Product Lifecycle:Active

Get a quick Quote!

Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for four signal wires with common reference potential. Indirect grounding via gas-filled surge arrester.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2801272 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Nominal voltage UN
    24 V DC
  • Height
    109.3 mm
  • Width
    17.7 mm
  • Depth
    77.5 mm (incl. DIN rail 7.5 mm)
  • Horizontal pitch
    1 Div.
  • UNSPSC 11
    39121610
  • UNSPSC 19.0
    39121620
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Degree of protection
    IP20
  • Flammability rating according to UL 94
    V-0
  • Mounting type
    DIN rail: 35 mm
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • IEC test classification
    C1
  • Rated current
    700 mA (50 °C)
  • Residual current IPE
    ≤ 1 µA
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Voltage protection level Up static (line-earth)
    ≤ 90 V (C3 - 25 A)
  • Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω system
    typ. 1.1 MHz
  • Resistance per path
    1.2 Ω ±5 %
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-signalground)
    ≤ 350 ms
  • Conductor cross section solid
    0.5 mm² ... 4 mm²
  • Standards/specifications
    IEC 61643-21 2000 + A1:2008 + A2:2012
  • ECLASS 4.0
    27130800
  • ECLASS 5.1
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 6.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 20.0
    39121620
  • Maximum continuous voltage UC
    30 V DC
  • Nominal discharge current In (8/20) µs (line-signal ground)
    10 kA
  • Voltage protection level Up (line-earth)
    ≤ 800 V (C1 - 1 kV/500 A)
  • Response time tA (line-signalground)
    ≤ 1 ns
  • Input attenuation aE, asym.
    typ. 0.3 dB (≤ 300 kHz / 150 Ω)
  • Max. required back-up fuse
    800 mA (FF)
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • Stripping length
    10 mm
  • Conductor cross section AWG
    24 ... 12
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 10.0.1
    27130807
  • ECLASS 5.0
    27130800
  • ECLASS 6.0
    27130800
  • ETIM 3.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 12.01
    39121610
  • UNSPSC 18.0
    39121620
  • UNSPSC 21.0
    39121620
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Housing material
    PA 6.6
  • Color
    jet black RAL 9005
  • Type
    DIN rail module, two-section, divisible
  • Note
    Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
  • Operating effective current IC at UC
    ≤ 1 mA (per path)
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    2.5 kA
  • Voltage protection level Up (line-signalground)
    ≤ 75 V (C1 - 1 kV/500 A)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Capacity (line-signalground)
    typ. 2 nF
  • Surge protection fault message
    Optical, multi-stage
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Connection method
    DIN rail NS35
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 11.0
    27130807
  • ECLASS 4.1
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 4.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 13.2
    39121620

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo