2702071 Phoenix Contact Programmable Logic Controllers
Part#:2702071
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Checking verified in-stock parts...
About the product: Axioline F, Digital I/O module, Digital inputs: 8, 24 V DC, connection method: 3-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 2702071 Phoenix Contact price in the box on the right side or send a quick quote.
2702071 Product Details
- Width 35 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Designation Supply for digital input and output modules (UIO)
- Color traffic grey A RAL 7042
- Depth 54 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Degree of protection IP20
- Conductor cross section solid min. 0.2 mm²
- Caption Dimensions
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Conductor cross section flexible min. 0.2 mm²
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Connection method Push-in connection
- Conductor cross section AWG min. 24
- Net weight 159 g
- Input name Digital inputs
- Height 129.9 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section solid max. 1.5 mm²
- Protection max. 8 A (polarity reversal protection up to 5 A)
- Number of inputs 8
- Mounting position any (no temperature derating)
- Current consumption max. 6 A (provide external protection)
- Input filter time 3000 µs (Default)
- Conductor cross section flexible max. 1.5 mm²
- Stripping length 8 mm
- Number of interfaces 2
- Supply voltage 24 V DC
- Mounting type DIN rail
- Note on weight specifications with connectors and bus base module
- Connection technology 3-conductor
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Description of the input EN 61131-2 types 1 and 3
- Input voltage range "0" signal -3 V DC ... 5 V DC
- ECLASS 11.0 27242604
- Transmission speed 100 Mbps
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Nominal input voltage UIN 24 V DC
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 5.1 27242600
- ECLASS 7.0 27242604
- Conductor cross section AWG max. 16
- Power consumption max. 180 W (of which 1.24 W internal losses)
- Nominal input current at UIN 2.4 mA
- Number of outputs 8
- Protective circuit Short-circuit protection, overload protection of the outputs electronic
- Nominal output voltage 24 V DC
- Output voltage when switched off max. 1 V
- Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- REACh SVHC Lead 7439-92-1
- ECLASS 6.0 27242600
- UNSPSC 18.0 32151602
- UNSPSC 21.0 32151602
- Output name Digital outputs
- Nominal load, inductive max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Load min. 10 kΩ
- Behavior with inductive overload Output can be destroyed
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 10.0.1 27242604
- ETIM 7.0 EC001599
- ETIM 6.0 EC001599
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Nominal load, ohmic max. 12 W (48 Ω, with nominal voltage)
- Behavior with overload Shutdown with automatic restart
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 9.0 27242604
- UNSPSC 19.0 32151602
- Output voltage 24 V DC
- Nominal load, lamp max. 12 W (at nominal voltage)
- Switching frequency max. 10000 per second (with at least 50 mA load current)
- Output current when switched off max. 300 µA
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- UNSPSC 13.2 32151602
- UNSPSC 20.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨