2701536 Phoenix Contact Programmable Logic Controllers
Part#:2701536
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Checking verified in-stock parts...
About the product: Axioline E-Ethernet device in a plastic housing with 8 IO-Link ports and 4 digital inputs, 24 V DC, M12 fast connection technology
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 2701536 Phoenix Contact price in the box on the right side or send a quick quote.
2701536 Product Details
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- China RoHS Environmentally Friendly Use Period = 25;
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Number of inputs max. 8 (EN 61131-2 type 1)
- Nominal input current typ. 3 mA
- Number of outputs max. 8
- Nominal output voltage 24 V DC
- Output voltage when switched off max. 1 V
- ECLASS 11.0 27242604
- ECLASS 5.0 27242200
- UNSPSC 7.0901 43201404
- ETIM 4.0 EC001599
- UNSPSC 6.01 43172015
- UNSPSC 13.2 32151602
- Permissible humidity (storage/transport) 5 % ... 95 %
- Degree of protection IP65/IP67
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Input voltage range "1" signal 15 V DC ... 30 V DC
- Input frequency 0.5 kHz
- Maximum output current per channel 150 mA
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Input voltage range "0" signal -0.3 V DC ... 5 V DC
- Total sensor current max. 1.6 A (from L+/L-)
- Output description IO-Link ports in digital output (DO) mode
- Nominal load, ohmic 3.6 W (160 Ω, at nominal load)
- Signal delay max. 150 µs (when switched on)
- Test section 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- UNSPSC 12.01 39121311
- UNSPSC 19.0 32151602
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Net weight 554.3 g
- Nominal input current at UIN typ. 3 mA
- ETIM 6.0 EC001599
- UNSPSC 21.0 32151602
- UNSPSC 18.0 32151602
- Permissible humidity (operation) 5 % ... 95 %
- Color anthracite
- Transmission speed 10/100 Mbps (with auto negotiation)
- Nominal input voltage UIN 24 V DC
- Sensor current per channel max. 200 mA (from L+/L-)
- Maximum output current per device 1.2 A
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27242600
- ECLASS 6.0 27242600
- Designation Actuators (UA)
- Equipment type Modbus slave (server)
- Input name Digital inputs at pin 2 for type A ports
- Input filter time < 1000 µs
- Output current when switched off max. 300 µA
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- ECLASS 4.0 27240400
- ETIM 7.0 EC001599
- UNSPSC 11 39121311
- UNSPSC 20.0 32151602
- Nominal load, inductive 3.6 VA (0.8 H, 160 Ω, at nominal load)
- ETIM 3.0 EC001599
- Connection technology 3-conductor
- Height 185 mm
- Drill hole spacing 198.5 mm
- Switching rate 1 per second, maximum (at nominal inductive load)
- ETIM 2.0 EC001433
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Number 2
- Description of the input IO-Link ports in digital input (DI) mode
- Behavior with overload Shutdown with automatic restart
- ECLASS 7.0 27242604
- ECLASS 9.0 27242604
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ECLASS 4.1 27240400
- Specification Modbus application protocol V1.1b
- Supply voltage 24 V DC
- Number of positions 4
- Housing material Pocan®
- Depth 30.5 mm
- Note on dimensions The height is 212 mm including fixing clips.
- Mounting type Wall mounting
- Designation connection point Copper cable
- System-specific protocols Modbus protocols Modbus/TCP
- Ambient temperature (operation) -25 °C ... 60 °C
- Note on the connection method D-coded
- Width 60 mm
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Current consumption typ. 28 mA ±15 % (at 24 V DC)
- Type of protection Overload protection
- Limitation of the voltage induced on circuit interruption -15 V DC
- ECLASS 10.0.1 27242604
- Connection method M12 connector, X01 ... X04 have double occupancy
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Protocols supported SNMP v1
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨