2905027 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2905027
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, order configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2905027 Phoenix Contact price in the box on the right side or send a quick quote.
2905027 Product Details
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Degree of protection IP20 (not assessed by UL)
- Voltage input signal 0 V ... 10 V (via DIP switch)
- Max. output voltage approx. 12.3 V
- Identification UL 508 Listed
- Depth 119.2 mm
- Maximum altitude ≤ 2000 m
- Current input signal 0 mA ... 20 mA (via DIP switch)
- Height 109.81 mm
- Number of inputs 1
- Max. input current 24 mA
- Load/output load voltage output ≥ 10 kΩ
- Nominal supply voltage 24 V DC
- Connection method Push-in connection
- Degree of pollution 2
- Color gray
- Electromagnetic compatibility Conformance with EMC directive
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- UL, USA/Canada UL 508 Listed
- DNV GL-EMC A
- Certificate DNV GL TAA000021E
- REACh SVHC Lead 7439-92-1
- Ambient temperature (operation) -40 °C ... 70 °C
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Input resistance current input approx. 50 Ω (+0.7 V for test diode)
- Max. output current 24.6 mA
- Typical current consumption 55 mA (24 V DC)
- Stripping length 10 mm
- Conductor cross section AWG 24 ... 12 (flexible)
- Housing material PBT
- Noise emission EN 61000-6-4
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- DNV GL-Temperature B
- Vibration A
- Humidity B
- ECLASS 5.1 27210100
- ETIM 6.0 EC002653
- Width 6.2 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- max. input voltage 12 V
- Voltage output signal 0 V ... 10 V (via DIP switch)
- Number of outputs 2
- Short-circuit current ≤ 25 mA
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Maximum transmission error 0.05 % (of final value)
- Mounting position any
- Load/output load current output ≤ 600 Ω (per channel)
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Conductor cross section solid 0.2 mm² ... 2.5 mm² (with ferrule)
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Maximum temperature coefficient 0.01 %/K
- Rated insulation voltage 300 V
- Conformance CE-compliant
- Standards/regulations EN 61000-4-6
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- EMC A
- ECLASS 4.1 27210100
- ETIM 4.0 EC002653
- UNSPSC 18.0 39121008
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27210120
- ECLASS 9.0 27210120
- UNSPSC 6.01 30211506
- UNSPSC 13.2 39121008
- DNV GL-Humidity B
- ECLASS 4.0 27210100
- ETIM 7.0 EC002653
- ECLASS 5.0 27210100
- UNSPSC 19.0 39121008
- UNSPSC 12.01 39121008
- UNSPSC 11 39121008
- UNSPSC 21.0 39121008
- Configurable/programmable Yes
- Current output signal 0 mA ... 20 mA (via DIP switch)
- Ripple < 20 mVPP (at 600 Ω)
- No. of channels 2
- Typical deviation from the measuring range final value 2.8 %
- UNSPSC 7.0901 39121008
- UNSPSC 20.0 39121008
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 7.0 27210120
- Input resistance of voltage input > 120 kΩ
- Overvoltage category II
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- ECLASS 6.0 27210100
- Designation Shipbuilding approval
- ATEX II 3 G Ex nA IIC T4 Gc X
- Power consumption ≤ 1.5 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
- DNV GL-Vibration A
- Temperature B
- ECLASS 10.0.1 27210120
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2905027
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨