2800790 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2800790 Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two signal wires with common reference potential. Indirect grounding via gas-filled surge arrester.
Phoenix Contact

Part#:2800790

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two signal wires with common reference potential. Indirect grounding via gas-filled surge arrester.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2800790 Phoenix Contact price in the box on the right side or send a quick quote.

2800790 Product Details

  • Permissible humidity (operation)
    5 % ... 95 %
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Rated current
    300 mA
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Voltage protection level Up (line-signalground)
    ≤ 105 V (C1 - 1 kV/500 A)
  • Surge protection fault message
    Optical, multi-stage
  • Pulse reset time (line-signalground)
    ≤ 1500 ms
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • ECLASS 10.0.1
    27130807
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Color
    jet black RAL 9005
  • IEC test classification
    C1
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Input attenuation aE, asym.
    typ. 0.3 dB (≤ 530 kHz / 150 Ω)
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-earth)
    ≤ 250 ms
  • Standards/specifications
    IEC 61643-21 2000 + A1:2008, modified
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27130800
  • ECLASS 5.1
    27130800
  • ETIM 4.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 21.0
    39121620
  • Width
    17.7 mm
  • Horizontal pitch
    1 Div.
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Housing material
    PA 6.6
  • Type
    DIN rail module, two-section, divisible
  • Residual current IPE
    ≤ 1 µA
  • Voltage protection level Up static (line-earth)
    ≤ 200 V (C2 - 10 kV / 5 kA)
  • Capacity (line-earth)
    typ. 1.5 nF
  • Resistance per path
    1.2 Ω ±5 %
  • Stripping length
    8 mm
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 6.0
    27130800
  • ECLASS 9.0
    27130807
  • UNSPSC 6.01
    30212010
  • UNSPSC 13.2
    39121620
  • UNSPSC 18.0
    39121620
  • Depth
    77.5 mm (incl. DIN rail 7.5 mm)
  • Degree of protection
    IP20
  • Mounting type
    DIN rail: 35 mm
  • Nominal voltage UN
    48 V DC
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    2.5 kA
  • Response time tA (line-earth)
    ≤ 100 ns
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Connection method
    DIN rail NS35
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27130800
  • ETIM 3.0
    EC000943
  • ETIM 7.0
    EC000943
  • UNSPSC 11
    39121610
  • UNSPSC 19.0
    39121620
  • Height
    91.1 mm
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Flammability rating according to UL 94
    V-0
  • Note
    Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
  • Maximum continuous voltage UC
    53 V DC
  • Operating effective current IC at UC
    ≤ 6 µA (per path)
  • Voltage protection level Up (line-earth)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-signalground)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω system
    typ. 1.9 MHz
  • Max. required back-up fuse
    315 mA (FF)
  • Screw thread
    M3
  • Tightening torque
    0.5 Nm
  • ECLASS 5.0
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 20.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo