Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2727352 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2727352 Inline power-level terminal blocks, electronic direct starter, up to 1.5 kW / 400 V AC
Phoenix Contact

Part#:2727352

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Inline power-level terminal blocks, electronic direct starter, up to 1.5 kW / 400 V AC

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2727352 Phoenix Contact price in the box on the right side or send a quick quote.

2727352 Product Details

  • Width
    63 mm
  • Permissible humidity (operation)
    10 % ... 85 % (non-condensing)
  • Degree of protection
    IP20
  • Designation
    Segment circuit supply (US)
  • Number
    1
  • Frequency range
    50 Hz ... 60 Hz
  • Overspeed tripping
    ≥ 20 A (after 0.3 seconds)
  • Current consumption
    max. 50 mA
  • Net weight
    450 g
  • Operating mode
    Process data mode with one byte
  • Mounting position
    Panel mounting on horizontal DIN rail
  • REACh SVHC
    Lead 7439-92-1
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -25 °C ... 55 °C
  • Permissible humidity (storage/transport)
    10 % ... 85 % (non-condensing)
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Number of positions
    4
  • Nominal current range
    0.2 A ... 3.6 A
  • Connection technology
    COMBICON
  • Note on weight specifications
    without plug
  • Assembly instructions
    To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50 cm both above and below.
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B; Supply lines: 2 kV; Signal/data lines: 2 kV
  • Depth
    109 mm
  • Ambient temperature (storage/transport)
    -25 °C ... 85 °C
  • Connection method
    COMBICON
  • Designation connection point
    Terminal strip X10
  • Type of contact
    Solid-state contact
  • Mounting type
    DIN rail
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, field strength: 3 V/m
  • Interference emission
    Noise emission test as per EN 61000-6-4 Radio interference properties EN 55011 Class A
  • ECLASS 4.1
    27250300
  • ECLASS 6.0
    27242600
  • UNSPSC 6.01
    43172015
  • UNSPSC 18.0
    32151602
  • Height
    224 mm
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Note
    Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
  • Transmission speed
    500 kbps
  • Permissible conductor cross section
    1 mm² ... 2.5 mm²
  • Output name
    Motor output
  • Parameterization range
    0.2 A ... 3.6 A (steps of 50/100/200 mA, via fieldbus)
  • Supply voltage
    24 V DC (via voltage jumper)
  • Power consumption
    max. 1.2 W (entire device)
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 6 kV contact discharge, criterion B, 8 kV air discharge, criterion B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27242600
  • ECLASS 11.0
    27242609
  • Transmission physics
    Copper
  • Operating voltage
    200 V AC ... 440 V AC
  • Max. current carrying capacity
    20 A
  • Switching rate
    Max. 30 per minute (observe derating)
  • Supply voltage range
    19.2 V DC ... 28.8 V DC (including all tolerances, including ripple)
  • Diagnostics messages
    Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symm./asymm.), criterion B, supply lines AC: 2 kV/4 kV (symm./asymm.)
  • ECLASS 9.0
    27242609
  • ETIM 6.0
    EC001605
  • UNSPSC 7.0901
    43201404
  • UNSPSC 13.2
    32151602
  • Protection class
    I (МЭК 61140, EN 61140, VDE 0140-1)
  • ECLASS 5.0
    27250300
  • ETIM 4.0
    EC001601
  • ETIM 7.0
    EC001605
  • UNSPSC 19.0
    32151602
  • UNSPSC 20.0
    32151602
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 2g, evaluation criterion 1
  • ECLASS 10.0.1
    27242609
  • ECLASS 4.0
    27250300
  • ECLASS 7.0
    27242609
  • ETIM 3.0
    EC001601
  • ETIM 2.0
    EC001433
  • UNSPSC 11
    43172015
  • UNSPSC 12.01
    43201404
  • UNSPSC 21.0
    32151602

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2727352

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo