2903160 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903160 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 48 V DC/10 A
Phoenix Contact

Part#:2903160

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 15

04/19/2024

About the product: Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 48 V DC/10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903160 Phoenix Contact price in the box on the right side or send a quick quote.

2903160 Product Details

  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Output power
    480 W
  • Peak switching voltages nominal load
    < 1000 mVPP
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section solid max.
    1.5 mm²
  • Stripping length
    8 mm
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    0.15 MHz ... 80 MHz
  • Conducted interference
    EN 61000-4-6
  • ECLASS 11.0
    27040701
  • ECLASS 9.0
    27040701
  • UNSPSC 20.0
    39121004
  • Width
    68 mm
  • Depth
    160 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Ambient temperature (start-up type tested)
    -40 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Current consumption
    5.6 A (100 V AC)
  • Mains buffering time
    typ. 10 ms (120 V AC)
  • Power factor (cos phi)
    0.85
  • Nominal output current (IN)
    10 A
  • Connection in series
    yes
  • Typical response time
    < 1 s
  • Installation distance top/bottom
    50 mm / 50 mm
  • Degree of protection
    IP20
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Dielectric strength maximum
    ≤ 300 V AC 15 s
  • Discharge current to PE
    < 3.5 mA
  • Inrush current
    20 A (at 25 °C)
  • Input fuse
    10 A (internal (device protection))
  • Dynamic Boost (IDyn.Boost)
    15 A (5 s)
  • Feedback voltage resistance
    ≤ 60 V DC
  • Maximum power dissipation in no-load condition
    < 5.7 W (230 V)
  • Insulation voltage input/output
    3 kV AC
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Contact discharge
    6 kV (Test Level 4)
  • Test field strength
    10 V/m (Test Level 3)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • ECLASS 4.1
    27040702
  • ETIM 4.0
    EC002540
  • ETIM 7.0
    EC002540
  • UNSPSC 21.0
    39121004
  • Height
    130 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Nominal power consumption
    604.7 VA
  • Protective circuit/component
    Varistor
  • Setting range of the output voltage (USet)
    36 V DC ... 55 V DC (> 48 V DC, constant capacity restricted)
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Net weight
    1.4 kg
  • Protection class
    I (in closed control cabinet)
  • Connection method
    Push-in connection
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Rail applications
    EN 50121-4
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Discharge in air
    8 kV (Test Level 4)
  • Comments
    Criterion A
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • I/O/S
    asymmetrical
  • REACh SVHC
    Lead 7439-92-1
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.1
    27049002
  • ETIM 6.0
    EC002540
  • UNSPSC 13.2
    39121004
  • UNSPSC 19.0
    39121004
  • Installation height
    ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Recommended breaker for input protection
    10 A ... 16 A (Characteristics B, C, D, K)
  • Type of protection
    Transient surge protection
  • Nominal output voltage
    48 V DC ±1 %
  • Protection against overvoltage at the output (OVP)
    ≤ 60 V DC
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Power loss nominal load max.
    < 44 W
  • MTBF (IEC 61709, SN 29500)
    > 1800000 h (25 °C)
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Input
    3 kV (Test Level 3 - symmetrical)
  • Voltage
    10 V (Test Level 3)
  • ECLASS 5.0
    27049002
  • ECLASS 7.0
    27049002
  • Efficiency
    > 93 % (for 230 V AC and nominal values)
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section flexible max.
    1.5 mm²
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • UL approvals
    UL Listed UL 508
  • Electromagnetic HF field
    EN 61000-4-3
  • Fast transients (burst)
    EN 61000-4-4
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 4.0
    27040702
  • ECLASS 6.0
    27049000
  • UNSPSC 18.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$405.53

2903160

Stock:

15

Select Qty:

$405.53

$405.53 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo