Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2903158 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903158 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12 V DC/10 A
Phoenix Contact

Part#:2903158

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12 V DC/10 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903158 Phoenix Contact price in the box on the right side or send a quick quote.

2903158 Product Details

  • Width
    35 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Degree of protection
    IP20
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Degree of pollution
    2
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Dielectric strength maximum
    ≤ 300 V AC 15 s
  • Nominal power consumption
    254.7 VA
  • Input fuse
    6.3 A Fast blow (internal (device protection))
  • Type of protection
    Transient surge protection
  • Nominal output voltage
    12 V DC ±1 %
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Protection against overvoltage at the output (OVP)
    ≤ 22 V DC
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Height
    130 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Ambient temperature (start-up type tested)
    -25 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Discharge current to PE
    < 0.25 mA
  • Inrush current
    ≤ 30 A (typical)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Protective circuit/component
    Varistor
  • Setting range of the output voltage (USet)
    12 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
  • Dynamic Boost (IDyn.Boost)
    15 A (5 s)
  • Feedback voltage resistance
    < 25 V
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Typical response time
    < 1 s
  • Net weight
    0.4 kg
  • Efficiency
    typ. 87.5 % (120 V AC)
  • MTBF (IEC 61709, SN 29500)
    > (25 °C)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    1.5 mm²
  • Conductor cross section AWG min.
    24
  • Conductor cross section AWG max.
    16
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Rail applications
    EN 50121-4
  • UL approvals
    UL Listed UL 508
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Depth
    115 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Installation height
    ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Current consumption
    2.2 A (100 V AC)
  • Mains buffering time
    typ. 20 ms (120 V AC)
  • Power factor (cos phi)
    0.53
  • Nominal output current (IN)
    10 A
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Connection in series
    yes
  • Output power
    120 W
  • Maximum power dissipation in no-load condition
    < 1 W (230 V)
  • Power loss nominal load max.
    < 15 W (230 V)
  • Insulation voltage input/output
    3 kV AC (type test)
  • Protection class
    II (in closed control cabinet)
  • Housing material
    PC
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    8 mm
  • EMC requirements for noise immunity
    EN 61000-6-1
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    6 kV (Test Level 3)
  • Test field strength
    10 V/m (Test Level 3)
  • Comments
    Criterion A
  • Fast transients (burst)
    EN 61000-4-4
  • Surge voltage load (surge)
    EN 61000-4-5
  • Conducted interference
    EN 61000-4-6
  • Voltage
    230 V AC
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • REACh SVHC
    Lead 7439-92-1
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 4.1
    27040702
  • ECLASS 5.0
    27049002
  • ECLASS 5.1
    27049002
  • ETIM 4.0
    EC002540
  • ETIM 6.0
    EC002540
  • UNSPSC 13.2
    39121004
  • UNSPSC 19.0
    39121004
  • UNSPSC 20.0
    39121004
  • Discharge in air
    8 kV (Test Level 3)
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    0.15 MHz ... 80 MHz
  • Input
    3 kV (Test Level 4 - symmetrical)
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Voltage dips
    EN 61000-4-11
  • Frequency
    50 Hz
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27040701
  • ECLASS 11.0
    27040701
  • ECLASS 4.0
    27040702
  • ECLASS 6.0
    27049000
  • ECLASS 7.0
    27049002
  • ECLASS 9.0
    27040701
  • ETIM 7.0
    EC002540
  • UNSPSC 18.0
    39121004
  • UNSPSC 21.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2903158

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo