Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2903157 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903157 Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12 V DC/5 A C2LPS
Phoenix Contact

Part#:2903157

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 1

04/19/2024

About the product: Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12 V DC/5 A C2LPS

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903157 Phoenix Contact price in the box on the right side or send a quick quote.

2903157 Product Details

  • Degree of protection
    IP20
  • Degree of pollution
    2
  • Nominal power consumption
    137.3 VA
  • Type of protection
    Transient surge protection
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Power loss nominal load max.
    < 10 W (230 V)
  • Housing material
    PC
  • Conductor cross section flexible max.
    1.5 mm²
  • UL approvals
    UL Listed UL 508
  • Electromagnetic HF field
    EN 61000-4-3
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ECLASS 10.0.1
    27040701
  • ECLASS 6.0
    27049000
  • ETIM 4.0
    EC002540
  • ECLASS 9.0
    27040701
  • UNSPSC 21.0
    39121004
  • Depth
    115 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Dielectric strength maximum
    ≤ 300 V AC 15 s
  • Current consumption
    1.1 A (100 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • Setting range of the output voltage (USet)
    12 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
  • Feedback voltage resistance
    < 25 V
  • Output power
    60 W
  • Efficiency
    > 86 % (for 230 V AC and nominal values)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section solid max.
    1.5 mm²
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Rail applications
    EN 50121-4
  • Discharge in air
    8 kV (Test Level 3)
  • Test field strength
    10 V/m (Test Level 3)
  • Fast transients (burst)
    EN 61000-4-4
  • Height
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Ambient temperature (start-up type tested)
    -25 °C
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    100 V AC ... 240 V AC -15 % ... +10 %
  • Discharge current to PE
    < 0.25 mA
  • Mains buffering time
    typ. 20 ms (120 V AC)
  • Power factor (cos phi)
    0.51
  • Nominal output current (IN)
    5 A
  • Connection in series
    yes
  • Width
    30 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Inrush current
    ≤ 25 A (typical)
  • Protective circuit/component
    Varistor
  • Protection against overvoltage at the output (OVP)
    ≤ 22 V DC
  • Net weight
    0.32 kg
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section AWG max.
    16
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Comments
    Criterion A
  • Conducted interference
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 4.0
    27040702
  • ECLASS 5.1
    27049002
  • ETIM 7.0
    EC002540
  • UNSPSC 13.2
    39121004
  • UNSPSC 19.0
    39121004
  • Installation distance right/left
    0 mm / 0 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Installation height
    ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Input fuse
    6.3 A Slow-blow
  • Nominal output voltage
    12 V DC ±1 %
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Maximum power dissipation in no-load condition
    < 1 W (230 V)
  • Insulation voltage input/output
    3 kV AC (type test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    6 kV (Test Level 3)
  • Input
    3 kV (Test Level 4 - symmetrical)
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Voltage dips
    EN 61000-4-11
  • Frequency
    50 Hz
  • ECLASS 5.0
    27049002
  • ECLASS 4.1
    27040702
  • ECLASS 7.0
    27049002
  • ETIM 6.0
    EC002540
  • UNSPSC 18.0
    39121004
  • UNSPSC 20.0
    39121004
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Typical response time
    < 1 s
  • MTBF (IEC 61709, SN 29500)
    25 °C
  • Protection class
    II (in closed control cabinet)
  • Connection method
    Push-in connection
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    8 mm
  • Standard - Safety of transformers
    EN 61558-2-16 (air clearances and creepage distances only)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electrostatic discharge
    EN 61000-4-2
  • Frequency range
    0.15 MHz ... 80 MHz
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Voltage
    230 V AC
  • Criterion A
    Normal operating behavior within the specified limits.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 3 days!

1-year warranty

$163.01

2903157

Stock:

1

Select Qty:

$163.01

$163.01 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo