2902053 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2902053
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Configurable temperature transducer with plug-in connection technology for connecting thermocouples. Configurable via DIP switch or software. Screw connection technology, order configuration
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902053 Phoenix Contact price in the box on the right side or send a quick quote.
2902053 Product Details
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Configurable/programmable Yes
- Load/output load voltage output ≥ 10 kΩ
- Width 6.2 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Sensor types that can be used (TC) B, C, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
- Number of outputs 1
- Max. output current 24.6 mA
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Connection method Screw connection
- Stripping length 10 mm
- Torque 0.5 Nm ... 0.6 Nm
- Height 109.81 mm
- Degree of protection IP20 (not assessed by UL)
- Screw thread M3
- Max. output voltage approx. 12.3 V
- Depth 119.2 mm
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Protective circuit Transient protection
- Rated insulation voltage 300 V (effective)
- Electromagnetic compatibility Conformance with EMC directive
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
- Standards/regulations EN 61000-4-6
- Typical deviation from the measuring range final value 0.05 %
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27210129
- ECLASS 4.1 27200200
- ECLASS 6.0 27200200
- ECLASS 9.0 27210129
- ETIM 3.0 EC001446
- ETIM 6.0 EC002919
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Ripple < 10 mVrms
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Degree of pollution 2
- Noise emission EN 61000-6-4
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- UL, USA/Canada UL 508 Listed
- Identification C, EMC2
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27200200
- ECLASS 5.0 27200200
- ETIM 2.0 EC001446
- UNSPSC 6.01 30211506
- UNSPSC 12.01 39121008
- UNSPSC 18.0 41112105
- UNSPSC 20.0 41112105
- UNSPSC 19.0 41112105
- UNSPSC 13.2 41112105
- Mounting position any
- ECLASS 10.0.1 27210129
- ETIM 4.0 EC001446
- UNSPSC 21.0 41112105
- ATEX II 3 G Ex nA IIC T4 Gc X
- ECLASS 5.1 27200200
- ETIM 7.0 EC002919
- UNSPSC 7.0901 39121008
- Certificate DNV GL 14445-15HH
- ECLASS 7.0 27200206
- UNSPSC 11 39121008
- Conformance CE-compliant
- Conductor cross section solid 0.2 mm² ... 1.5 mm² (with ferrule)
- Maximum temperature coefficient ≤ 0.01 %/K
- Overvoltage category II
- Housing material PBT
- Current output signal 0 mA ... 20 mA (via DIP switch)
- Conductor cross section AWG 24 ... 12 (flexible)
- Typical cold point errors 2 K (2 K + (0,2 K * ΔT))
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Short-circuit current < 31.5 mA
- Typical current consumption 32.7 mA (24 V DC)
- Transmission error thermocouples 0.1% * 600 K / set measuring range; 0.1% > 600 K (C, E, J, K, N, T, L, U, M Gost, L Gost)
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- Designation Shipbuilding approval
- Ambient temperature (operation) -40 °C ... 70 °C
- Temperature measuring range -250 °C ... 2500 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 1350°C via DIP switches)
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- Voltage output signal 0 V ... 5 V (via DIP switch)
- Power consumption ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2902053
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨