2906236 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2906236 Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 600 mm in length/190 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on th
Phoenix Contact

Part#:2906236

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Set consisting of a 4-way signal conditioner with push-in connection technology and a Rogowski coil 600 mm in length/190 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on th

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906236 Phoenix Contact price in the box on the right side or send a quick quote.

2906236 Product Details

  • Width
    6.2 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Power consumption
    ≤ 1 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
  • Linearity error
    < 0.1 %
  • Input signal (at 50 Hz)
    100 mV (1000 A)
  • Length of measuring coil
    600 mm
  • Coil material
    Elastollan
  • UL, USA/Canada
    UL 508 Listed
  • Frequency range
    45 Hz ... 65 Hz
  • Connection name
    Measuring transducer side
  • Connection method
    Push-in connection
  • Electromagnetic compatibility
    Conformance with EMC Directive 2004/108/EC
  • Conformance
    CE-compliant
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27210900
  • ECLASS 5.1
    27210900
  • ETIM 6.0
    EC002048
  • UNSPSC 18.0
    39121032
  • UNSPSC 19.0
    39121032
  • Ambient temperature (operation)
    -30 °C ... 80 °C (Measuring coil)
  • Measuring transducer degree of protection
    IP20
  • Output signal (at 50 Hz)
    100 mV (no load, at 1,000 A)
  • Configurable/programmable
    Via DIP switches
  • Diameter of measuring coil
    8.3 mm ±0.2 mm
  • Basic accuracy
    <± 0.2 %
  • Stripping length
    10 mm
  • Noise emission
    EN 61000-6-4
  • Overvoltage category
    II
  • Designation
    CE
  • ECLASS 5.0
    27210900
  • ETIM 3.0
    EC002048
  • ECLASS 9.0
    27210902
  • UNSPSC 20.0
    39121032
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C (Measuring coil)
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Measuring ranges (current)
    100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
  • Voltage output signal
    0 V ... 10 V (via DIP switch)
  • Conductor structure signal line
    2x 0.22 mm (Signal (tinned))
  • Rated insulation voltage
    300 V
  • Maximum transmission error
    ≤ 0.5 % (From the range end value)
  • Conductor cross section AWG
    26 ... 12
  • Pollution degree
    2
  • ECLASS 4.0
    27210900
  • ECLASS 7.0
    27210902
  • UNSPSC 13.2
    39121032
  • UNSPSC 21.0
    39121032
  • Depth
    120.5 mm
  • Maximum altitude
    > 4000 m
  • Nominal supply voltage
    24 V DC
  • Input impedance
    > 100 kΩ
  • Current output signal
    0 mA ... 20 mA (via DIP switch)
  • Output voltage (in no-load operation)
    VOUT = M * dI/dt
  • Housing material
    PBT
  • Standards/regulations
    IEC 61010-1
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Identification
    CE-compliant
  • ECLASS 6.0
    27210900
  • ETIM 4.0
    EC002048
  • Height
    110.5 mm
  • Measuring coil degree of protection
    IP67 (not assessed by UL)
  • Nominal supply voltage range
    9.6 V DC
  • Frequency measuring range
    40 Hz ... 20000 Hz
  • Position error
    <± 1 % (typical)
  • Output voltage (sinusoidal, in no-load operation)
    100 mV (VOUT = 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))
  • Length of signal cable
    3000 mm
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Insulation
    double insulation
  • Test voltage
    3 kV (50 Hz, 1 min.)
  • Typical measuring error
    < 1 %
  • Screw thread
    M3
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 10.0.1
    27210902
  • ECLASS 11.0
    27210902
  • ETIM 7.0
    EC002048

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2906236

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo