2905248 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2905248 Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, order configuration
Phoenix Contact

Part#:2905248

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Push-in connection technology, order configuration

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2905248 Phoenix Contact price in the box on the right side or send a quick quote.

2905248 Product Details

  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Voltage output signal
    0 V ... 5 V (via DIP switch)
  • Short-circuit current
    < 31.5 mA
  • Typical current consumption
    32.7 mA (24 V DC)
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Configurable/programmable
    Yes
  • Current output signal
    0 mA ... 20 mA (via DIP switch)
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Width
    6.2 mm
  • Degree of protection
    IP20 (not assessed by UL)
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Height
    109.81 mm
  • Number of outputs
    1
  • Max. output current
    24.6 mA
  • Connection method
    Push-in connection
  • ECLASS 5.1
    27200200
  • ETIM 4.0
    EC001446
  • UNSPSC 11
    39121008
  • UNSPSC 20.0
    41112105
  • Typical deviation from the measuring range final value
    0.05 %
  • Load/output load voltage output
    ≥ 10 kΩ
  • Power consumption
    ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm² (with ferrule)
  • Maximum temperature coefficient
    ≤ 0.01 %/K
  • Transmission error thermocouples
    0.1% * 600 K / set measuring range; 0.1% > 600 K (C, E, J, K, N, T, L, U, M Gost, L Gost)
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Conformance
    CE-compliant
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • UNSPSC 6.01
    30211506
  • UNSPSC 12.01
    39121008
  • ECLASS 7.0
    27200206
  • UNSPSC 7.0901
    39121008
  • ETIM 6.0
    EC002919
  • ECLASS 4.0
    27200200
  • ECLASS 11.0
    27210129
  • UNSPSC 18.0
    41112105
  • UNSPSC 19.0
    41112105
  • UL, USA/Canada
    UL 508 Listed
  • ETIM 3.0
    EC001446
  • Standards/regulations
    EN 61000-4-6
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Depth
    119.2 mm
  • Max. output voltage
    approx. 12.3 V
  • Stripping length
    10 mm
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Typical cold point errors
    2 K (2 K + (0,2 K * ΔT))
  • Degree of pollution
    2
  • Rated insulation voltage
    300 V (effective)
  • Designation
    Shipbuilding approval
  • Certificate
    DNV GL 14445-15HH
  • ECLASS 10.0.1
    27210129
  • ETIM 7.0
    EC002919
  • UNSPSC 13.2
    41112105
  • UNSPSC 21.0
    41112105
  • Sensor types that can be used (TC)
    B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
  • Ripple
    < 10 mVrms
  • Supply voltage range
    9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Overvoltage category
    II
  • Assembly instructions
    The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
  • ATEX
     II 3 G Ex nA IIC T4 Gc X
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27200200
  • ECLASS 5.0
    27200200
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Temperature measuring range
    -250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Housing material
    PBT
  • Mounting position
    any
  • ECLASS 9.0
    27210129
  • Protective circuit
    Transient protection
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Noise emission
    EN 61000-6-4
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Identification
    C, EMC2
  • ECLASS 6.0
    27200200
  • ETIM 2.0
    EC001446

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo