2708371 Phoenix Contact Data & Networking Devices

Phoenix Contact 2708371 FO converter with integrated optical diagnostics, alarm contact, for RS-232 interfaces up to 115.2 kbps, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)
Phoenix Contact

Part#:2708371

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 1

04/16/2024

About the product: FO converter with integrated optical diagnostics, alarm contact, for RS-232 interfaces up to 115.2 kbps, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Data & Networking Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2708371 Phoenix Contact price in the box on the right side or send a quick quote.

2708371 Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Height
    99 mm
  • Altitude
    ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
  • Bit distortion, input
    ± 35 % (permitted)
  • Test voltage data interface/power supply
    1.5 kVrms (50 Hz, 1 min.)
  • MTBF
    320 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
  • Transmission length
    ≤ 15 m
  • Conductor cross section flexible max.
    2.5 mm²
  • Ambient temperature (operation)
    -20 °C ... 60 °C
  • Bit distortion, output
    < 6.25 %
  • Transmission channels
    2 (1/1), RxD, TxD, full duplex
  • Color
    green
  • Typical current consumption
    120 mA (24 V DC)
  • Transmission medium
    PCF fiber
  • Conductor cross section solid max.
    2.5 mm²
  • No. of channels
    1
  • Minimum receiver sensitivity
    -33.2 dBm
  • Number of outputs
    1
  • Certificate
    PTB 06 ATEX 2042 U
  • Temperature
    B
  • Test result
    15g, 11 ms period, half-sine shock pulse
  • Vibration
    A
  • Width
    35 mm
  • Permissible humidity (operation)
    30 % ... 95 % (non-condensing)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Net weight
    221.1 g
  • Supply voltage range
    18 V DC ... 30 V DC
  • Output name
    Relay output
  • Limiting continuous current
    0.46 A
  • Standards/regulations
    EN 61000-4-5
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27230200
  • ECLASS 4.1
    27230200
  • ETIM 3.0
    EC001423
  • ETIM 7.0
    EC001467
  • UNSPSC 11
    39121008
  • UNSPSC 20.0
    43223323
  • Depth
    105 mm
  • Degree of protection
    IP20
  • Noise emission
    EN 55011
  • Mounting type
    DIN rail mounting
  • Nominal supply voltage
    24 V DC (in acc. with UL)
  • Interface 1
    V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • Transmission protocol
    Transparent to protocol for RS-232 interface
  • Wavelength
    850 nm
  • Additional text
    Please follow the special installation instructions in the documentation!
  • EMC
    B
  • Free from substances that could impair the application of coating
    according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
  • Connection in acc. with standard
    CUL
  • Comments
    Criterion B
  • ECLASS 5.0
    27230200
  • ECLASS 4.0
    27230200
  • ECLASS 9.0
    19170114
  • UNSPSC 6.01
    30211506
  • UNSPSC 12.01
    39121008
  • Electrical isolation
    VCC // V.24 (RS-232)
  • Housing material
    PA 6.6-FR
  • Max. current consumption
    120 mA
  • Connection method
    B-FOC (ST®)
  • Conductor cross section flexible min.
    0.2 mm²
  • Identification
    DNV GL
  • Maximum switching voltage
    60 V DC
  • Designation
    Shipbuilding
  • Type of test
    Shock in acc. with EN 60068-2-27/IEC 60068-2-27
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    19170411
  • ECLASS 7.0
    19179290
  • ETIM 6.0
    EC001467
  • UNSPSC 7.0901
    39121008
  • UNSPSC 18.0
    43223323
  • UNSPSC 21.0
    43223323
  • Conductor cross section AWG max.
    14
  • Output description
    Alarm output
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Humidity
    A
  • Contact discharge
    ± 6 kV
  • ECLASS 10.0.1
    19170132
  • ECLASS 6.0
    19179200
  • ETIM 2.0
    EC001423
  • ETIM 4.0
    EC001423
  • UNSPSC 13.2
    43222604
  • UNSPSC 19.0
    43223323
  • Transmission length incl. 3 dB system reserve
    2800 m (with F-K 200/230 8 dB/km with quick mounting connector)
  • Serial transmission speed
    115.2 kbps (NRZ)
  • Noise immunity
    EN 61000-6-2:2005
  • Transmit capacity, minimum
    -4.6 dBm (200/230 µm)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 3 days!

1-year warranty

$291.65

2708371

Stock:

1

Select Qty:

$291.65

$291.65 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo