2701295 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2701295 Axiocontrol for the direct control of Axioline I/Os. With 2 Ethernet interfaces, extended temperature range, and programming options according to IEC 61131-3. Complete with connector connector and marking field.
Phoenix Contact

Part#:2701295

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Axiocontrol for the direct control of Axioline I/Os. With 2 Ethernet interfaces, extended temperature range, and programming options according to IEC 61131-3. Complete with connector connector and marking field.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2701295 Phoenix Contact price in the box on the right side or send a quick quote.

2701295 Product Details

  • Air pressure (storage/transport)
    58 kPa ... 106 kPa (up to 4500 m above mean sea level)
  • Shock
    30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
  • Program memory
    2 Mbyte
  • Number of control tasks
    8
  • Number of local bus devices that can be connected
    max. 63 (observe current consumption)
  • Specification
    Version 2.3
  • Width
    45 mm
  • Configuration tool
    Config+ Version 1.01 or later
  • Accuracy realtime clock
    1.73 s/day = 20 ppm at 25 °C
  • Interface
    Service
  • Number
    1
  • Max. current consumption
    160 mA
  • Safety function
    No
  • Number of supported devices
    max. 63 (per station)
  • Device function
    PROFINET controller, PROFINET device
  • Supply voltage range
    19.2 V DC ... 30 V DC
  • Power dissipation
    max. 3 W
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • ECLASS 10.0.1
    27242207
  • UNSPSC 19.0
    39122114
  • Vibration (operation)
    5g
  • Retentive mass storage
    48 kByte (NVRAM)
  • Diagnostics tool
    DIAG+
  • Amount of process data
    max. 8192 Bit (per station)
  • Transmission speed
    max. 115.2 kbps
  • Realtime clock
    Yes
  • Residual ripple
    ± 5 %
  • Note on weight specifications
    with connector and bus base module
  • Diagnostics display
    No
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Vibration (storage/transport)
    5g
  • Depth
    74 mm
  • Engineering tool
    PC WORX
  • Programming languages supported
    Programming in acc. with IEC 61131-3
  • Mass storage
    2 Mbyte
  • Connection method
    Micro USB type B
  • Typical current consumption
    125 mA
  • Supply voltage
    24 V DC
  • Processor
    Altera Nios II 1x 100 MHz
  • Shock (operation)
    10g (Bump endurance test according to DIN EN 60068-2-27)
  • UNSPSC 21.0
    39122114
  • Weight
    195 g
  • Controller redundancy
    No
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • ECLASS 4.0
    27240600
  • ECLASS 5.1
    27242700
  • ECLASS 7.0
    27242207
  • UNSPSC 6.01
    81111810
  • Update rate
    min. 32 ms (16 devices)
  • UNSPSC 13.2
    39122114
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Ambient temperature (operation)
    -40 °C ... 70 °C up to 2000 m above mean sea level (observe derating)
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Degree of protection
    IP20
  • Permissible humidity (operation)
    5 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
  • Height
    126.1 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27240600
  • ETIM 3.0
    EC001045
  • ETIM 7.0
    EC000236
  • UNSPSC 18.0
    39122114
  • ETIM 6.0
    EC000236
  • UNSPSC 12.01
    81111810
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • ECLASS 5.0
    27242700
  • ETIM 4.0
    EC001435
  • UNSPSC 7.0901
    81111810
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
  • ECLASS 11.0
    27242207
  • ECLASS 6.0
    27242200
  • ECLASS 9.0
    27242207
  • UNSPSC 11
    81111810
  • UNSPSC 20.0
    39122114

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo