2701495 Phoenix Contact Programmable Logic Controllers
Part#:2701495
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Axioline E, Digital I/O device, EtherNet/IP™, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-conductor, Digital outputs: 4, 24 V DC, 2 A, connection method: 3-conductor, Plastic housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701495 Phoenix Contact price in the box on the right side or send a quick quote.
2701495 Product Details
- Housing material Pocan®
- Note on the connection method D-coded
- Transmission speed 10/100 Mbps (with auto negotiation)
- Input name Digital inputs
- Protective circuit Overload protection, short-circuit protection of outputs yes
- Width 60 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Input filter time < 1000 µs
- Output name Digital outputs
- Nominal output voltage 24 V DC (from voltage UA)
- Output voltage when switched off max. 1 V
- Note on dimensions The height is 212 mm including fixing clips.
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Degree of protection IP65/IP67
- Net weight 552 g
- Equipment type EtherNet/IP™ slave
- Specification CIP Edition 3.11EIP adaptation of CIP 1.12
- Nominal input current at UIN typ. 3 mA
- Cable length max. 30 m (To the sensor)
- Nominal load, inductive 48 VA (1.2 H, 48 Ω, with nominal voltage)
- Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 10.0.1 27242604
- ECLASS 6.0 27242600
- ETIM 3.0 EC001599
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 5 % ... 95 %
- Mounting type Wall mounting
- Color anthracite
- Designation connection point Copper cable
- Current consumption typ. 30 mA ±15 % (at 24 V DC)
- Connection technology 3-conductor
- Input voltage range "0" signal 0 V ... 5 V DC
- Number of outputs 4
- Output current when switched off max. 20 µA
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27240400
- ECLASS 11.0 27242604
- ETIM 7.0 EC001599
- UNSPSC 13.2 32151602
- UNSPSC 21.0 32151602
- Depth 30.5 mm
- Drill hole spacing 198.5 mm
- Permissible humidity (storage/transport) 5 % ... 95 %
- Number 2
- Connection method M12 connector, (A-coded)
- Reverse voltage resistance to short pulses Reverse voltage proof
- Protocols supported SNMP v1
- Description of the input EN 61131-2 types 1 and 3
- Nominal input voltage UIN 24 V DC
- Output voltage 24 V DC
- Nominal load, ohmic 48 W (48 Ω, with nominal voltage)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.1 27242600
- ETIM 2.0 EC001433
- ETIM 4.0 EC001599
- ECLASS 5.0 27242200
- ECLASS 9.0 27242604
- ETIM 6.0 EC001599
- UNSPSC 7.0901 43201404
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27240400
- ECLASS 7.0 27242604
- UNSPSC 11 39121311
- UNSPSC 6.01 43172015
- UNSPSC 19.0 32151602
- Number of inputs 8
- Height 185 mm
- Behavior with overload Auto restart
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Number of positions 4
- Supply voltage 24 V DC
- System-specific protocols EtherNet/IP™ protocols ACD
- Ambient temperature (operation) -25 °C ... 60 °C
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Designation Actuators (UA)
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Switching frequency max. 5500 per second (with at least 50 mA load current)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- UNSPSC 12.01 39121311
- UNSPSC 18.0 32151602
- UNSPSC 20.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2701495
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨