Welcome to Quotebeam
Nikki Gonzales
Bryan Obida
Nick Goetz

Live support:

Monday - Friday 6AM - 6PM PST

2701457 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2701457 Axioline F, Bus coupler, Ethernet (IEC 61850, MMS, GOOSE), RJ45 jack, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector
Phoenix Contact

Part#:2701457

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Axioline F, Bus coupler, Ethernet (IEC 61850, MMS, GOOSE), RJ45 jack, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2701457 Phoenix Contact price in the box on the right side or send a quick quote.

2701457 Product Details

  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Supply voltage
    5 V DC (via bus base module)
  • Type of protection
    Surge protection
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Degree of protection
    IP20
  • Conductor cross section flexible max.
    1.5 mm²
  • Net weight
    177 g
  • Transmission physics
    Ethernet in RJ45 twisted pair
  • Height
    126.1 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail)
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Connection method
    Micro USB type B
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Mounting type
    DIN rail mounting
  • Degree of pollution
    2 (IEC 60664-1, EN 60664-1)
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Transmission speed
    100 Mbps
  • Power consumption
    max. 13.7 W (2.0 A on UBus, UL = 24 V)
  • Width
    45 mm
  • ECLASS 5.0
    27242200
  • ETIM 4.0
    EC001604
  • ECLASS 9.0
    27242608
  • UNSPSC 7.0901
    43201404
  • UNSPSC 20.0
    32151602
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Conductor cross section AWG min.
    24
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Note on the connection method
    Auto negotiation and autocrossing
  • Stripping length
    8 mm
  • Number of interfaces
    1
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • REACh SVHC
    Lead 7439-92-1
  • Mounting position
    any (observe temperature derating)
  • Number of supported devices
    max. 63 (per station)
  • Current consumption
    max. 570 mA (with 2 A at UBus for the I/Os and UL = 24 V)
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Depth
    74 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Designation
    Axioline F local bus supply (UBus)
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Note on weight specifications
    with connector and bus base module
  • Protocol
    MMS
  • Number of local bus devices that can be connected
    max. 63
  • Power supply unit
    2 A
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
  • Color
    traffic grey A RAL 7042
  • Overvoltage category
    II (IEC 60664-1, EN 60664-1)
  • ECLASS 10.0.1
    27242608
  • ECLASS 6.0
    27242600
  • UNSPSC 6.01
    43172015
  • ETIM 7.0
    EC001604
  • UNSPSC 19.0
    32151602
  • UNSPSC 18.0
    32151602
  • UNSPSC 13.2
    32151602
  • ECLASS 7.0
    27242608
  • ECLASS 4.0
    27240400
  • ECLASS 5.1
    27242600
  • UNSPSC 11
    39121311
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • ECLASS 4.1
    27240400
  • ECLASS 11.0
    27242608
  • ETIM 3.0
    EC001604
  • UNSPSC 21.0
    32151602
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • ETIM 6.0
    EC001604
  • UNSPSC 12.01
    39121311

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo