Welcome to Quotebeam
Nikki Gonzales
Bryan Obida
Nick Goetz

Live support:

Monday - Friday 6AM - 6PM PST

2701722 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2701722 Axioline F, Digital input module, Digital inputs: 16, 24 V DC, connection method: 1-conductor, Input filter time < 5 µs, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Phoenix Contact

Part#:2701722

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Axioline F, Digital input module, Digital inputs: 16, 24 V DC, connection method: 1-conductor, Input filter time < 5 µs, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2701722 Phoenix Contact price in the box on the right side or send a quick quote.

2701722 Product Details

  • Connection technology
    1-conductor
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • REACh SVHC
    Lead 7439-92-1
  • Number of interfaces
    2
  • Protective circuit
    Polarity reversal protection of the inputs parallel diode (30 V, 5 s)
  • ECLASS 11.0
    27242604
  • ECLASS 4.1
    27240400
  • ETIM 7.0
    EC001599
  • UNSPSC 11
    39121311
  • Number of inputs
    16
  • ETIM 4.0
    EC001596
  • UNSPSC 6.01
    43172015
  • UNSPSC 13.2
    32151602
  • Current consumption
    max. 30 mA
  • Input name
    Digital inputs
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Overvoltage category
    II (IEC 60664-1, EN 60664-1)
  • ECLASS 4.0
    27240400
  • ECLASS 6.0
    27242600
  • UNSPSC 12.01
    39121311
  • UNSPSC 18.0
    32151602
  • Input filter time
    < 5 µs
  • ECLASS 5.1
    27242600
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Note on weight specifications
    with connectors and bus base module
  • Supply voltage
    24 V DC
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Conductor cross section AWG min.
    24
  • Net weight
    133 g
  • Nominal input voltage UIN
    24 V DC
  • Input voltage range "0" signal
    -3 V DC ... 8.4 V DC
  • ECLASS 5.0
    27242200
  • Conductor cross section flexible max.
    1.5 mm²
  • Mounting type
    DIN rail
  • Transmission speed
    100 Mbps
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Nominal input current at UIN
    2.3 mA
  • ECLASS 9.0
    27242604
  • Conductor cross section solid max.
    1.5 mm²
  • Stripping length
    8 mm
  • Degree of pollution
    2 (IEC 60664-1, EN 60664-1)
  • Power consumption
    max. 720 mW
  • Description of the input
    EN 61131-2 types 1 and 3
  • Input voltage range "1" signal
    9.4 V DC ... 30 V DC
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
  • ECLASS 7.0
    27242604
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Conductor cross section flexible min.
    0.2 mm²
  • Color
    traffic grey A RAL 7042
  • Mounting position
    any (no temperature derating)
  • ECLASS 10.0.1
    27242604
  • Width
    35 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Designation
    Supply for digital input modules (UI)
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Depth
    54 mm
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Connection method
    Push-in connection
  • Caption
    Dimensions
  • Ambient temperature (operation)
    -25 °C ... 60 °C
  • Height
    126.1 mm
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Protection
    max. 8 A (polarity reversal protection up to 5 A)
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • ETIM 3.0
    EC001045
  • ETIM 6.0
    EC001599
  • UNSPSC 21.0
    32151602
  • Test section
    5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • UNSPSC 20.0
    32151602
  • UNSPSC 7.0901
    43201404
  • UNSPSC 19.0
    32151602

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo