2692380 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2692380 Inline, Bus coupler, Sercos, RJ45 jack, Digital inputs: 8, 24 V DC, connection method: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection method: 3-conductor, transmission speed in the local bus: 500 kbps / 2 Mbps, degree of protection: IP20, in
Phoenix Contact

Part#:2692380

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Inline, Bus coupler, Sercos, RJ45 jack, Digital inputs: 8, 24 V DC, connection method: 3-conductor, Digital outputs: 4, 24 V DC, 500 mA, connection method: 3-conductor, transmission speed in the local bus: 500 kbps / 2 Mbps, degree of protection: IP20, in

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2692380 Phoenix Contact price in the box on the right side or send a quick quote.

2692380 Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -25 °C ... 60 °C
  • Note on weight specifications
    with connectors
  • Connection method
    Inline connector
  • Equipment type
    Sercos slave
  • Power supply unit
    max. 8 A DC (sum of UM + US)
  • Connection technology
    3-conductor
  • Protective circuit
    Short-circuit and overload protection Freewheeling circuit in the output driver
  • Output voltage
    24 V DC -1 V (At nominal current)
  • Depth
    71.5 mm
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Mounting type
    DIN rail mounting
  • Net weight
    298 g
  • Number of devices with parameter channel
    max. 16
  • Supply voltage
    24 V DC (via Inline connector)
  • Power consumption
    typ. 3.2 W (entire device)
  • Typical response time
    approx. 500 µs
  • Input voltage range "0" signal
    -30 V DC ... 5 V DC
  • Nominal load, lamp
    12 W
  • Nominal load, ohmic
    12 W
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • Permissible humidity (storage/transport)
    10 % ... 95 % (non-condensing)
  • Designation
    Segment circuit supply (US)
  • Amount of process data
    max. 512 Byte (per station)
  • Transmission speed
    500 kbps / 2 Mbps (automatic detection, no combined system)
  • Number of supported branch terminals with remote bus branch
    0
  • Nominal input voltage UIN
    24 V DC
  • Nominal input current at UIN
    typ. 3 mA
  • Number of outputs
    4
  • Nominal output voltage
    24 V DC
  • ECLASS 7.0
    27242608
  • Width
    80 mm
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Note on dimensions
    Specfications with connectors
  • Color
    green
  • Number of local bus devices that can be connected
    max. 61 (The on-board I/Os are two devices)
  • Device profile
    FSP_IO
  • Current consumption
    min. 3 mA (without actuators)
  • Input name
    Digital inputs
  • Input voltage
    24 V DC
  • Typical input current per channel
    typ. 3 mA
  • Output voltage when switched off
    max. 500 mV
  • Reverse voltage resistance to short pulses
    Reverse voltage proof
  • Interference emission
    Noise emission test as per EN 61000-6-4 Class A
  • ECLASS 10.0.1
    27242608
  • ECLASS 5.0
    27250300
  • ETIM 4.0
    EC001599
  • UNSPSC 12.01
    43201404
  • Height
    119.8 mm
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Degree of protection
    IP20
  • Diagnostics messages
    Short-circuit or overload of the digital outputs Yes
  • Number
    2
  • Number of supported devices
    max. 63 (per station)
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Description of the input
    EN 61131-2 type 1
  • Number of inputs
    8
  • Input voltage range "1" signal
    15 V DC ... 30 V DC
  • Output name
    Digital outputs
  • Output current when switched off
    max. 500 µA (When not loaded, a voltage can be measured even at an output that is not set.)
  • ECLASS 5.1
    27242600
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • ECLASS 11.0
    27242608
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.0
    27250300
  • ECLASS 9.0
    27242608
  • ETIM 7.0
    EC001604
  • UNSPSC 19.0
    32151602
  • UNSPSC 18.0
    32151602
  • Behavior with inductive overload
    Output can be destroyed
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ETIM 3.0
    EC001599
  • Nominal load, inductive
    12 VA (1.2 H, 48 Ω)
  • Limitation of the voltage induced on circuit interruption
    approx. -30 V
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
  • ECLASS 6.0
    27242600
  • UNSPSC 6.01
    43172015
  • UNSPSC 11
    43172015
  • UNSPSC 20.0
    32151602
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
  • UNSPSC 7.0901
    43201404
  • UNSPSC 21.0
    32151602
  • ECLASS 4.1
    27250300
  • ETIM 6.0
    EC001604
  • UNSPSC 13.2
    32151602
  • Behavior with overload
    Auto restart
  • REACh SVHC
    1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
  • ETIM 2.0
    EC001430

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo