Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2838283 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2838283 PT protective connector with protective circuit for two 2-wire floating signal circuits. 24 V AC nominal voltage. HART-compatible.
Phoenix Contact

Part#:2838283

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: PT protective connector with protective circuit for two 2-wire floating signal circuits. 24 V AC nominal voltage. HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2838283 Phoenix Contact price in the box on the right side or send a quick quote.

2838283 Product Details

  • Complete module height
    90 mm
  • Flammability rating according to UL 94
    V-0
  • Nominal voltage UN
    24 V AC
  • Tightening torque
    0.5 Nm
  • Height
    44.8 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Depth
    51.7 mm
  • Degree of protection
    IP20
  • Arrester can be tested with CHECKMASTER from software version:
    From SW rev. 1.00
  • Horizontal pitch
    1 Div.
  • Altitude
    ≤ 2000 m (amsl (above mean sea level))
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Width
    17.5 mm
  • Complete module depth
    65.5 mm
  • Color
    jet black RAL 9005
  • Rated current
    450 mA (45 °C)
  • Housing material
    PA 6.6
  • Complete module width
    17.7 mm
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • IEC test classification
    C1
  • Residual current IPE
    ≤ 1 µA (with PT 2X2+F-BE)
  • Pulse discharge current Iimp (10/350) µs
    2.5 kA
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Max. discharge current Imax (8/20) µs maximum (line-earth)
    20 kA
  • Residual voltage with Ian (10/1000) µs (line-line)
    ≤ 65 V
  • Voltage protection level Up static (line-line)
    ≤ 50 V (C2 - 10 kV / 5 kA)
  • Voltage protection level Up static (line-earth)
    ≤ 50 V (C2 - 10 kV / 5 kA with PT 2X2-BE)
  • Input attenuation aE, sym.
    typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
  • Capacity (line-line)
    typ. 1.1 nF
  • Resistance per path
    2.2 Ω ±10 %
  • Max. required back-up fuse
    500 mA (T)
  • Stripping length
    8 mm
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 5.1
    27130800
  • ECLASS 6.0
    27130800
  • ETIM 2.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 18.0
    39121620
  • Mounting type
    on base element
  • Operating effective current IC at UC
    ≤ 5 µA
  • Nominal discharge current In (8/20) µs (line-line)
    10 kA
  • Nominal pulse current Ian (10/1000) µs (line-line)
    23 A
  • Output voltage limitation at 1 kV/µs (line-line) static
    ≤ 55 V
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 25 V (with PT 2X2-BE)
  • Residual voltage at In (line-line)
    ≤ 55 V
  • Voltage protection level Up (line-earth)
    ≤ 450 V (C2 - 10 kV / 5 kA with PT 2X2-BE)
  • Response time tA (line-line)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), sym. in 600 Ω system
    typ. 800 kHz
  • Surge protection fault message
    none
  • Impulse durability (line-earth)
    C2 - 10 kV / 5 kA
  • Impulse durability (line-line)
    C2 - 10 kV / 5 kA
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • REACh SVHC
    Lead 7439-92-1
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27130800
  • ECLASS 5.0
    27130800
  • ETIM 7.0
    EC000943
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 20.0
    39121620
  • Type
    Male
  • Note
    Technical data is valid in association with the following specified base elements:
  • Maximum continuous voltage UC
    40 V DC
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Max. discharge current Imax (8/20) µs maximum (line-line)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 55 V
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 450 V (with PT 2X2-BE)
  • Voltage protection level Up (line-line)
    ≤ 80 V (C2 - 10 kV / 5 kA)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 3 MHz
  • Cut-off frequency fg (3 dB), sym. in 50 Ω system
    typ. 8 MHz
  • Capacity (line-earth)
    typ. 8 pF (with PT 2X2-BE)
  • Connection method
    Screw connection (in connection with the base element)
  • Screw thread
    M3
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 10.0.1
    27130807
  • ECLASS 4.0
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 3.0
    EC000943
  • ETIM 4.0
    EC000943
  • UNSPSC 11
    39121610
  • UNSPSC 19.0
    39121620
  • ECLASS 7.0
    27130807
  • UNSPSC 7.0901
    39121610
  • UNSPSC 13.2
    39121620
  • UNSPSC 21.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2838283

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo