Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2903159 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903159 Primary-switched TRIO power supply for DIN rail mounting, input: 1-phase, output: 48 V DC / 5 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule
Phoenix Contact

Part#:2903159

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 8

04/16/2024

About the product: Primary-switched TRIO power supply for DIN rail mounting, input: 1-phase, output: 48 V DC / 5 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903159 Phoenix Contact price in the box on the right side or send a quick quote.

2903159 Product Details

  • Installation distance right/left
    0 mm / 0 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Mains buffering time
    typ. 15 ms (120 V AC)
  • Nominal output voltage
    48 V DC ±1 %
  • Dynamic Boost (IDyn.Boost)
    7.5 A (5 s)
  • Feedback voltage resistance
    ≤ 60 V DC
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Short-circuit current
    < 7 A DC (Permanent)
  • Efficiency
    typ. 90.5 % (120 V AC)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section solid max.
    1.5 mm²
  • Stripping length
    8 mm
  • Standard - Safety of power supply units up to 1100 V (insulation distances)
    DIN EN 61558-2-16
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Degree of pollution
    2
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 4.0
    27040702
  • Depth
    160 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Ambient temperature (start-up type tested)
    -40 °C
  • Dielectric strength maximum
    ≤ 300 V AC 15 s
  • Discharge current to PE
    < 3.5 mA
  • Nominal power consumption
    285.7 VA
  • Nominal output current (IN)
    5 A
  • Protection against overvoltage at the output (OVP)
    ≤ 60 V DC
  • Output power
    240 W
  • Peak switching voltages nominal load
    < 15 mVPP
  • Connection method
    Push-in connection
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section AWG max.
    16
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Rail applications
    EN 50121-4
  • Conducted noise emission
    EN 55016
  • Electromagnetic HF field
    EN 61000-4-3
  • Fast transients (burst)
    EN 61000-4-4
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • I/O/S
    asymmetrical
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • ECLASS 5.0
    27049002
  • ETIM 4.0
    EC002540
  • UNSPSC 20.0
    39121004
  • UNSPSC 21.0
    39121004
  • Number of periods
    1 period
  • Height
    130 mm
  • Degree of protection
    IP20
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Installation height
    ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
  • Frequency range (fN)
    50 Hz ... 60 Hz ±5 Hz
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Setting range of the output voltage (USet)
    36 V DC ... 55 V DC (> 48 V DC, constant capacity restricted)
  • Connection in series
    yes
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Maximum power dissipation in no-load condition
    typ. 4 W (120 V AC)
  • Power loss nominal load max.
    typ. 24.5 W (120 V AC)
  • Insulation voltage input/output
    3 kV AC (type test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Noise emission
    EN 55016
  • Test field strength
    10 V/m (Test Level 3)
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Frequency
    50 Hz
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 11.0
    27040701
  • ECLASS 7.0
    27049002
  • ETIM 7.0
    EC002540
  • Width
    42 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Current consumption
    2.9 A (100 V AC)
  • Input fuse
    6.3 A (internal (device protection))
  • Power factor (cos phi)
    0.91
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Residual ripple
    < 20 mVPP (with nominal values)
  • Net weight
    0.9 kg
  • MTBF (IEC 61709, SN 29500)
    > 2000000 h (25 °C)
  • Protection class
    I (in closed control cabinet)
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Contact discharge
    6 kV (Test Level 4)
  • Discharge in air
    8 kV (Test Level 4)
  • Comments
    Criterion A
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage
    230 V AC
  • Voltage dip
    0 %
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27040702
  • ECLASS 9.0
    27040701
  • UNSPSC 13.2
    39121004
  • EMC requirements for noise emission
    EN 61000-6-3
  • UL approvals
    UL Listed UL 508
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    0.15 MHz ... 80 MHz
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-11
  • Additional text
    Test Level 2
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.1
    27049002
  • ETIM 6.0
    EC002540
  • UNSPSC 18.0
    39121004
  • ECLASS 6.0
    27049000
  • UNSPSC 19.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$268.36

2903159

Stock:

8

Select Qty:

$268.36

$268.36 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo