About the product: Analog frequency transducer with limit value functionality and plug-in connection technology for converting standard signals into frequency or PWM signals. Configurable via DIP switch or software. Push-in connection technology, order configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2906202 Phoenix Contact price in the box on the right side or send a quick quote.
2906202 Product Details
- Depth 119.2 mm
- Number of inputs 1
- max. input voltage 12 V
- Configurable/programmable Yes
- Max. input current 24 mA
- Frequency output: min. load 4 mA ≤ (UL / RL) ≤ 100 mA
- PWM output: signal 15.6 kHz (10 bits, via DIP switch)
- Connection method Push-in connection
- Conductor cross section solid 0.2 mm² ... 2.5 mm² (with ferrule)
- Maximum temperature coefficient < 0.01 %/K
- Electromagnetic compatibility Conformance with EMC directive
- Color gray
- Conformance CE-compliant
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -40 °C ... 70 °C
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Width 6.2 mm
- Degree of protection IP20 (not assessed by UL)
- Input resistance of voltage input > 120 kΩ
- Min. switching current 100 µA
- Load current maximum 100 mA
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Typical current consumption 27 mA (12 V DC)
- Temperature coefficient, typical 0.01 %/K
- Degree of pollution 2
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- ATEX II 3 G Ex nA IIC T4 Gc X
- DNV GL-EMC A
- Identification UL 508 Listed
- ECLASS 10.0.1 27210120
- Height 109.81 mm
- Maximum altitude ≤ 2000 m
- Mounting position any
- DNV GL-Vibration A
- Designation Shipbuilding approval
- Current input signal 0 mA ... 20 mA (via DIP switch)
- Number of outputs 1
- Overrange/underrange Can be set (via software)
- Power consumption ≤ 350 mW (9.6 V DC)
- Vibration A
- EMC A
- Conductor cross section AWG 24 ... 12 (flexible)
- Overvoltage category II
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Rated insulation voltage 300 V (effective)
- Housing material PBT
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- UL, USA/Canada UL 508 Listed
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Voltage input signal 0 V ... 10 V (via DIP switch)
- Input resistance current input approx. 50 Ω (+0.7 V for test diode)
- Minimum switching voltage 1 V DC
- Max. switching current 100 mA (30 V DC)
- PWM output: min. load 12 mA ≤ (UL / RL) ≤ 100 mA
- Step response (0–99%) 120 ms (15 Hz sample rate)
- Stripping length 10 mm
- No. of channels 1
- Frequency output: signal 0 Hz ... 10 kHz (via DIP switch)
- Nominal supply voltage 24 V DC
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Noise emission EN 61000-6-4
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Output name Frequency output / switching output
- Maximum switching voltage 30 V DC
- DNV GL-Temperature B
- Temperature B
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27210100
- ECLASS 5.1 27210100
- ECLASS 9.0 27210120
- UNSPSC 19.0 39121008
- DNV GL-Humidity B
- Certificate DNV GL TAA000021E
- Humidity B
- ECLASS 4.1 27210100
- ECLASS 6.0 27210100
- UNSPSC 13.2 39121008
- UNSPSC 20.0 39121008
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- China RoHS Environmentally Friendly Use Period = 50 years
- UNSPSC 18.0 39121008
- ETIM 4.0 EC002653
- ECLASS 11.0 27210120
- ECLASS 5.0 27210100
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ETIM 6.0 EC002653
- ECLASS 7.0 27210120
- UNSPSC 21.0 39121008
- ETIM 7.0 EC002653
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2906202
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨