Phoenix Contact 2906823 Surge protection, consisting of protective plug and base element, with integrated status indicator and knife disconnection for a 3-wire Ex i signal circuit with common reference potential. For HF applications. Indirect grounding via gas-filled surge arres
Phoenix Contact

Part#:2906823

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Surge protection, consisting of protective plug and base element, with integrated status indicator and knife disconnection for a 3-wire Ex i signal circuit with common reference potential. For HF applications. Indirect grounding via gas-filled surge arres

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2906823 Phoenix Contact price in the box on the right side or send a quick quote.

2906823 Product Details

  • Ambient temperature (operation)
    -40 °C ... 35 °C (T6 / 85 °C)
  • Degree of protection
    IP20
  • Rated current
    600 mA (40 °C)
  • Width
    6.2 mm +0.1 mm
  • Permissible humidity (operation)
    5 % ... 95 %
  • Max. input voltage Ui
    30 V DC
  • Nominal voltage UN
    24 V DC
  • Maximum continuous voltage UC
    30 V DC
  • Pulse discharge current Iimp (10/350) µs (line-signalground)
    0.5 kA
  • Voltage protection level Up static (line-line)
    ≤ 75 V (C1 - 1 kV/500 A)
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 8.7 MHz / 150 Ω)
  • Surge protection fault message
    optical
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-line)
    ≤ 600 ms
  • Conductor cross section AWG
    24 ... 12
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 9.0
    27130807
  • Height
    105.8 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Max. internal inductance Li
    negligible
  • Max. input current Ii
    400 mA (T4 / ≤ 50 °C)
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Voltage protection level Up (line-signalground)
    ≤ 80 V (C1 - 1 kV/500 A)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω system
    typ. 60 MHz
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Connection method
    Screw connection
  • Stripping length
    8 mm
  • UL, USA/Canada
    Class I, Div. 2, Groups A, B, C, D T4
  • ECLASS 11.0
    27130807
  • ECLASS 5.1
    27130801
  • ETIM 4.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 19.0
    39121620
  • Altitude
    ≤ 2000 m (amsl (above mean sea level))
  • Insulation voltage to ground
    > 180 V DC
  • Operating effective current IC at UC
    ≤ 5 µA
  • Residual current IPE
    ≤ 1 µA
  • Pulse discharge current Iimp (10/350) µs (line-line)
    0.5 kA
  • Voltage protection level Up (line-earth)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-signalground)
    ≤ 1 ns
  • Capacity (line-signalground)
    typ. 32 pF
  • Resistance per path
    1.65 Ω ±20 %
  • Screw thread
    M3
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 4.1
    27130801
  • ECLASS 4.0
    27140201
  • ETIM 2.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 11
    39121610
  • Depth
    83.5 mm (incl. DIN rail 7.5 mm)
  • Maximum inner capacitance Ci
    negligible
  • IEC test classification
    C1
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Voltage protection level Up static (line-signalground)
    ≤ 75 V (C1 - 1 kV/500 A)
  • Response time tA (line-line)
    ≤ 1 ns
  • Input attenuation aE, asym.
    typ. 0.3 dB (≤ 10.5 MHz / 150 Ω)
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Tightening torque
    0.5 Nm ... 0.6 Nm
  • Standards/specifications
    EN 60079-0 2012 + A11:2013
  • ECLASS 10.0.1
    27130807
  • ECLASS 6.0
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 6.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 21.0
    39121620
  • Nominal discharge current In (8/20) µs (line-signal ground)
    5 kA
  • Voltage protection level Up static (line-earth)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 60 MHz
  • Capacity (line-line)
    typ. 32 pF
  • Max. required back-up fuse
    630 mA (FF)
  • Pulse reset time (line-signalground)
    ≤ 600 ms
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27130801
  • ETIM 3.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 20.0
    39121620
  • UNSPSC 18.0
    39121620
  • ETIM 7.0
    EC000943
  • Voltage protection level Up (line-line)
    ≤ 150 V (C1 - 1 kV/500 A)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo