About the product: Analog frequency transducer with limit value functionality and plug-in connection technology for converting standard signals into frequency or PWM signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2902032 Phoenix Contact price in the box on the right side or send a quick quote.
2902032 Product Details
- Ambient temperature (operation) -40 °C ... 70 °C
- Number of inputs 1
- Minimum switching voltage 1 V DC
- Frequency output: signal 0 Hz ... 10 kHz (via DIP switch)
- PWM output: min. load 12 mA ≤ (UL / RL) ≤ 100 mA
- PWM output: signal 15.6 kHz (10 bits, via DIP switch)
- Depth 119.2 mm
- Degree of protection IP20 (not assessed by UL)
- Voltage input signal 0 V ... 10 V (via DIP switch)
- Input resistance current input approx. 50 Ω (+0.7 V for test diode)
- Min. switching current 100 µA
- Max. input current 24 mA
- max. input voltage 12 V
- Maximum switching voltage 30 V DC
- Max. switching current 100 mA (30 V DC)
- Overrange/underrange Can be set (via software)
- Conductor cross section AWG 24 ... 12 (flexible)
- Overvoltage category II
- Height 109.81 mm
- Maximum altitude ≤ 2000 m
- Input resistance of voltage input > 120 kΩ
- Load current maximum 100 mA
- Step response (0–99%) 120 ms (15 Hz sample rate)
- Stripping length 10 mm
- No. of channels 1
- Rated insulation voltage 300 V (effective)
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Configurable/programmable Yes
- Output name Frequency output / switching output
- Frequency output: min. load 4 mA ≤ (UL / RL) ≤ 100 mA
- Nominal supply voltage 24 V DC
- Power consumption ≤ 350 mW (9.6 V DC)
- Maximum temperature coefficient < 0.01 %/K
- DNV GL-EMC A
- Certificate DNV GL TAA000021E
- ECLASS 11.0 27210120
- ECLASS 7.0 27210120
- Width 6.2 mm
- Typical current consumption 27 mA (12 V DC)
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Current input signal 0 mA ... 20 mA (via DIP switch)
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Number of outputs 1
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
- Conformance CE-compliant
- Electrical isolation Reinforced insulation in accordance with IEC 61010-1
- Temperature coefficient, typical 0.01 %/K
- Electromagnetic compatibility Conformance with EMC directive
- Noise emission EN 61000-6-4
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
- Humidity B
- ECLASS 10.0.1 27210120
- ECLASS 9.0 27210120
- UNSPSC 12.01 39121008
- Mounting position any
- DNV GL-Humidity B
- Designation Shipbuilding approval
- Temperature B
- ECLASS 4.1 27210100
- ETIM 7.0 EC002653
- UNSPSC 19.0 39121008
- EMC A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27210100
- UNSPSC 6.01 30211506
- UNSPSC 11 39121008
- Connection method Push-in connection
- Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
- UL, USA/Canada UL 508 Listed
- Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
- Conductor cross section solid 0.2 mm² ... 2.5 mm² (with ferrule)
- Degree of pollution 2
- Housing material PBT
- ATEX II 3 G Ex nA IIC T4 Gc X
- DNV GL-Vibration A
- Identification UL 508 Listed
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27210100
- ECLASS 5.1 27210100
- ETIM 4.0 EC002653
- UNSPSC 13.2 39121008
- UNSPSC 20.0 39121008
- Color gray
- Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
- DNV GL-Temperature B
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Vibration A
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 6.0 27210100
- ETIM 6.0 EC002653
- UNSPSC 7.0901 39121008
- UNSPSC 18.0 39121008
- UNSPSC 21.0 39121008
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2902032
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨