2702017 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2702017 Axioline F XC, Digital I/O module, Digital inputs: 8, 24 V DC, connection method: 1-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 1-conductor, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protec
Phoenix Contact

Part#:2702017

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 17

04/19/2024

About the product: Axioline F XC, Digital I/O module, Digital inputs: 8, 24 V DC, connection method: 1-conductor, Digital outputs: 8, 24 V DC, 500 mA, connection method: 1-conductor, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protec

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2702017 Phoenix Contact price in the box on the right side or send a quick quote.

2702017 Product Details

  • Output name
    Digital outputs
  • Input voltage range "0" signal
    -3 V DC ... 5 V DC
  • Output voltage
    24 V DC
  • Nominal load, ohmic
    max. 12 W (48 Ω, with nominal voltage)
  • Load min.
    10 kΩ
  • Ambient temperature (operation)
    -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Conductor cross section solid max.
    1.5 mm²
  • Color
    traffic grey A RAL 7042
  • Transmission speed
    100 Mbps
  • Current consumption
    max. 4 A (provide external protection)
  • Description of the input
    EN 61131-2 types 1 and 3
  • Nominal input voltage UIN
    24 V DC
  • Mounting type
    DIN rail
  • Supply voltage
    24 V DC
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Input name
    Digital inputs
  • Protection
    max. 8 A (polarity reversal protection up to 5 A)
  • Reverse voltage resistance to short pulses
    limited protection up to 0.5 A for 1 s
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Connection method
    Push-in connection
  • Conductor cross section flexible min.
    0.2 mm²
  • Number of outputs
    8
  • Input voltage range "1" signal
    11 V DC ... 30 V DC
  • Switching frequency
    max. 10000 per second (with at least 50 mA load current)
  • Conductor cross section AWG min.
    24
  • Net weight
    133 g
  • Note on weight specifications
    with connectors and bus base module
  • Overvoltage category
    II (IEC 60664-1, EN 60664-1)
  • ETIM 6.0
    EC001599
  • UNSPSC 20.0
    32151602
  • Power consumption
    max. 96 W (of which 1.35 W internal losses)
  • Protective circuit
    Short-circuit protection, overload protection of the outputs electronic
  • Depth
    54 mm
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Number of inputs
    8
  • Nominal input current at UIN
    2.4 mA
  • Nominal output voltage
    24 V DC
  • Output voltage when switched off
    max. 1 V
  • Behavior with inductive overload
    Output can be destroyed
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Designation
    Supply for digital input and output modules (UIO)
  • Conductor cross section flexible max.
    1.5 mm²
  • Behavior with overload
    Shutdown with automatic restart
  • ATEX
     II 3 G Ex ec IIC T4 Gc
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27242600
  • UNSPSC 13.2
    32151602
  • Degree of pollution
    2 (IEC 60664-1, EN 60664-1)
  • Mounting position
    any (no temperature derating)
  • Number of interfaces
    2
  • Width
    35 mm
  • Height
    126.1 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Connection technology
    1-conductor
  • Input filter time
    3000 µs (Default)
  • Nominal load, lamp
    max. 12 W (at nominal voltage)
  • Nominal load, inductive
    max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
  • Output current when switched off
    max. 300 µA
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Stripping length
    8 mm
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 7.0
    27242604
  • ECLASS 6.0
    27242600
  • UNSPSC 18.0
    32151602
  • UNSPSC 21.0
    32151602
  • Test section
    5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
  • IECEx
    Ex ec IIC T4 Gc
  • ECLASS 10.0.1
    27242604
  • ETIM 7.0
    EC001599
  • UNSPSC 19.0
    32151602
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • UL, USA/Canada
    cULus
  • ECLASS 9.0
    27242604
  • ECLASS 11.0
    27242604

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$329.77

2702017

Stock:

17

Select Qty:

$329.77

$329.77 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo