuit and overload protection)
  • Voltage input signal
    0 V ... 10 V
  • Number of outputs
    1
  • Load/output load current output
    ≤ 500 Ω (22 mA)
  • Maximum switching voltage
    28 V
  • Max. switching current
    3 A
  • Conductor cross section flexible
    0.14 mm² ... 1.5 mm²
  • Conformance
    CE-compliant
  • ECLASS 4.1
    27210300
  • ECLASS 5.1
    27210300
  • ETIM 3.0
    EC001426
  • UNSPSC 20.0
    39121008
  • Ambient temperature (operation)
    -20 °C ... 60 °C
  • Permissible humidity (operation)
    Front: condensation permitted
  • Current input signal
    0 mA ... 20 mA +10 %
  • Available input sources
    Thermocouples
  • Transmitter supply voltage range
    22.8 V ... 27.6 V (No-load)
  • Max. output current
    < 22 mA
  • Contact type
    Transistor
  • Supply voltage range
    24 V AC/DC ... 230 V AC/DC (-20 % ... +10 %, 50 Hz ... 60 Hz)
  • Conductor cross section AWG
    26 ... 16
  • Test voltage input/power supply
    2500 V
  • UL, USA/Canada
    UL 61010 Recognized
  • ECLASS 11.0
    27210301
  • ETIM 2.0
    EC001426
  • UNSPSC 19.0
    39121008
  • Depth
    175 mm
  • Number of inputs
    1
  • Input resistance current input
    10 Ω
  • Sensor types (RTD) that can be used
    Pt, Ni, Cu sensors
  • max. input voltage
    ± 35 V (≥ 1 V)
  • Configurable/programmable
    Yes
  • Ripple
    < 10 mVPP (1000 Ω)
  • Min. switching current
    10 mA
  • Output description
    Open collector output
  • Connection name
    Input, Output, Status
  • Conductor cross section solid
    0.14 mm² ... 1.5 mm²
  • Test voltage output/power supply
    2500 V
  • Noise emission
    IEC 61326, class A
  • FM approval
    AIS, NI/I/2/ABCDEFG/T4
  • Height
    48 mm
  • Noise immunity
    IEC 61326 / NAMUR NE 21
  • Input signal
    Voltage
  • Connection technology
    2-, 3-, 4-conductor
  • Output name
    Transistor output, active
  • Current output signal
    0 mA ... 20 mA
  • Voltage output signal
    0 V ... 10 V
  • Max. output voltage
    < 11 V
  • Connection method
    Pluggable spring-cage terminal blocks
  • Test voltage input/output
    1500 V
  • Mounting position
    Max. viewing angle range +/- 45° from the centre line of the display in every direction
  • CSA
    AIS, NI/I/2/ABCDEFG/T4
  • ECLASS 5.0
    27210300
  • ECLASS 10.0.1
    27210301
  • ETIM 4.0
    EC001426
  • ECLASS 6.0
    27210300
  • ECLASS 4.0
    27210300
  • ECLASS 7.0
    27210301
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ETIM 6.0
    EC001426
  • UNSPSC 18.0
    39121008
  • ECLASS 9.0
    27210301
  • ETIM 7.0
    EC001426
  • UNSPSC 13.2
    39121522
  • UNSPSC 21.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo