2701491 Phoenix Contact Programmable Logic Controllers
Part#:2701491
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 2
04/18/2024
About the product: Axioline E, EtherNet/IP™, M12 fast connection technology, Digital inputs at pin 2 for type A ports: 4, 24 V DC, connection method: 3-conductor, Metal housing, degree of protection: IP65/IP67
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2701491 Phoenix Contact price in the box on the right side or send a quick quote.
2701491 Product Details
- Supply voltage 24 V DC
- Protocols supported SNMP v1
- Description of the input IO-Link ports in digital input (DI) mode
- Nominal input voltage UIN 24 V DC
- Nominal input current typ. 3 mA
- Transmission speed 10/100 Mbps (with auto negotiation)
- System-specific protocols EtherNet/IP™ protocols ACD
- Connection technology 3-conductor
- Input voltage range "0" signal -0.3 V DC ... 5 V DC
- Number of outputs max. 8
- Total sensor current max. 1.6 A (from L+/L-)
- Nominal load, inductive 3.6 VA (0.8 H, 160 Ω, at nominal load)
- Behavior with overload Shutdown with automatic restart
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ECLASS 6.0 27242600
- UNSPSC 21.0 32151602
- Maximum output current per channel 150 mA
- Designation connection point Copper cable
- Specification CIP Edition 3.11EIP adaptation of CIP 1.12
- Protective circuit Overload protection, short-circuit protection of sensor supply
- Type of protection Overload protection
- Input frequency 0.5 kHz
- Signal delay max. 150 µs (when switched on)
- Current consumption typ. 28 mA ±15 % (at 24 V DC)
- Output current when switched off max. 300 µA
- ECLASS 10.0.1 27242604
- ECLASS 11.0 27242604
- ECLASS 5.1 27242600
- ETIM 4.0 EC001599
- UNSPSC 11 39121311
- UNSPSC 20.0 32151602
- Note on the connection method D-coded
- Number of positions 4
- Input name Digital inputs at pin 2 for type A ports
- Number of inputs max. 8 (EN 61131-2 type 1)
- Input voltage range "1" signal 15 V DC ... 30 V DC
- Sensor current per channel max. 200 mA (from L+/L-)
- Nominal load, ohmic 3.6 W (160 Ω, at nominal load)
- Switching rate 1 per second, maximum (at nominal inductive load)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ECLASS 4.1 27240400
- ECLASS 7.0 27242604
- ETIM 3.0 EC001599
- Designation Actuators (UA)
- Equipment type EtherNet/IP™ slave
- Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
- Limitation of the voltage induced on circuit interruption -15 V DC
- Output voltage when switched off max. 1 V
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ETIM 2.0 EC001433
- UNSPSC 6.01 43172015
- Maximum output current per device 1.2 A
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27242200
- ECLASS 9.0 27242604
- ETIM 7.0 EC001599
- UNSPSC 12.01 39121311
- Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Housing material Zinc die-cast
- Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
- Test section 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
- Depth 38 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Permissible humidity (storage/transport) 5 % ... 95 %
- Number 2
- Width 60 mm
- Drill hole spacing 198.5 mm
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- ETIM 6.0 EC001599
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 5 % ... 95 %
- Degree of protection IP65/IP67
- Connection method M12 connector, X01 ... X04 have double occupancy
- UNSPSC 7.0901 43201404
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Net weight 721 g
- Nominal output voltage 24 V DC
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
- Height 185 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- UNSPSC 19.0 32151602
- Input filter time < 1000 µs
- ECLASS 4.0 27240400
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- UNSPSC 13.2 32151602
- Nominal input current at UIN typ. 3 mA
- Output description IO-Link ports in digital output (DO) mode
- UNSPSC 18.0 32151602
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
This item can ship within 24h!
1-year warranty
$611.05
2701491
Stock:
2
Select Qty:
$611.05
$611.05 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨