2903156 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2903156 Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 24 V DC/40 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule
Phoenix Contact

Part#:2903156

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 24 V DC/40 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule

About the category: AC/DC power supplies are power supplies that convert alternating current from the grid into direct current that is needed to power most electronics. AC/DC power supplies are integral components in systems that make the world go round.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2903156 Phoenix Contact price in the box on the right side or send a quick quote.

2903156 Product Details

  • Width
    110 mm
  • Height
    130 mm
  • Depth
    160 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Degree of protection
    IP20
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Degree of pollution
    2
  • Input voltage range
    3x 400 V AC ... 500 V AC -20 % ....+15 %
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • Nominal power consumption
    1335.1 VA
  • Mains buffering time
    > 10 ms (400 V AC)
  • Type of protection
    Transient surge protection
  • Nominal output voltage
    24 V DC ±1 %
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Voltage
    230 V AC
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 6.0
    27049000
  • ECLASS 9.0
    27040701
  • UNSPSC 20.0
    39121004
  • Current consumption
    3x 1.9 A (400 V AC)
  • Input fuse
    6.3 A (internal (device protection))
  • Nominal output current (IN)
    40 A
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Output power
    960 W
  • Typical response time
    < 1 s
  • Protection class
    I (in closed control cabinet)
  • Insulation voltage input/output
    3 kV AC (type test)
  • Connection method
    Push-in connection
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Safety of power supply units up to 1100 V (insulation distances)
    DIN EN 61558-2-16
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Power factor (cos phi)
    0.77
  • Protective circuit/component
    Varistor
  • Feedback voltage resistance
    < 35 V
  • Residual ripple
    ≤ 50 mVPP
  • Power loss nominal load max.
    < 70 W (480 V AC)
  • MTBF (IEC 61709, SN 29500)
    > 1730000 h (25 °C)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Noise emission
    EN 55016
  • Electrostatic discharge
    EN 61000-4-2
  • Fast transients (burst)
    EN 61000-4-4
  • Input
    3 kV (Test Level 4 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 11.0
    27040701
  • ECLASS 7.0
    27049002
  • ETIM 6.0
    EC002540
  • UNSPSC 18.0
    39121004
  • Ambient temperature (start-up type tested)
    -40 °C
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Installation height
    ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
  • AC frequency range
    50 Hz ... 60 Hz
  • Frequency range (fN)
    50 Hz ... 60 Hz ±5 Hz
  • Discharge current to PE
    < 3.5 mA
  • Recommended breaker for input protection
    10 A ... 16 A (Characteristics B, C, D, K)
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Connection in series
    yes
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Short-circuit current
    < 48 A DC (Permanent)
  • Efficiency
    typ. 93 % (400 V AC)
  • Assembly instructions
    alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise emission
    EN 61000-6-3
  • Rail applications
    EN 50121-4
  • UL approvals
    UL Listed UL 508
  • Discharge in air
    8 kV (Test Level 3)
  • Frequency range
    0.15 MHz ... 80 MHz
  • Comments
    Criterion A
  • Frequency
    50 Hz
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.0
    27049000
  • ETIM 7.0
    EC002540
  • UNSPSC 19.0
    39121004
  • Dynamic Boost (IDyn.Boost)
    60 A (5 s)
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Maximum power dissipation in no-load condition
    typ. 14 W (400 V AC)
  • Net weight
    2.6 kg
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • Stripping length
    8 mm
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Contact discharge
    6 kV (Test Level 3)
  • Test field strength
    10 V/m (Test Level 3)
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • ECLASS 10.0.1
    27040701
  • ECLASS 4.1
    27040700
  • ETIM 4.0
    EC002540
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Conducted noise emission
    EN 55016
  • Electromagnetic HF field
    EN 61000-4-3
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-11
  • ECLASS 4.0
    27040700
  • ECLASS 5.1
    27049000
  • UNSPSC 13.2
    39121004
  • UNSPSC 21.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo