2702052 Phoenix Contact Programmable Logic Controllers
Part#:2702052
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Axioline F, Digital input module, Digital inputs: 32, 24 V DC, connection method: 1-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2702052 Phoenix Contact price in the box on the right side or send a quick quote.
2702052 Product Details
- Designation Supply for digital input modules (UI)
- Current consumption max. 50 mA
- Degree of protection IP20
- Conductor cross section solid min. 0.2 mm²
- Description of the input EN 61131-2 types 1 and 3
- Transmission speed 100 Mbps
- ECLASS 9.0 27242604
- ECLASS 6.0 27242600
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- Protection max. 8 A (polarity reversal protection up to 5 A)
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Input filter time 3000 µs (Default)
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- REACh SVHC Lead 7439-92-1
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 7.0 27242604
- ETIM 7.0 EC001599
- Conductor cross section solid max. 1.5 mm²
- Net weight 159 g
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Number of inputs 32
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Conductor cross section flexible max. 1.5 mm²
- Stripping length 8 mm
- Power consumption max. 1.2 W
- Connection technology 1-conductor
- Input voltage range "0" signal -3 V DC ... 5 V DC
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- ECLASS 10.0.1 27242604
- ECLASS 5.1 27242600
- UNSPSC 19.0 32151602
- UNSPSC 13.2 32151602
- UNSPSC 21.0 32151602
- Number of interfaces 2
- Protective circuit Polarity reversal protection of the inputs parallel diode (30 V, 5 s)
- Input name Digital inputs
- Nominal input voltage UIN 24 V DC
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27242604
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ETIM 6.0 EC001599
- UNSPSC 18.0 32151602
- Mounting position any (no temperature derating)
- Depth 54 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Mounting type DIN rail
- Width 35 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Conductor cross section AWG min. 24
- Supply voltage 24 V DC
- Nominal input current at UIN 2.4 mA
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section flexible min. 0.2 mm²
- Color traffic grey A RAL 7042
- Note on weight specifications with connectors and bus base module
- Height 129.9 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Caption Dimensions
- UNSPSC 20.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2702052
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide