Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2702132 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2702132 Inline XC, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, Digital inputs: 8, 24 V DC, connection method: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection method: 3-conductor, Extreme conditions version, transmission speed in the local bus
Phoenix Contact

Part#:2702132

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Inline XC, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, Digital inputs: 8, 24 V DC, connection method: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection method: 3-conductor, Extreme conditions version, transmission speed in the local bus

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2702132 Phoenix Contact price in the box on the right side or send a quick quote.

2702132 Product Details

  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.0
    27250200
  • ECLASS 6.0
    27242600
  • ETIM 7.0
    EC001604
  • UNSPSC 13.2
    32151602
  • UNSPSC 20.0
    32151602
  • Connection technology
    3-conductor
  • Nominal input current at UIN
    typ. 3 mA
  • Delay at signal change from 1 to 0
    2.9 ms
  • Output name
    Digital outputs
  • Output current when switched off
    max. 10 µA (When not loaded, a voltage can be measured even at an output that is not set.)
  • Reverse voltage resistance to short pulses
    Reverse voltage proof
  • Input voltage range "1" signal
    15 V DC ... 30 V DC
  • Nominal load, lamp
    12 W
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • ECLASS 5.0
    27250200
  • ETIM 3.0
    EC001604
  • UNSPSC 12.01
    43201404
  • Input name
    Digital inputs
  • Nominal input voltage UIN
    24 V DC
  • Number of outputs
    4
  • Nominal output voltage
    24 V DC
  • Behavior with overload
    Auto restart
  • Behavior with inductive overload
    Output can be destroyed
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
  • Interference emission
    Noise emission test as per EN 61000-6-4 EN 55011 Class A
  • ECLASS 10.0.1
    27242608
  • ECLASS 7.0
    27242608
  • ECLASS 11.0
    27242608
  • UNSPSC 7.0901
    43201404
  • UNSPSC 11
    43172015
  • UNSPSC 18.0
    32151602
  • Number of inputs
    8
  • Input voltage
    24 V DC
  • Typical input current per channel
    typ. 3 mA
  • ETIM 2.0
    EC001434
  • Delay at signal change from 0 to 1
    2.9 ms
  • Nominal load, inductive
    12 VA (1.2 H, 48 Ω)
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ECLASS 5.1
    27242600
  • ETIM 6.0
    EC001604
  • UNSPSC 19.0
    32151602
  • Power consumption
    typ. 1.7 W (entire device)
  • Protective circuit
    Short-circuit and overload protection Freewheeling circuit in the output driver
  • Nominal load, ohmic
    12 W
  • Limitation of the voltage induced on circuit interruption
    approx. -30 V
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27250200
  • ETIM 4.0
    EC001604
  • ECLASS 9.0
    27242608
  • UNSPSC 6.01
    43172015
  • Typical response time
    approx. 500 µs
  • Input voltage range "0" signal
    -30 V DC ... 5 V DC
  • Output voltage
    24 V DC -1 V (At nominal current)
  • UNSPSC 21.0
    32151602
  • Ambient temperature (operation)
    -25 °C ... 55 °C
  • Width
    80 mm
  • Note on dimensions
    Specfications with connectors
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Conductor cross section solid min.
    0.08 mm²
  • Stripping length
    8 mm
  • Diagnostics messages
    Short-circuit or overload of the digital outputs Yes
  • Number of configuration data
    max. 244 Byte (including 5 bytes for the local inputs and outputs)
  • Supply voltage
    24 V DC (via Inline connector)
  • Number of supported branch terminals with remote bus branch
    0
  • Description of the input
    EN 61131-2 type 1
  • Connection in acc. with standard
    CUL
  • Height
    119.8 mm
  • Permissible humidity (storage/transport)
    10 % ... 95 % (according to DIN EN 61131-2)
  • Degree of protection
    IP20
  • Conductor cross section AWG max.
    16
  • Conductor cross section AWG min.
    28
  • Net weight
    339.9 g
  • Number of parameter data
    max. 244 Byte (including 14 bytes for the bus coupler, DP/V1, and the local inputs and outputs)
  • Number of supported devices
    max. 63 (per station)
  • Current consumption
    min. 6 mA (without connected peripherals)
  • Depth
    71.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Connection method
    Inline connector
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • Note on weight specifications
    with connectors
  • Number of local bus devices that can be connected
    max. 61 (The on-board I/Os are two devices)
  • Number of devices with parameter channel
    max. 16
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Designation
    Segment circuit supply (US)
  • Conductor cross section flexible min.
    0.08 mm²
  • Mounting type
    DIN rail mounting
  • Color
    green
  • Amount of process data
    max. 488 Byte (per station)
  • Response time of I/Os
    typ. 4 ms (aligned I/Os; transmission speed: PROFIBUS 1.5 Mbps, local bus 500 kbps)
  • Power supply unit
    max. 8 A DC (sum of UM + US)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2702132

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo