Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2902062 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2902062 Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input configurable via DIP switch. Push-in connection technology, order configuration.
Phoenix Contact

Part#:2902062

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Output loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of unipolar and bipolar analog signals. Input configurable via DIP switch. Push-in connection technology, order configuration.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2902062 Phoenix Contact price in the box on the right side or send a quick quote.

2902062 Product Details

  • Height
    109.81 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Configurable/programmable
    Yes
  • Number of outputs
    1
  • Current output signal
    4 mA ... 20 mA
  • Power consumption
    ≤ 600 mW
  • Supply voltage range
    8 V DC ... 30 V DC (no separate supply voltage necessary)
  • Maximum temperature coefficient
    0.01 %/K
  • Temperature coefficient, typical
    0.005 %/K
  • Depth
    119.2 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Number of inputs
    1
  • Input resistance of voltage input
    approx. 100 kΩ (At ≤ 1 V, otherwise approximately 1 MΩ)
  • Max. output current
    32 mA
  • Stripping length
    10 mm
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm² (with ferrule)
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • Test voltage, input/output/supply
    3 kV (50 Hz, 1 min.)
  • Noise emission
    EN 61000-6-4
  • Mounting position
    any
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Maximum altitude
    ≤ 2000 m
  • Degree of protection
    IP20 (not assessed by UL)
  • Max. input current
    50 mA (Dielectric strength up to 30 V)
  • Ripple
    < 10 mVrms (at 600 Ω)
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 12 (flexible)
  • Maximum transmission error
    ≤ 0.1 % (of final value)
  • Step response (10-90%)
    20 ms
  • Rated insulation voltage
    300 V (effective)
  • Housing material
    PBT
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 2
  • Identification
    UL 508 Listed
  • Vibration
    A
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27210100
  • ECLASS 6.0
    27210100
  • ECLASS 7.0
    27210120
  • UNSPSC 21.0
    39121008
  • Width
    6.2 mm
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Load/output load current output
    < 1000 Ω ((UB - 8 V) / 22 mA)
  • Input resistance current input
    25 Ω (+0.7 V for test diode)
  • Typical current consumption
    ≤ 20 mA
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • No. of channels
    1
  • Limit frequency (3 dB)
    approx. 30 Hz
  • Degree of pollution
    2
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 2
  • Designation
    Shipbuilding approval
  • Humidity
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27210100
  • ECLASS 11.0
    27210120
  • UNSPSC 13.2
    39121008
  • UNSPSC 18.0
    39121008
  • Overvoltage category
    II
  • Color
    gray
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 2
  • Certificate
    DNV GL TAA000021E
  • EMC
    A
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.0
    27210100
  • ECLASS 9.0
    27210120
  • ETIM 7.0
    EC002653
  • UNSPSC 20.0
    39121008
  • Standards/regulations
    GB 3836.1
  • Temperature
    B
  • ECLASS 10.0.1
    27210120
  • ECLASS 5.0
    27210100
  • ETIM 4.0
    EC002653
  • ETIM 6.0
    EC002653
  • UNSPSC 19.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2902062

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo