2702654 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2702654 Axioline F, Digital input module, Digital inputs: 8, 48 V DC / 60 V DC, connection method: 2-conductor, corresponds to standard IEC 61850-3, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline 
Phoenix Contact

Part#:2702654

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Axioline F, Digital input module, Digital inputs: 8, 48 V DC / 60 V DC, connection method: 2-conductor, corresponds to standard IEC 61850-3, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline 

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2702654 Phoenix Contact price in the box on the right side or send a quick quote.

2702654 Product Details

  • Width
    53.6 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Designation
    Supply for digital input modules (UI)
  • Conductor cross section AWG min.
    24
  • Mounting type
    DIN rail
  • Transmission speed
    100 Mbps
  • Description of the input
    EN 61131-2 type 1
  • ECLASS 6.0
    27242600
  • ETIM 6.0
    EC001599
  • UNSPSC 20.0
    32151602
  • Conductor cross section flexible max.
    1.5 mm²
  • Net weight
    222 g
  • Protection
    max. 8 A (for startup only)
  • Nominal input voltage UIN
    48 V DC
  • Input filter time
    < 1 ms
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Ambient temperature (operation)
    -25 °C ... 60 °C
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Mounting position
    any (no temperature derating)Nominal mounting position: wall mounting on horizontal DIN rail
  • Input voltage range
    -100 V DC ... 100 V DC
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Stripping length
    8 mm
  • Note on weight specifications
    with connectors and bus base module
  • Power consumption
    max. 600 mW
  • Number of inputs
    8
  • Input voltage range "1" signal
    32 V DC ... 100 V DC
  • Conductor cross section flexible min.
    0.2 mm²
  • Color
    traffic grey A RAL 7042
  • Number
    2
  • Current consumption
    max. 120 mA
  • Input voltage
    48 V (Nominal voltage)
  • Height
    126.1 mm
  • Connection technology
    2-conductor
  • Protective circuit
    Polarity reversal protection of the inputs
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, 20 V/m up to 1 GHz, 10 V/m up to 3 GHz
  • Test section
    I/Os / logic 4 kV Rated surge voltage (safe isolation according to EN 61010-2-201/IEC 61010-2-201)
  • Overvoltage category
    III (EN 61010-2-201/IEC 61010-2-201)
  • Depth
    54 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Connection method
    Push-in connection
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section AWG max.
    16
  • Degree of pollution
    2
  • Supply voltage
    5 V DC (via bus base module)
  • Input name
    Digital inputs
  • Input voltage range "0" signal
    -12 V DC ... 12 V DC
  • ECLASS 10.0.1
    27242604
  • ECLASS 9.0
    27242604
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Nominal input current at UIN
    2.5 mA
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, ±2 kV (symmetrical), ±4 kV (asymmetrical)
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • REACh SVHC
    Lead 7439-92-1
  • UNSPSC 19.0
    32151602
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A; 8 kV contact discharge; 8 kV air discharge
  • Developed according to standard
    IEC 61850-3 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A; 8 kV contact discharge; 8 kV air discharge
  • ECLASS 11.0
    27242604
  • UNSPSC 18.0
    32151602
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • ECLASS 7.0
    27242604
  • UNSPSC 21.0
    32151602
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ETIM 7.0
    EC001599
  • UNSPSC 13.2
    32151602
  • ECLASS 5.1
    27242604
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Conductor cross section solid min.
    0.2 mm²
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 4 kV

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo