2904605 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2904605 Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 2.5 A
Phoenix Contact

Part#:2904605

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 2

04/19/2024

About the product: Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 2.5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2904605 Phoenix Contact price in the box on the right side or send a quick quote.

2904605 Product Details

  • Depth
    90 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Degree of pollution
    2
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Current consumption
    0.44 A (100 V AC)
  • Inrush current
    typ. 11.3 A (at 25 °C)
  • Nominal output voltage
    12 V DC
  • Protective circuit/component
    Varistor
  • Feedback voltage resistance
    ≤ 25 V DC
  • Residual ripple
    < 30 mVPP (with nominal values)
  • Maximum power dissipation in no-load condition
    < 0.4 W (230 V AC)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG min.
    24
  • Width
    22.5 mm
  • Installation distance right/left (active)
    15 mm / 15 mm (POut ≥50% )
  • Degree of protection
    IP20
  • Protection class
    II
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    14
  • Standard - Safe isolation
    IEC 61558-2-16
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Noise emission
    EN 55016
  • Frequency range
    50 Hz ... 60 Hz
  • Discharge in air
    15 kV (Test Level 4)
  • Output
    1 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • Voltage dips
    EN 61000-4-11
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 7.0
    27049002
  • UNSPSC 18.0
    39121004
  • Height
    106 mm
  • Installation distance top/bottom (active, passive)
    30 mm / 30 mm (POut ≤50 %)
  • Installation distance top/bottom (passive)
    30 mm / 30 mm (POut ≥50% )
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Discharge current to PE
    < 0.25 mA (264 V AC, 60 Hz)
  • Nominal power consumption
    32.8 VA
  • Type of protection
    Transient surge protection
  • Static Boost (IStat.Boost)
    3.125 A (≤ 40 °C)
  • Output power
    30 W
  • Typical response time
    500 ms
  • Net weight
    0.181 kg
  • MTBF (IEC 61709, SN 29500)
    > 1848000 h (25 °C)
  • Conductor cross section solid min.
    0.2 mm²
  • Standard - Safety of transformers
    EN 61558-2-16
  • Stripping length
    10 mm
  • SIQ
    CB-Scheme (IEC 61010-1, IEC 61010-2-201)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    1000 A/m
  • Signal
    0.5 kV (Test Level 2 - symmetrical)
  • Voltage dip
    0 %
  • Test level 1
    16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • ECLASS 11.0
    27040701
  • ETIM 7.0
    EC002540
  • UNSPSC 20.0
    39121004
  • Installation distance right/left (passive)
    5 mm / 5 mm (POut ≥50% )
  • Installation distance top/bottom (active)
    30 mm / 30 mm (POut ≥50% )
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Installation height
    ≤ 5000 m (> 2000 m, observe derating)
  • Mains buffering time
    typ. 54 ms (120 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristic B, C or comparable)
  • Nominal output current (IN)
    2.5 A
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Connection in series
    yes
  • Control deviation
    < 0.2 % (Static load change 10 % ... 90 %)
  • Power loss nominal load max.
    < 3.5 W (120 V AC)
  • Efficiency
    typ. 89.5 % (120 V AC)
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    2.5 mm²
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • UL approvals
    UL Listed UL 61010-1
  • Harmonic currents
    EN 61000-3-2
  • Contact discharge
    8 kV (Test Level 4)
  • Input
    2 kV (symmetrical)
  • Frequency
    60 Hz
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Attenuated oscillating wave
    EN 61000-4-18
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 6.0
    27049000
  • ETIM 6.0
    EC002540
  • UNSPSC 21.0
    39121004
  • Installation distance right/left (active, passive)
    0 mm / 0 mm (POut ≤50 %)
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Dielectric strength maximum
    300 V AC 60 s
  • Frequency range (fN)
    50 Hz ... 60 Hz -10 % ... +10 %
  • Input fuse
    3.15 A (slow-blow, internal)
  • Setting range of the output voltage (USet)
    12 V DC ... 15 V DC (constant capacity)
  • Dynamic Boost (IDyn.Boost)
    4.5 A (≤ 60 °C (5 s))
  • Protection against overvoltage at the output (OVP)
    ≤ 18 V DC
  • Fast transients (burst)
    EN 61000-4-4
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage
    1 kV (symmetrical)
  • Additional text
    Test Level 2
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 2)
  • ECLASS 5.1
    27242213
  • ECLASS 9.0
    27040701
  • UNSPSC 19.0
    39121004
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Conducted noise emission
    EN 55016
  • Flicker
    EN 61000-3-3
  • Electromagnetic HF field
    EN 61000-4-3
  • Comments
    Criterion A
  • Conducted interference
    EN 61000-4-6
  • Power frequency magnetic field
    EN 61000-4-8
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • UNSPSC 13.2
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 5 days!

1-year warranty

$154.53

2904605

Stock:

2

Select Qty:

$154.53

$154.53 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo